Skip to content

CEE 2025 Tier 1 (Split ASHP): 4,801 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
48.9%
Qualifying models
4,801
Qualifying certifications
98,649
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%92% of rated models reach 45% (the lowest path) on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons70.1% · 2,244 of 3,201
2 tons57.2% · 832 of 1,454
2.5 to 3 tons42.1% · 1,109 of 2,633
3.5 to 4.5 tons25.6% · 557 of 2,174
5 tons and up16.3% · 59 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted25.5%1,174 / 4,608
Non-ducted62.2%2,064 / 3,317
Ducted and non-ducted82.3%1,563 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric260 of 40065%
Midea246 of 40860.3%
Gree241 of 40359.8%
Carrier200 of 70128.5%
Lennox148 of 37539.5%
Hisense119 of 16074.4%
Rheem117 of 29140.2%
Daikin99 of 37126.7%
Trane97 of 30931.4%
ACIQ67 of 16141.6%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 161 of 193
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
4001RD17AZ24AJ3NRUSSELLwith ducted air handler TCFZ2417MTANM+RXMD-C03RUSSELL2 tons22,800 Btu/h · Ducted2.2467%7.514.3CEE 25CEE 26XcelES CC79214065130
4002RD17AZ36AJ3NRUSSELLwith ducted air handler RF2TZ3624STANSRUSSELL2.5 tons32,400 Btu/h · Ducted2.4058%8.117.0CEE 25CEE 26XcelES CC111214100072
4003RD17AZ48AJ3NRUSSELLwith indoor coil TCFZ6024STANM and furnace S802V1005A21UHSRUSSELL4 tons45,500 Btu/h · Ducted2.4056%8.116.0CEE 25CEE 26XcelES CC98214075619
4004SP15AZ24AJ2NRUSSELL · VANTIXwith indoor coil TCFZ2417STANM and furnace S801V1004A17UHSRUSSELL2 tons22,800 Btu/h · Ducted2.4057%8.116.0CEE 25CEE 26ES CC51212941614
4005SP15AZ30AJ2NRUSSELL · VANTIXwith ducted air handler SH2CZ3617STANNRUSSELL2.5 tons28,400 Btu/h · Ducted2.2055%7.815.2CEE 25CEE 26ES CC81211627534
4006SP15AZ60AJ2NRUSSELL · VANTIXwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHSRUSSELL5 tons57,000 Btu/h · Ducted2.6060%8.115.2CEE 25CEE 26ES CC36212387320
4007SP18AZ24AJVCRUSSELL · VANTIXwith indoor coil TCFZ2421HEAAM and furnace S802V0504A17UHSRUSSELL2 tons22,800 Btu/h · Ducted2.10108%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC27212609309
4008SP18AZ36AJVCRUSSELL · VANTIXwith ducted air handler SHMVZ6021SEACARUSSELL3 tons34,200 Btu/h · Ducted2.20121%8.518.0CEE 25CEE 26CEE AdvXcelDOEES CC30210106900
4009SP18AZ48AJVCRUSSELLwith indoor coil TCFZ6021SEAAM and furnace S962V0705A21M4SRUSSELL3.5 tons44,000 Btu/h · Ducted2.00103%8.118.0CEE 25CEE 26XcelES CC22210106962
4010SP18AZ60AJVCRUSSELLwith indoor coil TCFZ6021SEAAM and furnace S962V0705A21M4SRUSSELL4.5 tons52,500 Btu/h · Ducted2.0096%8.118.0CEE 25CEE 26Xcel15210106984
4011AC009BXADCHSAMSUNG · Mini 4-Way Cassette (WindFree™)with ductless indoor unit AC009BNNDCHSamsung1 ton9,100 Btu/h · Ducted and non-ducted1.89121%9.522.0CEE 25CEE 26Xcel5207462387
4012AC012BXADCHSAMSUNG · Slim Duct (LSP)with ducted air handler AC012BNLDCHSamsung1 ton12,000 Btu/h · Ducted and non-ducted1.9582%9.219.0CEE 25CEE 26Xcel5207465443
4013AC018BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC018BN4DCHSamsung1.5 tons18,000 Btu/h · Ducted and non-ducted1.92146%8.523.6CEE 25CEE 26Xcel9207462388
4014AC024BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC024BN4DCHSamsung2 tons24,000 Btu/h · Ducted and non-ducted1.83104%8.621.0CEE 25CEE 26Xcel5207462389
4015AC030BXADCHSAMSUNG · Duct S (HSP)with ducted air handler AC030BNHDCHSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted1.9397%8.418.2CEE 25CEE 26Xcel5207465458
4016AC030BXSCCHSAMSUNG · 4-Way Cassette (WindFree™) Max Heatwith ductless indoor unit AC030BN4DCHSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted2.03114%8.922.6CEE 25CEE 26Xcel3207698065
4017AC036BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC036BN4DCHSamsung3 tons36,000 Btu/h · Ducted and non-ducted2.17103%8.820.5CEE 25CEE 26CEE AdvXcelDOE5207462390
4018AC036BXSCCHSAMSUNG · 4-Way Cassette (WindFree™) Max Heatwith ductless indoor unit AC036BN4DCHSamsung3 tons36,000 Btu/h · Ducted and non-ducted2.12107%9.121.6CEE 25CEE 26CEE AdvXcelDOE3207698071
4019AC042BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC042BN4DCHSamsung3.5 tons42,000 Btu/h · Ducted and non-ducted1.98104%8.719.1CEE 25CEE 26Xcel4207462391
4020AJ020BXJ2CHSAMSUNG · FJMSamsung1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7670%8.619.5CEE 25CEE 26Xcel3207349914
4021AJ020BXS3CHSAMSUNG · FJM Max HeatSamsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95100%9.019.0CEE 25CEE 26Xcel3207349917
4022AJ020CXS3CHSAMSUNG · FJM Max HeatSamsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95105%10.523.0CEE 25CEE 26Xcel3213353367
4023AJ024BXJ3CHSAMSUNG · FJMSamsung2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7766%8.819.5CEE 25CEE 263207349915
4024AJ024BXS4CHSAMSUNG · FJM Max HeatSamsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.0CEE 25CEE 26Xcel3207349918
4025AJ024CXS4CHSAMSUNG · FJM Max HeatSamsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.85100%10.423.0CEE 25CEE 26Xcel3213353368

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy