- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
9,824 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2251CH-36MES-230VOC&H · CH series | Cooper&Hunter | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 68% | 9.5 | 23.9 | 11.7 | 25,200 | CEE 25CEE 26 | 6 | 207742367 |
| 2252CH-36SPH-230VOC&Hwith ductless indoor unit CH-36SPH-230VI | Cooper&Hunter | 3 tons36,000 Btu/h · Non-ducted | — | — | 7.5 | 16.0 | 8.5 | — | None | 8 | 201755340 |
| 2253CH-48LCDTU/OC&Hwith ducted air handler CH-48LCDTU/I | Cooper&Hunter | 4 tons48,000 Btu/h · Ducted | — | — | 9.3 | 15.1 | 8.5 | — | None | 2 | 10443492 |
| 2254CH-48LCU/OC&Hwith ducted air handler CH-48LCDTU/I | Cooper&Hunter | 4 tons48,000 Btu/h · Ducted and non-ducted | — | — | 9.3 | 15.1 | 8.5 | — | None | 10 | 201755337 |
| 2255CH-48MES-230VOC&H · CH series | Cooper&Hunter | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 69% | 8.7 | 23.4 | 12.5 | 33,000 | CEE 25CEE 26 | 6 | 207742370 |
| 2256CH-55MES-230VOC&H | Cooper&Hunter | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 60% | 9.1 | 21.3 | 10.5 | 33,200 | CEE 25 | 6 | 208497425 |
| 2257CH-60LCDTU/OC&Hwith ducted air handler CH-60LCDTU/I | Cooper&Hunter | 5 tons57,000 Btu/h · Ducted | 2.08 | 59% | 8.4 | 15.4 | 9.0 | 35,600 | None | 2 | 10507898 |
| 2258CH-60LCU/OC&Hwith ducted air handler CH-60LCDTU/I | Cooper&Hunter | 5 tons57,000 Btu/h · Ducted and non-ducted | 2.08 | 59% | 8.4 | 15.4 | 9.0 | 35,600 | None | 7 | 201755338 |
| 2259CH-EL30-230VOC&H · CH serieswith ductless indoor unit CH-30ASTWM-230VI | Cooper&Hunter | 2.5 tons30,000 Btu/h · Non-ducted | 1.95 | 58% | 9.2 | 20.0 | 11.5 | 17,500 | CEE 25CEE 26 | 10 | 207740505 |
| 2260CH-EL36-230VOC&Hwith ductless indoor unit CH-36ELVWM-230VI | Cooper&Hunter | 3 tons36,000 Btu/h · Non-ducted | 2.01 | 61% | 7.8 | 18.0 | 9.5 | 22,000 | None | 8 | 207740517 |
| 2261CH-ES06-115VOC&H · CH serieswith ductless indoor unit CH-06OLVWM-115VI | Cooper&Hunter | 0.5 tons6,000 Btu/h · Non-ducted | 2.07 | 98% | 9.8 | 23.0 | 13.8 | 6,858 | CEE 25CEE 26Xcel | 2 | 210665996 |
| 2262CH-ES09-115VOC&H · CH serieswith ductless indoor unit CH-09OLVWM-115VI | Cooper&Hunter | 1 ton9,000 Btu/h · Non-ducted | 2.07 | 69% | 9.8 | 23.0 | 13.8 | 6,858 | CEE 25CEE 26 | 4 | 207765977 |
| 2263CH-ES09-230VOCooper&Hunter · CH serieswith ductless indoor unit CH-09MCT1W-230VI | Cooper&Hunter | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.37 | 77% | 11.5 | 22.5 | 13.0 | 8,500 | CEE 25CEE 26XcelES CC | 15 | 210857417 |
| 2264CH-ES12-115VOC&H · CH serieswith ductless indoor unit CH-12OLVWM-115VI | Cooper&Hunter | 1 ton12,000 Btu/h · Non-ducted | 2.07 | 56% | 10.4 | 22.7 | 12.5 | 6,700 | CEE 25CEE 26 | 4 | 207740531 |
| 2265CH-ES12-230VOC&H · CH serieswith ductless indoor unit CH-12MMC-230VI | Cooper&Hunter | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.45 | 72% | 11.0 | 25.0 | 13.0 | 8,600 | CEE 25CEE 26XcelES CC | 18 | 209937051 |
| 2266CH-ES18-230VOC&H · CH serieswith ducted air handler CH-M18DTUI | Cooper&Hunter | 1.5 tons17,000 Btu/h · Ducted and non-ducted | 2.40 | 65% | 10.6 | 20.0 | 12.5 | 13,000 | CEE 25CEE 26XcelES CC | 21 | 207742322 |
| 2267CH-ES24-230VOC&H · CH serieswith ducted air handler CH-M24DTUI | Cooper&Hunter | 2 tons23,000 Btu/h · Ducted and non-ducted | 2.30 | 80% | 11.2 | 19.0 | 12.5 | 20,000 | CEE 25CEE 26XcelES CC | 17 | 207742325 |
| 2268CH-HPR06F9-230VOC&H · CH serieswith ductless indoor unit CH-06MASTWM-230VI | Cooper&Hunter | 0.5 tons6,000 Btu/h · Non-ducted | 2.09 | 107% | 13.6 | 26.5 | 15.8 | 7,500 | CEE 25CEE 26XcelES CC | 8 | 207740500 |
| 2269CH-HPR09-230VOC&H · CH serieswith ductless indoor unit CH-09MASTWM-230VI | Cooper&Hunter | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.97 | 88% | 11.5 | 28.1 | 16.2 | 10,600 | CEE 25CEE 26XcelES CC | 17 | 207740501 |
| 2270CH-HPR12-230VOC&H · CH serieswith ductless indoor unit CH-12MMC-230VI | Cooper&Hunter | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 99% | 10.7 | 24.2 | 13.3 | 11,900 | CEE 25CEE 26XcelES CC | 21 | 209937052 |
| 2271CH-HPR18-230VOCooper&Hunter · CH serieswith ducted air handler CH-M18AHU | Cooper&Hunter | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.00 | 89% | 9.6 | 17.6 | 11.7 | 17,000 | CEE 25CEE 26XcelES CC | 24 | 208141205 |
| 2272CH-HPR19M-230VOC&H · CH series | Cooper&Hunter | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.83 | 100% | 9.8 | 22.0 | 12.5 | 20,000 | CEE 25CEE 26XcelES CC | 6 | 207742373 |
| 2273CH-HPR24-230VOC&H · CH serieswith ductless indoor unit CH-24MASTWM-230VI | Cooper&Hunter | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | 13.0 | 25,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 20 | 207740504 |
| 2274CH-HPR28M-230VOC&H · CH series | Cooper&Hunter | 2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 89% | 10.6 | 23.0 | 12.5 | 25,000 | CEE 25CEE 26XcelES CC | 6 | 207742376 |
| 2275CH-HPR35-230VOCooper&Hunter · CH serieswith ductless indoor unit CH-35HASTWM-230VI | Cooper&Hunter | 3 tons33,000 Btu/h · Non-ducted | 1.80 | 99% | 10.0 | 19.5 | 12.0 | 34,600 | CEE 25CEE 26XcelES CC | 1 | 212528018 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.