9,824 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1526DLCURAH60ABKARCOAIRE · Dlserieswith ducted air handler DLFUAAH60XAK | Carrier | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | 8.8 | 48,500 | ES CC | 73 | 210025741 |
| 1527DLCVRAH09AAJARCOAIREwith ductless indoor unit DLFVHAH09XAJ | Carrier | 1 ton9,000 Btu/h · Non-ducted | 1.88 | 65% | 9.0 | 17.0 | 10.1 | 6,400 | CEE 25CEE 26 | 9 | 205967966 |
| 1528DLCVRAH09AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFVHAH09XAK | Carrier | 1 ton9,000 Btu/h · Non-ducted | 2.10 | 71% | 8.8 | 18.5 | 10.5 | 7,100 | CEE 25CEE 26XcelES CC | 18 | 205967968 |
| 1529DLCVRAH12AAJARCOAIREwith ductless indoor unit DLFVHAH12XAJ | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.04 | 54% | 8.7 | 17.4 | 8.8 | 6,500 | None | 9 | 205967967 |
| 1530DLCVRAH12AAKARCOAIREwith ductless indoor unit DLFVHAH12XAK | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 59% | 8.8 | 17.6 | 8.8 | 7,100 | None | 9 | 205967969 |
| 1531DLCVRAH18AAKARCOAIREwith ductless indoor unit DLFVHAH18XAK | Carrier | 1.5 tons17,000 Btu/h · Non-ducted | 1.84 | 56% | 8.7 | 18.3 | 9.9 | 10,100 | None | 9 | 205967970 |
| 1532DLCVRAH24AAKARCOAIREwith ductless indoor unit DLFVHAH24XAK | Carrier | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 63% | 8.0 | 16.7 | 8.9 | 15,100 | None | 9 | 205967971 |
| 1533GH5SAN418**AA*CARRIERwith ducted air handler L(E,G)M24F4 | Carrier | 1.5 tons17,200 Btu/h · Ducted | 2.51 | 50% | 7.9 | 14.6 | 12.3 | 8,900 | None | 1,510 | 213195121 |
| 1534GH5SAN424**AA*CARRIERwith ducted air handler L(E,G)M24F4 | Carrier | 2 tons22,600 Btu/h · Ducted | 2.62 | 54% | 7.9 | 15.3 | 12.5 | 13,000 | None | 1,873 | 213195263 |
| 1535GH5SAN430**AA*CARRIERwith ducted air handler L(E,F)W36A4 | Carrier | 2 tons25,800 Btu/h · Ducted | 2.65 | 55% | 7.5 | 14.6 | 12.0 | 15,500 | None | 1,390 | 213361312 |
| 1536GH5SAN436**AA*CARRIERwith ducted air handler PE(S,T)354 | Carrier | 3 tons33,000 Btu/h · Ducted | 2.45 | 56% | 7.5 | 14.5 | 11.7 | 18,500 | None | 2,283 | 215821256 |
| 1537GH5SAN442**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM59A44+TDR | Carrier | 3.5 tons39,000 Btu/h · Ducted | 2.69 | 58% | 7.7 | 14.6 | 12.1 | 24,600 | None | 2,108 | 213195014 |
| 1538GH5SAN448**AA*CARRIERwith ducted air handler AE(D,N,U)+DM59A44+TDR | Carrier | 3.5 tons43,500 Btu/h · Ducted | 2.64 | 59% | 7.5 | 14.4 | 11.9 | 27,400 | None | 334 | 212920364 |
| 1539GH5SAN460**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM59A44+TDR | Carrier | 4.5 tons53,000 Btu/h · Ducted | 2.72 | 60% | 7.5 | 14.3 | 11.7 | 34,000 | None | 223 | 213195015 |
| 1540GH7TAN424**AA*CARRIER · 2-STAGE 17 SEER HPwith indoor coil CAP**3721AL and furnace 59SU5B100M21**22 | Carrier | 2 tons23,600 Btu/h · Ducted | 2.40 | 45% | 8.1 | 17.0 | 12.5 | 11,000 | CEE 25 | 3,107 | 212321098 |
| 1541GH7TAN436**AA*CARRIER · 2-STAGE 17 SEER HPwith ducted air handler FT4BNBD60L | Carrier | 3 tons36,000 Btu/h · Ducted | 2.34 | 50% | 8.1 | 17.0 | 12.5 | 17,700 | CEE 25CEE 26 | 3,243 | 213925443 |
| 1542GH7TAN448**AA*CARRIER · 2-STAGE 17 SEER HPwith ducted air handler F54AA*C48L | Carrier | 4 tons46,500 Btu/h · Ducted | 2.34 | 51% | 8.1 | 16.0 | 12.5 | 24,000 | CEE 25CEE 26 | 2,335 | 213310402 |
| 1543GH7TAN460**AA*CARRIER · 2-STAGE 17 SEER HPwith ducted air handler F54AA*D60L | Carrier | 5 tons57,000 Btu/h · Ducted | 2.34 | 51% | 8.1 | 16.0 | 12.0 | 30,800 | CEE 25CEE 26 | 1,276 | 213310424 |
| 1544H4H5S18*K*AAA*AIRQUEST · MAINLINE 15 SEER2 HPwith indoor coil EA*4X19L17A and furnace *80ESU0401712A | Carrier | 1.5 tons18,300 Btu/h · Ducted | 2.02 | 47% | 7.5 | 15.2 | 12.5 | 7,900 | None | 1,222 | 210299971 |
| 1545H4H5S24*K*AAA*AIRQUEST · MAINLINE 15 SEER2 HPwith ducted air handler FMA4X30**AL | Carrier | 2 tons25,000 Btu/h · Ducted | 2.24 | 48% | 8.1 | 15.2 | 12.5 | 11,400 | None | 863 | 210099354 |
| 1546H4H5S30*K*AAA*AIRQUEST · MAINLINE 15 SEER2 HPwith ducted air handler FM(C,U)4Z30**AL | Carrier | 2.5 tons27,600 Btu/h · Ducted | 2.20 | 47% | 7.8 | 15.2 | 12.5 | 13,000 | None | 1,105 | 209692025 |
| 1547H4H5S36*K*AAA*AIRQUEST · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*48L*C | Carrier | 3 tons36,400 Btu/h · Ducted | 2.16 | 47% | 7.5 | 14.3 | 12.0 | 16,600 | None | 1,993 | 211231002 |
| 1548H4H5S42*K*AAA*HEIL · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*D | Carrier | 3.5 tons42,500 Btu/h · Ducted | 2.36 | 50% | 7.8 | 15.2 | 11.7 | 21,400 | None | 1,174 | 211581434 |
| 1549H4H5S48*K*AAA*HEIL · MAINLINE 15 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCON | Carrier | 4 tons47,000 Btu/h · Ducted | 2.26 | 47% | 7.5 | 15.2 | 12.0 | 22,000 | None | 126 | 213301773 |
| 1550H4H5S60*K*AAA*HEIL · MAINLINE 15 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCON | Carrier | 5 tons57,500 Btu/h · Ducted | 2.34 | 50% | 8.1 | 15.0 | 12.5 | 28,200 | None | 79 | 213301781 |