Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025 Tier 1 (Split ASHP): 4,667 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 48.1%
- Qualifying models
- 4,667
- Qualifying certifications
- 98,141
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 123 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 115 |
| 1.70 to under 1.80 | 716 |
| 1.80 to under 1.90 | 2,089 |
| 1.90 to under 2.00 | 1,248 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 607 |
| 2.20 to under 2.30 | 477 |
| 2.30 to under 2.40 | 345 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 366 |
| 40 to under 45% | 200 |
| 45 to under 50% | 286 |
| 50 to under 55% | 599 |
| 55 to under 60% | 783 |
| 60 to under 65% | 886 |
| 65 to under 70% | 799 |
| 70 to under 75% | 1,049 |
| 75 to under 80% | 488 |
| 80 to under 85% | 537 |
| 85 to under 90% | 414 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 387 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 711 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 263 |
| 7.3 to under 7.5 | 67 |
| 7.5 to under 7.8 | 1,052 |
| 7.8 to under 8.0 | 534 |
| 8.0 to under 8.3 | 813 |
| 8.3 to under 8.5 | 123 |
| 8.5 to under 8.8 | 1,436 |
| 8.8 to under 9.0 | 268 |
| 9.0 to under 9.3 | 947 |
| 9.3 to under 9.5 | 363 |
| 9.5 to under 9.8 | 693 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 623 |
| 10.3 to under 10.5 | 171 |
| 10.5 to under 10.8 | 303 |
| 10.8 to under 11.0 | 79 |
| 11.0 to under 11.3 | 175 |
| 11.3 to under 11.5 | 85 |
| 11.5 to under 11.8 | 116 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 678 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 318 |
| 15.0 to under 15.5 | 1,004 |
| 15.5 to under 16.0 | 355 |
| 16.0 to under 16.5 | 714 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 371 |
| 18.5 to under 19.0 | 279 |
| 19.0 to under 19.5 | 593 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 388 |
| 10.0 to under 10.5 | 901 |
| 10.5 to under 11.0 | 1,175 |
| 11.0 to under 11.5 | 983 |
| 11.5 to under 12.0 | 1,096 |
| 12.0 to under 12.5 | 918 |
| 12.5 to under 13.0 | 1,266 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons69.5% · 2,175 of 3,130
- 2 tons56.5% · 813 of 1,440
- 2.5–3 tons41.3% · 1,075 of 2,606
- 3.5–4.5 tons25.3% · 547 of 2,162
- 5 tons and up15.9% · 57 of 358
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 69.5% · 2,175 of 3,130 |
| 2 tons | 56.5% · 813 of 1,440 |
| 2.5–3 tons | 41.3% · 1,075 of 2,606 |
| 3.5–4.5 tons | 25.3% · 547 of 2,162 |
| 5 tons and up | 15.9% · 57 of 358 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 25.6% | 1,176 / 4,598 |
| Non-ducted | 60.4% | 1,955 / 3,236 |
| Ducted and non-ducted | 82.5% | 1,536 / 1,862 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Mitsubishi Electric | 253 of 373 | 67.8% |
| Midea | 242 of 402 | 60.2% |
| Gree | 233 of 395 | 59% |
| Carrier | 200 of 701 | 28.5% |
| Lennox | 148 of 371 | 39.9% |
| Rheem | 117 of 291 | 40.2% |
| Hisense | 103 of 159 | 64.8% |
| Daikin | 99 of 367 | 27% |
| Trane | 97 of 309 | 31.4% |
| ACIQ | 66 of 161 | 41% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 2701ASZS601810A*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE24BP1400A | Liberty Heating & Air Conditioning | 1.5 tons16,600 Btu/h · Ducted | 2.10 | 75% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 130 | 211178339 |
| 2702ASZS602410A*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE24BP1400A | Liberty Heating & Air Conditioning | 2 tons22,200 Btu/h · Ducted | 1.99 | 60% | 8.5 | 17.3 | CEE 25 | 130 | 211178340 |
| 2703ASZS60241EA*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE36CP1400B | Liberty Heating & Air Conditioning | 2 tons23,000 Btu/h · Ducted | 2.00 | 70% | 8.6 | 17.0 | CEE 25CEE 26Xcel | 155 | 214389633 |
| 2704ASZS60361EA*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE48DP1400B | Liberty Heating & Air Conditioning | 3 tons34,200 Btu/h · Ducted | 2.00 | 88% | 8.6 | 17.5 | CEE 25CEE 26Xcel | 35 | 214389634 |
| 2705ASZS60421EA*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA6030*4A and furnace G*VC801005C*A | Liberty Heating & Air Conditioning | 3.5 tons40,000 Btu/h · Ducted | 2.20 | 77% | 8.6 | 17.0 | CEE 25CEE 26Xcel | 25 | 214389647 |
