Skip to content

CEE 2025 Tier 1 (Split ASHP): 4,801 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
48.9%
Qualifying models
4,801
Qualifying certifications
98,649
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%92% of rated models reach 45% (the lowest path) on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons70.1% · 2,244 of 3,201
2 tons57.2% · 832 of 1,454
2.5 to 3 tons42.1% · 1,109 of 2,633
3.5 to 4.5 tons25.6% · 557 of 2,174
5 tons and up16.3% · 59 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted25.5%1,174 / 4,608
Non-ducted62.2%2,064 / 3,317
Ducted and non-ducted82.3%1,563 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric260 of 40065%
Midea246 of 40860.3%
Gree241 of 40359.8%
Carrier200 of 70128.5%
Lennox148 of 37539.5%
Hisense119 of 16074.4%
Rheem117 of 29140.2%
Daikin99 of 37126.7%
Trane97 of 30931.4%
ACIQ67 of 16141.6%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 190 of 193
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
4726YVAHP060B21S*YORKYork5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.6158%10.520.3CEE 25CEE 263203994964
4727YZT24B21YORKwith ducted air handler AE(D,N,U)+CM36B34+TDRYork2 tons21,600 Btu/h · Ducted3.0171%7.917.6CEE 25CEE 26Xcel443212633203
4728YZT36B21YORKwith ducted air handler AE(D,N,U)+CM48E44+TDRYork2.5 tons32,600 Btu/h · Ducted2.7868%7.818.2CEE 25CEE 26712212633209
4729YZT48B21YORKwith ducted air handler AEL+D(A,C,E)60D44+TDRYork4 tons45,500 Btu/h · Ducted3.1169%8.517.3CEE 25CEE 26Xcel947212912471
4730YZV24B21YORKwith indoor coil XAMB24DE1N1+CC and furnace TM9V060B12MP12York2 tons22,600 Btu/h · Ducted1.9278%8.517.0CEE 25CEE 26Xcel19211207007
4731YZV36B21YORKwith ducted air handler AVV38CE221York3 tons33,600 Btu/h · Ducted2.2156%——CEE 25CEE 26Xcel3810309007
4732YZV48B21YORKwith ducted air handler CM50CE3A1+MVC16CN21York4 tons45,000 Btu/h · Ducted2.5178%——CEE 25CEE 26Xcel5410309024
4733YZV60B21YORKwith ducted air handler JHVVD60HE4C2N1+CCYork4.5 tons52,500 Btu/h · Ducted2.2477%8.519.0CEE 25CEE 26Xcel22211010174
4734MA-12CA22SEXTZEPHYRwith ductless indoor unit MA-12CA22SINTZEPHYR1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel1203446792
4735MA-18CA22SEXTZEPHYRwith ductless indoor unit MA-18CA22SINTZEPHYR1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26Xcel1203446802
4736ZE-09CA22SEXTZEPHYRwith ductless indoor unit ZE-09CA22SINTZEPHYR1 ton9,000 Btu/h · Non-ducted2.0780%9.022.0CEE 25CEE 26Xcel1203446791
4737ZE-09DA17EXTZEPHYRwith ductless indoor unit ZE-09DA17INTZEPHYR1 ton9,000 Btu/h · Non-ducted1.7564%8.018.5CEE 25CEE 262205128809
4738ZE-09UH24SCOZEPHYR · Hi MULTI Xtremewith ductless indoor unit ZE-09UH24SCIZEPHYR1 ton9,000 Btu/h · Non-ducted1.9496%10.525.5CEE 25CEE 26XcelES CC1208287539
4739ZE-12CA22EXTZEPHYRwith ductless indoor unit ZE-12CA22INTZEPHYR1 ton12,000 Btu/h · Non-ducted1.8580%9.521.0CEE 25CEE 26Xcel1204580064
4740ZE-12CA22SEXTZEPHYRwith ductless indoor unit ZE-12CA22SINTZEPHYR1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel1203446793
4741ZE-12UH24SCOZEPHYR · Hi MULTI Xtremewith ductless indoor unit ZE-12UH24SCIZEPHYR1 ton12,000 Btu/h · Non-ducted1.8983%9.523.5CEE 25CEE 26XcelES CC1208287541
4742ZE-18CA22EXTZEPHYRwith ductless indoor unit ZE-18CA22INTZEPHYR1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26Xcel1204580063
4743ZE-18CA22SEXTZEPHYRwith ductless indoor unit ZE-18CA22SINTZEPHYR1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26Xcel1203446803
4744ZE-18M222SCOZEPHYR · Hi MULTI XtremeZEPHYR1.5 tons18,000 Btu/h · Non-ducted and mixed (multi-zone)1.80100%9.521.0CEE 25CEE 26XcelES CC2206346128
4745ZE-18UH24SCOZEPHYRwith ductless indoor unit ZE-18UH24SCIZEPHYR1.5 tons18,000 Btu/h · Non-ducted1.8086%9.520.5CEE 25CEE 26Xcel1208287543
4746ZE-24CA22SEXTZEPHYRwith ductless indoor unit ZE-24CA22SINTZEPHYR2 tons23,000 Btu/h · Non-ducted2.1389%8.620.5CEE 25CEE 26Xcel1203446804
4747ZE-24HPBZEPHYR · Hi ULTRA HDwith ducted air handler AH-24BZEPHYR2 tons22,000 Btu/h · Ducted2.0077%9.016.5CEE 25CEE 26XcelES CC1207036640
4748ZE-24M322SCOZEPHYR · Hi MULTI XtremeZEPHYR2 tons24,000 Btu/h · Non-ducted and mixed (multi-zone)1.80100%9.122.0CEE 25CEE 26XcelES CC2206346130
4749ZE-24UH24SCOZEPHYRwith ductless indoor unit ZE-24UH24SCIZEPHYR2 tons24,000 Btu/h · Non-ducted1.7695%10.021.0CEE 25CEE 26Xcel1208287545
4750ZE-36HPBZEPHYR · Hi ULTRA HDwith ducted air handler AH-36BZEPHYR3 tons34,000 Btu/h · Ducted2.0576%9.518.0CEE 25CEE 26XcelES CC1207036642

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy