2,136 models

Sorted by manufacturer and model.
Page 1 of 86
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1ACIQ-48-EHPB1HVACwith ducted air handler ACIQ-48-AHB1HVAC4 tons47,000 Btu/h · Ducted1.9565%9.415.88.836,000None2213433222
2ACIQ-48-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-48-AHB1HVAC4 tons47,000 Btu/h · Ducted1.9092%9.415.68.246,000ES CC2208106640
3ACIQ-48Z-HH-M5B1HVAC · ACIQ1HVAC4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%9.821.811.745,000CEE 25CEE 26XcelES CC3207825573
4ACIQ-48ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-48CD-HH-MB1HVAC4 tons48,000 Btu/h · Ducted and non-ducted2.0288%10.314.38.246,000ES CC3210857302
5ACIQ-55Z-HH-M5B1HVAC · ACIQ1HVAC4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.522.010.547,000CEE 25CEE 26XcelES CC3210857362
6ACIQ-60-EHPB1HVACwith ducted air handler ACIQ-60-ACL1HVAC4.5 tons53,000 Btu/h · Ducted1.9059%8.515.29.032,000None2212394310
7ACIQ-60HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-60AHB1HVAC4.5 tons55,000 Btu/h · Ducted1.9182%9.415.38.848,500ES CC2210857353
8ACIQ-60ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-60CD-HH-MB1HVAC4.5 tons55,000 Btu/h · Ducted and non-ducted1.9793%9.515.89.453,000XcelES CC2210857303
9ACIQ-PHH1748000K000V1HVAC · Extreme Heat Inverter Rooftop1HVAC4 tons47,000 Btu/h · Ducted1.8098%8.517.811.046,000CEE 25CEE 26XcelES CC1215387220
10ACIQ-PHH1760000K000V1HVAC · Extreme Heat Inverter Rooftop1HVAC4.5 tons56,000 Btu/h · Ducted1.8079%8.317.010.645,000XcelES CC1215387221
11ES-48Z-M5B1HVAC · ES SERIES1HVAC4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%8.723.412.533,000CEE 25CEE 263210857374
12ES-55Z-M5B1HVAC1HVAC4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8060%9.121.310.533,200CEE 253210857377
13EZ-48-HP1HVAC · EZ Serieswith ducted air handler EZ-48-AH1HVAC4 tons47,000 Btu/h · Ducted1.8594%9.415.68.247,075ES CC1214810547
14EZ-48Z-M51HVAC · ES SERIES1HVAC4 tons48,000 Btu/h · Non-ducted1.8062%9.220.511.029,800CEE 25CEE 261214810567
15EZ-60-HP1HVAC · EZ Serieswith ducted air handler EZ-60-AH1HVAC4.5 tons55,000 Btu/h · Ducted1.9192%9.415.38.854,356ES CC1214810548
16HVH848GKA**1HVACwith indoor coil EHD4X48AAL+WALLCON and furnace *80CSU0802120A1HVAC4 tons45,500 Btu/h · Ducted2.3271%8.517.010.033,200CEE 25CEE 26Xcel52210599650
17HVH848GKA2*1HVACwith indoor coil EHD4X48AAL+WALLCON and furnace *95CSU1002122A1HVAC4 tons45,500 Btu/h · Ducted2.3071%8.516.59.533,200None1210470025
18HVH860GKA2*1HVACwith indoor coil EA*4X61L21A*+WALLCON and furnace *95CSU1002122A1HVAC4.5 tons56,500 Btu/h · Ducted2.1266%8.016.59.040,000None58210469674
19SC-42-EHPB1HVACwith ducted air handler SC-42-AHB1HVAC3.5 tons40,000 Btu/h · Ducted1.7859%7.815.59.023,400None1214610241
20SC-42Z-HH-M51HVAC1HVAC3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8274%8.616.09.031,200Xcel3208674915
21SC-48-EHPB1HVACwith ducted air handler SC-48-AHB1HVAC4 tons46,000 Btu/h · Ducted1.7657%7.715.08.626,200None1214610242
22SC-4860-HP1HVAC · Ultra Heat Unitary Condensing Unitwith ducted air handler SC-48-AH1HVAC4 tons48,000 Btu/h · Ducted1.8081%9.017.011.039,000CEE 25CEE 26XcelES CC2211717283
23SC-60-EHPB1HVACwith ducted air handler SC-60-AHB1HVAC4.5 tons54,000 Btu/h · Ducted1.7758%7.815.210.031,400None1214610243
24NDGR049*15 SERIES GEO-READY · 5 SERIES GEO-READYwith ducted air handler NGV/NGH049*1*(1,2)5 SERIES GEO-READY4 tons47,000 Btu/h · Ducted2.8549%8.615.512.323,300None1208101993
25GPHH34241A*ABCOOLAIRABCOOLAIR3.5 tons39,000 Btu/h · Ducted1.6141%6.713.410.615,200None1211899436

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,136 models; narrow the filters for the rest.