Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,696 models

Sorted by manufacturer and model.
Page 91 of 388
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2251CH-ES18-230VOC&H · CH serieswith ducted air handler CH-M18DTUICooper&Hunter1.5 tons17,000 Btu/h · Ducted and non-ducted2.4065%10.620.012.513,000CEE 25CEE 26XcelES CC21207742322
2252CH-ES24-230VOC&H · CH serieswith ducted air handler CH-M24DTUICooper&Hunter2 tons23,000 Btu/h · Ducted and non-ducted2.3080%11.219.012.520,000CEE 25CEE 26XcelES CC17207742325
2253CH-HPR06F9-230VOC&H · CH serieswith ductless indoor unit CH-06MASTWM-230VICooper&Hunter0.5 tons6,000 Btu/h · Non-ducted2.09107%13.626.515.87,500CEE 25CEE 26XcelES CC8207740500
2254CH-HPR09-230VOC&H · CH serieswith ductless indoor unit CH-09MASTWM-230VICooper&Hunter1 ton9,000 Btu/h · Ducted and non-ducted1.9788%11.528.116.210,600CEE 25CEE 26XcelES CC17207740501
2255CH-HPR12-230VOC&H · CH serieswith ductless indoor unit CH-12MMC-230VICooper&Hunter1 ton12,000 Btu/h · Ducted and non-ducted1.9999%10.724.213.311,900CEE 25CEE 26XcelES CC21209937052
2256CH-HPR18-230VOCooper&Hunter · CH serieswith ducted air handler CH-M18AHUCooper&Hunter1.5 tons18,000 Btu/h · Ducted and non-ducted2.0089%9.617.611.717,000CEE 25CEE 26XcelES CC24208141205
2257CH-HPR19M-230VOC&H · CH seriesCooper&Hunter1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.822.012.520,000CEE 25CEE 26XcelES CC6207742373
2258CH-HPR24-230VOC&H · CH serieswith ductless indoor unit CH-24MASTWM-230VICooper&Hunter2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.513.025,000CEE 25CEE 26CEE AdvXcelDOEES CC20207740504
2259CH-HPR28M-230VOC&H · CH seriesCooper&Hunter2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%10.623.012.525,000CEE 25CEE 26XcelES CC6207742376
2260CH-HPR35-230VOCooper&Hunter · CH serieswith ductless indoor unit CH-35HASTWM-230VICooper&Hunter3 tons33,000 Btu/h · Non-ducted1.8099%10.019.512.034,600CEE 25CEE 26XcelES CC1212528018
2261CH-HPR36M-230VOC&H · CH seriesCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%10.322.213.636,000CEE 25CEE 26XcelES CC6207742379
2262CH-HPR48M-230VOC&H · CH seriesCooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%9.821.811.745,000CEE 25CEE 26XcelES CC6207742381
2263CH-HPR55M-230VOC&H · CH seriesCooper&Hunter4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.522.010.547,000CEE 25CEE 26XcelES CC6208497428
2264CH-HYP36LCUOC&H · CH serieswith ducted air handler CH-36LCDTU/ICooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted1.9886%11.016.59.036,000ES CC3205901586
2265CH-HYP48LCUOC&H · CH serieswith ducted air handler CH-48LCDTU/ICooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted2.0288%10.314.38.246,000None10205263864
2266CH-N36LCU-230VOCooper&Hunterwith ducted air handler CH-36AHUCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted2.0663%9.015.48.224,000None11208101230
2267CH-N48LCU-230VOC&H · CH serieswith ductless indoor unit CH-N48LCCT-230VICooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted1.9869%9.818.59.534,600XcelES CC11207742341
2268CH-N60LCU-230VOC&Hwith ductless indoor unit CH-60LCFC/ICooper&Hunter4.5 tons54,000 Btu/h · Ducted and non-ducted2.0257%9.019.89.834,400None8207742345
2269CH-NH36LCUOC&Hwith ducted air handler CH-36AHUCooper&Hunter3 tons36,000 Btu/h · Ducted1.7042%7.514.88.023,000None2206597267
2270CH-NHPR36LCU-230VOC&H · CH serieswith ducted air handler CH-36LCDTU/ICooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted1.9886%11.016.59.036,000XcelES CC11207742347
2271CH-NHPR48LCU-230VOC&H · CH serieswith ducted air handler CH-48LCDTU/ICooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted2.0288%10.314.38.246,000ES CC11207742350
2272CH-NHPR60LCU-230VOCooper&Hunter · CH serieswith ductless indoor unit CH-60LCFC/ICooper&Hunter4.5 tons55,000 Btu/h · Ducted and non-ducted1.9794%10.217.39.056,500XcelES CC6211246027
2273CH-NY06MIA-115VOC&H · CH serieswith ductless indoor unit CH-NY06MIA-115VICooper&Hunter0.5 tons6,000 Btu/h · Non-ducted1.9294%9.021.512.56,601CEE 25CEE 26Xcel3210434545
2274CH-NY09MIA-115VOC&H · CH serieswith ductless indoor unit CH-09OLV-115VICooper&Hunter1 ton9,000 Btu/h · Non-ducted2.1670%9.121.512.57,000CEE 25CEE 26XcelES CC5207740507
2275CH-NY09MIA-230VOC&H · CH serieswith ductless indoor unit CH-09MOLV-230VICooper&Hunter1 ton9,000 Btu/h · Non-ducted1.9970%9.421.712.67,000CEE 25CEE 26XcelES CC5207740532

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,696 models; narrow the filters for the rest.