| 2706ASZS60481EA*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE60DP1400B | Liberty Heating & Air Conditioning | 3.5 tons44,000 Btu/h · Ducted | 2.00 | 70% | 8.6 | 17.0 | CEE 25CEE 26Xcel | 25 | 214389636 |
| 2707ASZV902410A*Liberty Heating & Air Conditioning · ASZV9with indoor coil CA*F3137*6A*+TXV and furnace G*VS800604BUA | Liberty Heating & Air Conditioning | 2 tons23,000 Btu/h · Ducted | 2.20 | 56% | 8.0 | 21.0 | CEE 25CEE 26 | 46 | 210693272 |
| 2708ASZV903610A*Liberty Heating & Air Conditioning · ASZV9with ducted air handler CA*F3743*6D*+MBVC1601**-1A*+TX | Liberty Heating & Air Conditioning | 3 tons34,200 Btu/h · Ducted | 1.85 | 71% | 8.2 | 19.0 | CEE 25CEE 26Xcel | 102 | 210607415 |
| 2709ASZV904810A*Liberty Heating & Air Conditioning · ASZV9with ducted air handler CA*F4961*6D*+MBVC2001**-1A*+TX | Liberty Heating & Air Conditioning | 4 tons45,000 Btu/h · Ducted | 1.82 | 57% | 8.2 | 19.0 | CEE 25CEE 26 | 64 | 210607420 |
| 2710GSZC702410A*Liberty Heating & Air Conditioning · GSZC7with ducted air handler AMVT30BP1400A | Liberty Heating & Air Conditioning | 2 tons23,800 Btu/h · Ducted | 2.00 | 47% | 8.2 | 17.2 | CEE 25 | 50 | 211946525 |
| 2711GSZC703610A*Liberty Heating & Air Conditioning · GSZC7with ducted air handler AMVT42CP1400A | Liberty Heating & Air Conditioning | 3 tons34,800 Btu/h · Ducted | 2.00 | 50% | 8.1 | 17.2 | CEE 25CEE 26 | 62 | 211946554 |
| 2712GSZC704810A*Liberty Heating & Air Conditioning · GSZC7with ducted air handler AMVT60DP1400A | Liberty Heating & Air Conditioning | 4 tons46,500 Btu/h · Ducted | 2.00 | 45% | 8.2 | 17.2 | CEE 25 | 46 | 211946591 |
| 2713LWSM-09IR410AHS22LLive cool · REXwith ductless indoor unit LWSM-09IR410AHS22L | Live cool | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 74% | 9.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218037237 |
| 2714LWSM-09IR410AHS23Live cool · REXwith ductless indoor unit LWSM-09IR410AHS23 | Live cool | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 77% | 9.2 | 23.5 | CEE 25CEE 26XcelES CC | 1 | 218037239 |
| 2715LWSM-12IR410AHS22LLive cool · REXwith ductless indoor unit LWSM-12IR410AHS22L | Live cool | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 73% | 9.0 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 218037238 |
| 2716LWSM-12IR410AHS23Live cool · REXwith ductless indoor unit LWSM-12IR410AHS23 | Live cool | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 76% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218037240 |
| 2717LWSM-18IR410AHS21.5Live cool · REXwith ductless indoor unit LWSM-18IR410AHS21.5 | Live cool | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 66% | 9.0 | 22.0 | CEE 25CEE 26 | 1 | 218037241 |
| 2718LWSM-24IR410AHS20Live cool · REXwith ductless indoor unit LWSM-24IR410AHS20 | Live cool | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 67% | 9.0 | 20.0 | CEE 25CEE 26 | 1 | 218037242 |
| 2719GSSHAX7488*LLOYDwith ductless indoor unit GSSHAX7487 | LLOYD | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 214731814 |
| 2720GSSHAX7490*LLOYDwith ductless indoor unit GSSHAX7489 | LLOYD | 1 ton12,000 Btu/h · Non-ducted | 1.75 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 214731815 |
| 2721GSSHAX7492*LLOYDwith ductless indoor unit GSSHAX7491 | LLOYD | 1 ton12,000 Btu/h · Non-ducted | 1.75 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 214731816 |
| 2722GSSHAX7496*LLOYDwith ductless indoor unit GSSHAX7495 | LLOYD | 2 tons24,000 Btu/h · Non-ducted | 1.78 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 214731818 |
| 2723DLCERBH09AAJLPS Legacy · DLC-serieswith ductless indoor unit DLFEHBH09XAJ | LPS Legacy | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.1 | 21.5 | CEE 25CEE 26XcelES CC | 1 | 211756585 |
| 2724DLCERBH09AAKLPS Legacy · DLC-serieswith ductless indoor unit DLFEHBH09XAK | LPS Legacy | 1 ton9,000 Btu/h · Non-ducted | 1.99 | 70% | 9.4 | 21.7 | CEE 25CEE 26XcelES CC | 1 | 211756601 |
| 2725DLCERBH12AAKLPS Legacywith ductless indoor unit DLFEHBH12XAK | LPS Legacy | 1 ton12,000 Btu/h · Non-ducted | 1.79 | 67% | 9.2 | 21.4 | CEE 25CEE 26 | 1 | 211756491 |