Skip to content

CEE 2025 Tier 1 (Split ASHP): 4,801 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
48.9%
Qualifying models
4,801
Qualifying certifications
98,649
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%92% of rated models reach 45% (the lowest path) on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons70.1% · 2,244 of 3,201
2 tons57.2% · 832 of 1,454
2.5 to 3 tons42.1% · 1,109 of 2,633
3.5 to 4.5 tons25.6% · 557 of 2,174
5 tons and up16.3% · 59 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted25.5%1,174 / 4,608
Non-ducted62.2%2,064 / 3,317
Ducted and non-ducted82.3%1,563 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric260 of 40065%
Midea246 of 40860.3%
Gree241 of 40359.8%
Carrier200 of 70128.5%
Lennox148 of 37539.5%
Hisense119 of 16074.4%
Rheem117 of 29140.2%
Daikin99 of 37126.7%
Trane97 of 30931.4%
ACIQ67 of 16141.6%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 166 of 193
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
4126SHC2Z18VE2AGSLIMAIR · SHC SeriesSLIMAIR1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.5CEE 25CEE 26XcelES CC3213886038
4127SHC30VB2ABSLIMAIRwith ductless indoor unit SHM30VB2ABSLIMAIR2.5 tons30,000 Btu/h · Non-ducted1.8460%8.718.6CEE 251208447932
4128SHC30VH224VSLIMAIR · SHC Serieswith ducted air handler SHV30VE2AGSLIMAIR2.5 tons30,000 Btu/h · Ducted1.8073%8.916.2CEE 25CEE 26Xcel1217898872
4129SHC30VH2AGSLIMAIR · SHC serieswith ductless indoor unit SHM30VE2AGSLIMAIR3 tons33,000 Btu/h · Non-ducted1.8099%10.020.0CEE 25CEE 26XcelES CC1213927691
4130SHC36VH224VSLIMAIR · SHC Serieswith ducted air handler SHV36VE2AGSLIMAIR3 tons36,000 Btu/h · Ducted1.9786%9.516.0CEE 25CEE 26Xcel1217996675
4131SHC3Z27VC2AGSLIMAIR · SHC seriesSLIMAIR2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3208447951
4132SHC3Z27VE2AGSLIMAIR · SHC SeriesSLIMAIR2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%9.822.6CEE 25CEE 26XcelES CC3213886041
4133SHC4Z36VC2AGSLIMAIRSLIMAIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8065%9.623.1CEE 253208447954
4134SHC4Z36VE2AGSLIMAIR · SHC SeriesSLIMAIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%9.720.0CEE 25CEE 26XcelES CC3213886044
4135SHC5Z48VC2AGSLIMAIR · SHC SeriesSLIMAIR4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%9.521.1CEE 25CEE 263208447957
4136SHC5Z48VE2AGSLIMAIR · SHC SeriesSLIMAIR4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%10.021.2CEE 25CEE 26XcelES CC3213886047
4137SHC5Z55VC2AGSLIMAIRSLIMAIR4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8060%9.620.2CEE 253213886035
4138SHC5Z55VE2AGSLIMAIR · SHC SeriesSLIMAIR4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.520.0CEE 25CEE 26XcelES CC3213886050
4139SHCD09VC2AGSLIMAIR · SHC serieswith ductless indoor unit SHMZ09VC2AGSLIMAIR1 ton9,000 Btu/h · Non-ducted1.9094%11.626.4CEE 25CEE 26XcelES CC1208447940
4140SHCD12VC2AGSLIMAIR · SHC serieswith ductless indoor unit SHMZ12VC2AGSLIMAIR1 ton12,000 Btu/h · Non-ducted1.8992%10.523.1CEE 25CEE 26XcelES CC1208447941
4141SHCD18VC2AGSLIMAIR · SHC serieswith ductless indoor unit SHMZ18VC2AGSLIMAIR1.5 tons18,000 Btu/h · Non-ducted1.8996%10.622.0CEE 25CEE 26XcelES CC1208447942
4142SHCD24VC2AGSLIMAIR · SHC serieswith ductless indoor unit SHMZ24VC2AGSLIMAIR2 tons23,000 Btu/h · Non-ducted1.8088%10.322.3CEE 25CEE 26XcelES CC1208447943
4143SHC09VB-2HSLIMAIR TECHNOLOGIESwith ductless indoor unit SHM09VB-2DCSLIMAIR TECHNOLOGIES1 ton9,000 Btu/h · Non-ducted1.7564%8.522.0CEE 25CEE 2619060038
4144SHC12VB-2HSLIMAIR TECHNOLOGIESwith ductless indoor unit SHM12VB-2DCSLIMAIR TECHNOLOGIES1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel19060039
4145SHC18VB-2HSLIMAIR TECHNOLOGIESwith ductless indoor unit SHM18VB-2DCSLIMAIR TECHNOLOGIES1.5 tons18,000 Btu/h · Non-ducted1.8066%8.622.5CEE 25CEE 2619060040
4146SHC24VB-2HSLIMAIR TECHNOLOGIESwith ductless indoor unit SHM24VB-2DCSLIMAIR TECHNOLOGIES2 tons23,000 Btu/h · Non-ducted1.7570%8.620.5CEE 25CEE 2619060043
4147SHC30VA-2HSLIMAIR TECHNOLOGIESwith ductless indoor unit SHM30VA-2VTSLIMAIR TECHNOLOGIES2.5 tons30,000 Btu/h · Non-ducted1.7560%9.018.5CEE 2519060044
4148DHP30CSB22SSMARTFLEXwith ductless indoor unit DHP30NWB22SSMARTFLEX2.5 tons30,000 Btu/h · Non-ducted1.8177%8.520.0CEE 25CEE 26Xcel1209818482
4149DHP36CSB22SSMARTFLEXwith ductless indoor unit DHP36NWB22SSMARTFLEX3 tons33,600 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel1209818487
4150DHS18CMB22SSMARTFLEXSMARTFLEX1.5 tons18,000 Btu/h · Ducted and non-ducted1.81104%10.020.0CEE 25CEE 26Xcel2207616612

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter