Skip to content

Ranked by Capacity retention at 5°F only, for their size and type

Heating capacity at 5°F as a percentage of rated heating capacity at 47°F. This board ranks by that one rating; it is not the overall cold-climate verdict, which is the cold-climate board. Small units rate higher than large ones and ductless units higher than ducted ones, so this board does not rank raw numbers across sizes. Each model is ranked by the share of comparable models (same size and duct type) it beats, one model per manufacturer. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

New to heat pump ratings? The Simple view explains them in plain words →

LeaderboardsData as of updated · sources

Top 25 ranked by Capacity retention at 5°F only, against their peers

Where each leader sits in its own peer groupCapacity retention at 5°F of every model, one row per size and duct type · dots are the leaderboard below · R-410AEach row is one size and duct type. Leaders are ranked by how far they stand out in their own row, not by the raw number. The #1, Fujitsu AOU9RLFF, beats 100% of 2,419 non-ducted, up to 1.5 tons models.
  • All models of the group (shape)
  • Leaderboard model
  • Median and middle 50% / 80%
  • Standard threshold
Ducted, up to 1.5 tons74%884 modelsDucted, 2 tons75%822 modelsDucted, 2.5–3 tons65%1,613 modelsDucted, 3.5–4.5 tons65%1,482 modelsDucted, 5 tons and up54%239 modelsNon-ducted, up to 1.5 tons71%2,419 modelsNon-ducted, 2 tons75%611 modelsNon-ducted, 2.5–3 tons69%975 modelsNon-ducted, 3.5–4.5 tons71%438 modelsNon-ducted, 5 tons and up70%32 modelsmedian

Rows: every model through its representative certification, each shape scaled to its own peak (the model count is printed). Dots: each leader's best certification on this rating, the one it is ranked by; an arrowhead marks a value beyond the axis.
Show the data as a table
Capacity retention at 5°F by peer group (every model's representative certification)
Peer groupModels10th pct.25thMedian75th90th
Ducted, up to 1.5 tons88452%64%74%95%100%
Ducted, 2 tons82245%53%75%92%105%
Ducted, 2.5–3 tons1,61342%55%65%82%90%
Ducted, 3.5–4.5 tons1,48239%51%65%81%88%
Ducted, 5 tons and up23939%42%54%59%70%
Non-ducted, up to 1.5 tons2,41956%66%71%88%100%
Non-ducted, 2 tons61161%63%75%89%100%
Non-ducted, 2.5–3 tons97558%61%69%89%100%
Non-ducted, 3.5–4.5 tons43860%69%71%91%92%
Non-ducted, 5 tons and up3250%58%70%72%78%

