Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,695 models

Sorted by manufacturer and model.
Page 50 of 388
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
122625VNA836A*032*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**4321AL*+UI and furnace 58TN*A090C17**16Carrier3 tons34,000 Btu/h · Ducted1.9858%8.116.59.519,100None593206764622
122725VNA837A*030*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CNPV*4221AL*+UI and furnace 58TN*A090C21**20Carrier2.5 tons31,800 Btu/h · Ducted2.1083%7.517.011.027,400CEE 25CEE 26Xcel591204299595
122825VNA837A*030*+TSTATCARRIER · INFINITY 18VS HEAT PUMP 2-STAGEwith indoor coil CAP**3721AL and furnace 58SP*B090V21**20Carrier3 tons33,000 Btu/h · Ducted2.0052%8.515.511.025,000CEE 25CEE 26716214378785
122925VNA837A*031*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**6124AL*+UI and furnace 59CU5A100C21**22Carrier3 tons33,200 Btu/h · Ducted2.0278%8.518.011.524,800CEE 25CEE 26Xcel608210470528
123025VNA837A*031*+TSTATCARRIERwith ducted air handler F,PE*SS9937Carrier2.5 tons30,400 Btu/h · Ducted2.0454%8.516.011.024,000CEE 25CEE 261,096211756887
123125VNA848A*030*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CSPH*4812AL*+UI and furnace 58TN*A135C24**22Carrier4 tons45,500 Btu/h · Ducted2.0864%8.516.510.030,000CEE 25180204301453
123225VNA848A*030*+TSTATCARRIER · INFINITY 18VS HEAT PUMP 2-STAGEwith indoor coil CAP**4821AL and furnace 58SP*B090V21**20Carrier4 tons45,000 Btu/h · Ducted1.8047%7.514.59.525,600None62214377454
123325VNA848A*031*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CSPH*4812AL*+UI and furnace 58TN*A135C24**22Carrier4 tons45,500 Btu/h · Ducted2.0864%8.516.510.030,000CEE 25204206765255
123425VNA848A*031*+TSTATCARRIER · INFINITY 18VS HEAT PUMP 2-STAGEwith ducted air handler FV4CN(B,F)005LCarrier4 tons46,000 Btu/h · Ducted1.8248%7.716.010.525,200None39206765167
123525VNA860A*030*+TSTATCARRIER · INFINITY 18VS HEAT PUMP 2-STAGEwith ducted air handler FV4CNB006LCarrier4.5 tons56,500 Btu/h · Ducted1.8852%8.014.59.534,400None610461080
123625VNA860A*031*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**6124AL*+UI and furnace 58TN*A090C21**20Carrier4.5 tons56,000 Btu/h · Ducted1.8458%8.116.59.535,200None125206765321
123725VNA860A*031*+TSTATCARRIER · INFINITY 18VS HEAT PUMP 2-STAGEwith ducted air handler FV4CNB006LCarrier4.5 tons56,500 Btu/h · Ducted1.8852%8.014.59.534,400None21206765313
1238284ANV024*0**B*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**3721AL*+UI and furnace 88*TA48090C17Carrier2 tons24,200 Btu/h · Ducted2.5874%11.021.514.019,600CEE 25CEE 26Xcel410210533009
1239284ANV036*0**B*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION Extreme 24 HPwith ducted air handler FE4ANB006L+UICarrier3 tons34,800 Btu/h · Ducted2.0670%9.520.513.024,800CEE 25CEE 26XcelES CC613206790264
1240284ANV048*0**B*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION Extreme 24 HPwith ducted air handler FE4BNBD60L*+UICarrier4 tons46,000 Btu/h · Ducted2.4878%9.522.013.035,400CEE 25CEE 26XcelES CC217213361592
1241284ANV060*0**B*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION Extreme 24 HPwith ducted air handler FE4BNBD60L*+UICarrier5 tons58,000 Btu/h · Ducted2.2063%8.520.513.038,000CEE 25CEE 2694213361594
1242288BNV013*0**A*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION V Heat Pumpwith indoor coil CAP**2517AL*+UI and furnace 986TD30040C14Carrier1 ton13,000 Btu/h · Ducted2.0075%8.115.512.08,800Xcel9213892585
1243288BNV024B0**A*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**3721AL*+UI and furnace 88*TA48090C17Carrier2 tons24,400 Btu/h · Ducted2.0057%8.117.010.512,400None393204291591
1244288BNV024B0**A*+TSTATBRYANT HEATING AND COOLING SYSTEMSwith indoor coil H,PG31930 and furnace 926TC66100V21Carrier2 tons23,000 Btu/h · Ducted1.5030%7.516.09.59,200None50215289382
1245288BNV025*0**B*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**2517AL*+UI and furnace 88*TA48090C17Carrier2 tons24,400 Btu/h · Ducted2.0478%8.517.511.516,600CEE 25CEE 26Xcel485204456499
1246288BNV025*0**B*+TSTATBRYANT HEATING AND COOLING SYSTEMSwith ducted air handler FV4CN(B,F)005LCarrier2 tons24,600 Btu/h · Ducted2.0052%7.815.511.716,100None25204456301
1247288BNV025*0**C*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**2517AL*+UI and furnace 88*TA48090C17Carrier2 tons24,400 Btu/h · Ducted2.0478%8.517.511.516,600CEE 25CEE 26Xcel772206765555
1248288BNV025*0**C*+TSTATBRYANT HEATING AND COOLING SYSTEMSwith ducted air handler FV4CN(B,F)005LCarrier2 tons24,600 Btu/h · Ducted2.0052%7.815.511.716,100None158206765350
1249288BNV036*0**C*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**4321AL*+UI and furnace 88*TA48090C17Carrier3 tons34,000 Btu/h · Ducted1.9858%8.116.59.519,100None437206768521
1250288BNV037*0**A*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**6124AL*+UI and furnace 88*TA66135C24Carrier3 tons33,200 Btu/h · Ducted2.0278%8.518.012.024,800CEE 25CEE 26Xcel588210596553

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,695 models; narrow the filters for the rest.