Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F. COP at 5°F alone is not used: it is measured at whatever heat output the unit delivers at 5°F, so a unit with little output there can still post a high COP. The single-rating boards remain, each labelled as ranked by that one rating. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

New to heat pump ratings? The Simple view explains them in plain words →

LeaderboardsData as of updated · sources

Top cold-climate picks: Ducted, 5 tons and up

24 of 360 models in this size class qualify. 212 keep less than 70% of their heat at 5°F and 122 have no 5°F heat output rating, so they cannot show it. 19 of the qualifiers are from manufacturers with a QMID on file (the ranked pool).

Ducted, 5 tons and up: qualifiers ranked by cold-climate score (mean of the three peer percentiles); equal scores go to the higher heat output at 5°F. Every number in a row is from the pairing the score is computed on: in each duct type, the model’s best-scoring pairing that keeps at least 70% of its heat.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2EER2MeetsCombosAHRI ref.ScoreBeats on Cap. 5/47Beats on COP@5°FBeats on HSPF2
1MCY-MAP0607HS-UL*TOSHIBA CARRIER · MCY-MAP0607HS-UL*Carrier5 tons60,000 Btu/h · Ducted78%2.209.846,50018.410.3CEE 25CEE 26Xcel321335025191.597%77%100%
2LMU601HVLG · LMU601HVLG5 tons60,000 Btu/h · Ducted70%1.979.545,00018.511.0CEE 25CEE 26XcelES CC320671700381.795%51%99%
3AM060MXMDCHSAMSUNG · DVM S EcoAlso listed as AM060NXMDCRSamsung5 tons60,000 Btu/h · Ducted78%1.869.547,00016.59.9CEE 25CEE 2631014709675.798%30%99%
4ARUN060GSS4LG · ARUN060GSS4LG5 tons60,000 Btu/h · Ducted78%1.839.150,00016.210.0CEE 25CEE 26XcelES CC31051471175.098%29%99%
5MXZ-SM60NAM***Mitsubishi Electric · Smart MultiMitsubishi Electric5 tons60,000 Btu/h · Ducted88%1.808.657,00015.510.4Xcel321324884372.8100%26%93%
6MXZ-SM60NAM2Mitsubishi Electric · Smart MultiAlso sold as Trane / Mitsubishi Electric NTXMSM60A182BMitsubishi Electric5 tons60,000 Btu/h · Ducted70%1.809.046,50017.010.6CEE 25CEE 26XcelES CC321101646272.696%26%96%
7MXZ-SM60NAM2***Mitsubishi Electric · Smart MultiAlso sold as Trane / Mitsubishi Electric NTXMSM60A182BMitsubishi Electric5 tons60,000 Btu/h · Ducted72%1.808.646,50015.510.4XcelES CC321324894171.796%26%93%
8MRB-60HWD1N1-M19MIDEA · MRDV-18HAlso listed as MRD-60HWD1N1-M18Midea5 tons57,000 Btu/h · Ducted70%1.759.040,00018.011.2CEE 25CEE 26Xcel120268057770.293%22%96%
9BRB-60HWD1N1-M19BOSCHAlso listed as BRBA-60HWD1N1-M18Bosch5 tons57,000 Btu/h · Ducted70%1.759.040,00018.011.2CEE 25CEE 26Xcel120268059070.293%22%96%
10YMKE60BNJMFMO-XYORKYork5 tons57,000 Btu/h · Ducted70%1.759.040,00018.011.2CEE 25CEE 26Xcel120573919670.293%22%96%

Ducted, 5 tons and up board

Top cold-climate picks: Non-ducted, 5 tons and up

17 of 32 models in this size class qualify. 13 keep less than 70% of their heat at 5°F. 16 of the qualifiers are from manufacturers with a QMID on file (the ranked pool).

Non-ducted, 5 tons and up: qualifiers ranked by cold-climate score (mean of the three peer percentiles); equal scores go to the higher heat output at 5°F. Every number in a row is from the pairing the score is computed on: in each duct type, the model’s best-scoring pairing that keeps at least 70% of its heat.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2EER2MeetsCombosAHRI ref.ScoreBeats on Cap. 5/47Beats on COP@5°FBeats on HSPF2
1MCY-MAP0607HS-UL*TOSHIBA CARRIER · MCY-MAP0607HS-UL*Carrier5 tons60,000 Btu/h · Non-ducted78%2.4010.646,50023.112.3CEE 25CEE 26Xcel321335025289.281%87%100%
2ARUB060GSS4LGLG5 tons60,000 Btu/h · Non-ducted88%2.459.656,53719.611.5CEE 25CEE 26XcelES CC31027165971.5100%90%24%
3MXZ-SM60NAM***Mitsubishi Electric · Smart MultiAlso sold as Trane / Mitsubishi Electric NTXMSM60A182AMitsubishi Electric5 tons60,000 Btu/h · Non-ducted72%2.0010.546,50020.013.3CEE 25CEE 26Xcel321324884460.276%26%79%
4LMU601HVLG · LMU601HVLG5 tons60,000 Btu/h · Non-ducted72%2.0110.046,00020.511.3CEE 25CEE 26XcelES CC320671701557.574%39%60%
5MXZ-SM60NAM2MITSUBISHI ELECTRIC · Smart MultiAlso sold as Trane / Mitsubishi Electric NTXMSM60A182B; also listed as PUMY-P60NKMU4, MXZ-SM60NAM2Mitsubishi Electric5 tons60,000 Btu/h · Non-ducted70%2.0010.546,50020.013.3CEE 25CEE 26XcelES CC321101646156.565%24%81%
6ARUN060GSS4LG · ARUN060GSS4LG5 tons60,000 Btu/h · Non-ducted78%1.8310.050,00023.010.0CEE 25CEE 26XcelES CC31051471048.984%3%60%
7AM060MXMDCHSAMSUNG · DVM S EcoAlso listed as AM060NXMDCRSamsung5 tons60,000 Btu/h · Non-ducted78%1.899.847,00019.011.2CEE 25CEE 26Xcel31014709746.289%8%42%
8GMV-V60WL/C-T(U)GREE · Ultra Heat GMV6 MiniAlso sold as Tosot TVRF-V60WL/C, Kinghome KUV-60UHOGree5 tons60,000 Btu/h · Non-ducted70%2.109.242,00021.011.0CEE 25CEE 26XcelES CC321169466036.050%50%8%

Non-ducted, 5 tons and up board

Download CSV of these cold-climate boardsEvery board above in one file, ranked by cold-climate score within each peer group.