Source: AHRI Directory · as of

Ranked by the share of comparable models (same size and duct type) each model beats on Capacity retention at 5°F, using each model’s best certification; equal shares go to the model further above its group’s typical value. The raw Capacity retention at 5°F is shown but not compared across sizes.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.Compared withBeats
1AOU9RLFFFUJITSU · H-Serieswith ductless indoor unit AGU9RLFFujitsu1 ton9,000 Btu/h · Non-ducted158%1.9811.826.016.014,220CEE 25CEE 26XcelES CC16936995Non-ducted, up to 1.5 tons2,419 models100%
2WDLCURAH18ABKGRANDAIREwith indoor coil WLNC304BA and furnace WFAX080B048BCarrier1.5 tons17,400 Btu/h · Ducted160%1.968.116.511.028,600CEE 25CEE 26CEE AdvXcelDOEES CC286212984768Ducted, up to 1.5 tons921 models100%
3ROSH09AFFHJRUUDwith ductless indoor unit RIFH09AVFJRheem1 ton9,000 Btu/h · Non-ducted149%1.9011.626.016.013,400CEE 25CEE 26Xcel2206221508Non-ducted, up to 1.5 tons2,419 models100%
4THE2B18S21COLEMANwith ducted air handler 96-853+TXV+TDR+E30B3DYork1.5 tons16,200 Btu/h · Ducted149%1.807.514.312.022,000None585210857054Ducted, up to 1.5 tons921 models100%
5AC018BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC018BN4DCHSamsung1.5 tons18,000 Btu/h · Non-ducted146%1.928.523.613.826,200CEE 25CEE 26Xcel9207462388Non-ducted, up to 1.5 tons2,419 models100%
64HP17L18P-**ACONCORDwith ducted air handler C/SEHX-18-**-ED-1C80+CF018SCF2B+TXV+TDRLennox1.5 tons17,000 Btu/h · Ducted147%1.808.116.013.022,000CEE 25CEE 26Xcel2,076214320262Ducted, up to 1.5 tons921 models100%
7BOVD-36HDN1-M20GBOSCHwith indoor coil D(A,C,E)36A34+TDR and furnace BGH96M100C5BBosch2.5 tons29,800 Btu/h · Ducted126%3.038.718.011.032,000CEE 25CEE 26CEE AdvXcelDOE113215375432Ducted, 2.5–3 tons1,610 models100%
84A6H4042N1AMERICAN STANDARDwith indoor coil H,TG74960 and furnace S8V2C080M5PCATrane3.5 tons40,000 Btu/h · Ducted120%—7.514.512.045,000None2,081214609640Ducted, 3.5–4.5 tons1,507 models100%
9ARUM036GSS5LG · ARUM036GSS5LG3 tons36,000 Btu/h · Non-ducted114%1.8310.623.015.548,000CEE 25CEE 26XcelES CC3205967237Non-ducted, 2.5–3 tons975 models100%
10FRP18AZ48AJVCFRIEDRICHwith indoor coil TCFZ4821SEAAM and furnace FR951V0705A21UHUFriedrich3.5 tons44,500 Btu/h · Ducted105%1.808.119.010.042,000CEE 25CEE 26XcelES CC21214802163Ducted, 3.5–4.5 tons1,507 models100%
11GWH09ACD-D3DNA1A/OGREE · Fairywith ductless indoor unit GWH09ACD-D3DN***/IAlso sold as Tosot TW09HQ3D6DO, Ac Pro.Com AWH09ACD-D3DNA1A/O, Kinghome KW09HQ3D6DOGree1 ton9,000 Btu/h · Non-ducted144%1.9111.027.016.613,000CEE 25CEE 26XcelES CC510318077Non-ducted, up to 1.5 tons2,419 models99%
12BMKH0938/OBLUERIDGE · Saphirewith ductless indoor unit BMKH0938/IBlueRidge1 ton9,000 Btu/h · Non-ducted144%1.9111.027.016.613,000CEE 25CEE 26XcelES CC1205968027Non-ducted, up to 1.5 tons2,419 models99%
13EIN10H2V32(O)INNOVAIR · Innovair Elitewith ductless indoor unit EIN10H2V32(I)Innovair1 ton9,000 Btu/h · Non-ducted144%1.9111.027.016.613,000CEE 25CEE 26XcelES CC1206330207Non-ducted, up to 1.5 tons2,419 models99%
14GSZB401810A*GOODMANwith ducted air handler C/SEHX-19-**-ED-1C80+CF019SCWB+TXV+TDRDaikin1.5 tons16,400 Btu/h · Ducted141%1.807.514.312.022,000None480214731880Ducted, up to 1.5 tons921 models99%
15MOX330-09HFN1-MY6WMDV · MFA serieswith ductless indoor unit MFA2U-09HRFN1-MY6WMidea1 ton9,000 Btu/h · Non-ducted137%2.1011.426.315.712,300CEE 25CEE 26CEE AdvXcelDOEES CC1209248923Non-ducted, up to 1.5 tons2,419 models99%
16MXZ-SM60NAM***Mitsubishi Electric · Smart MultiMitsubishi Electric5 tons60,000 Btu/h · Ducted88%1.808.615.510.457,000Xcel3213248843Ducted, 5 tons and up200 models100%
17AMW4-36U3STAHISENSE · Hi MULTI Xtremewith ductless indoor unit AST-09UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**00Hisense2.5 tons32,000 Btu/h · Non-ducted113%1.849.021.012.536,000CEE 25CEE 26XcelES CC4202911535Non-ducted, 2.5–3 tons975 models99%
18WHP36M4A21SWESTINGHOUSE · Hi MULTI XtremeNortek Global HVAC2.5 tons32,000 Btu/h · Non-ducted113%1.849.021.012.536,000CEE 25CEE 26XcelES CC3205446269Non-ducted, 2.5–3 tons975 models99%
19EODA19H-4860AA*ECOERwith ducted air handler D(A,C,E)60B44+TDREcoer4 tons50,000 Btu/h · Ducted100%1.908.515.210.742,000CEE 25CEE 26XcelES CC37217361951Ducted, 3.5–4.5 tons1,507 models98%
20SENA-36HF-MOBSENVILLE · SENA SeriesSenville3 tons36,000 Btu/h · Non-ducted103%2.0010.922.412.537,000CEE 25CEE 26XcelES CC3213732656Non-ducted, 2.5–3 tons975 models97%
21MDPH180484MRCOOL · Universal Series Inverter Packaged Heat PumpMRCOOL4 tons47,000 Btu/h · Ducted98%1.808.517.811.046,000CEE 25CEE 26XcelES CC1214097892Ducted, 3.5–4.5 tons1,507 models97%
22CH-NHPR48LCU-230VOCooper&Hunter · CH serieswith ducted air handler CH-48AHUCooper&Hunter4 tons47,000 Btu/h · Ducted97%1.808.814.67.846,443None11208141208Ducted, 3.5–4.5 tons1,507 models97%
23BZ33-HYP48OUT2-G2-PBreeze33 · BZ33 serieswith ducted air handler BZ33-MSAHU48-G2-PBreeze334 tons47,000 Btu/h · Ducted97%1.808.814.67.846,443None4211273238Ducted, 3.5–4.5 tons1,507 models97%
24DRA1U09S1BDurastar · DRA1with ductless indoor unit DRAL06F1ADurastar0.5 tons6,500 Btu/h · Non-ducted113%2.0010.822.014.58,000CEE 25CEE 26XcelES CC6210568102Non-ducted, up to 1.5 tons2,419 models95%
25ASH109URDE**GE Appliances · Endurewith ductless indoor unit ASYW09URDEGE Appliances1 ton9,000 Btu/h · Non-ducted106%1.8914.030.016.010,600CEE 25CEE 26XcelES CC4212409456Non-ducted, up to 1.5 tons2,419 models92%

Download CSV of the Capacity retention at 5°F leaderboardThis leaderboard with each model’s peer percentile.

How peer groups and percentiles work

Typical capacity retention at 5°F by size and duct type

The median model of each peer group. The spread between groups is why models are only compared within their own.
Median Capacity retention at 5°F of the representative certification, per peer group
Peer groupModelsMedian Cap. 5/47
Ducted, up to 1.5 tons95874%
Ducted, 2 tons95875%
Ducted, 2.5–3 tons2,03365%
Ducted, 3.5–4.5 tons2,07465%
Ducted, 5 tons and up36154%
Non-ducted, up to 1.5 tons2,70471%
Non-ducted, 2 tons69975%
Non-ducted, 2.5–3 tons1,17769%
Non-ducted, 3.5–4.5 tons47971%
Non-ducted, 5 tons and up3270%