Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025 Tier 1 (Split ASHP): 4,661 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 48.4%
- Qualifying models
- 4,661
- Qualifying certifications
- 98,129
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,084 |
| 1.90 to under 2.00 | 1,248 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 469 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 529 |
| 85 to under 90% | 414 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 691 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 239 |
| 7.3 to under 7.5 | 65 |
| 7.5 to under 7.8 | 1,051 |
| 7.8 to under 8.0 | 534 |
| 8.0 to under 8.3 | 813 |
| 8.3 to under 8.5 | 123 |
| 8.5 to under 8.8 | 1,436 |
| 8.8 to under 9.0 | 268 |
| 9.0 to under 9.3 | 944 |
| 9.3 to under 9.5 | 361 |
| 9.5 to under 9.8 | 692 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 623 |
| 10.3 to under 10.5 | 171 |
| 10.5 to under 10.8 | 303 |
| 10.8 to under 11.0 | 79 |
| 11.0 to under 11.3 | 175 |
| 11.3 to under 11.5 | 85 |
| 11.5 to under 11.8 | 116 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 658 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 986 |
| 15.5 to under 16.0 | 347 |
| 16.0 to under 16.5 | 714 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 370 |
| 18.5 to under 19.0 | 277 |
| 19.0 to under 19.5 | 590 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 387 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,155 |
| 11.0 to under 11.5 | 964 |
| 11.5 to under 12.0 | 1,095 |
| 12.0 to under 12.5 | 908 |
| 12.5 to under 13.0 | 1,265 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons69.5% · 2,175 of 3,129
- 2 tons56.5% · 812 of 1,436
- 2.5–3 tons41.4% · 1,072 of 2,587
- 3.5–4.5 tons25.5% · 545 of 2,136
- 5 tons and up16.3% · 57 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 69.5% · 2,175 of 3,129 |
| 2 tons | 56.5% · 812 of 1,436 |
| 2.5–3 tons | 41.4% · 1,072 of 2,587 |
| 3.5–4.5 tons | 25.5% · 545 of 2,136 |
| 5 tons and up | 16.3% · 57 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 25.8% | 1,175 / 4,546 |
| Non-ducted | 60.4% | 1,955 / 3,236 |
| Ducted and non-ducted | 82.5% | 1,531 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Mitsubishi Electric | 253 of 373 | 67.8% |
| Midea | 242 of 402 | 60.2% |
| Gree | 233 of 395 | 59% |
| Carrier | 200 of 701 | 28.5% |
| Lennox | 144 of 313 | 46% |
| Rheem | 117 of 291 | 40.2% |
| Hisense | 103 of 159 | 64.8% |
| Daikin | 99 of 367 | 27% |
| Trane | 97 of 309 | 31.4% |
| ACIQ | 66 of 161 | 41% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 526BMS500-AAS009-1CSXHBBOSCH · Bosch Climate 5000 ductless minisplit serieswith ducted air handler BMS500-AAU009-1AHDXB | Bosch | 1 ton9,000 Btu/h · Ducted | 2.07 | 83% | 11.5 | 18.5 | CEE 25CEE 26Xcel | 1 | 204014467 |
| 527BMS500-AAS009-1CSXHCBOSCH · BMS500with ductless indoor unit BMS500-AAU009-1AHWXC | Bosch | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.97 | 88% | 11.5 | 28.1 | CEE 25CEE 26XcelES CC | 4 | 207759994 |
| 528BMS500-AAS009-1CSXRABOSCH · Bosch Climate 5000 ductless minisplit serieswith ductless indoor unit BMS500-AAU009-1AHWXB | Bosch | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.98 | 82% | 9.3 | 21.8 | CEE 25CEE 26Xcel | 2 | 203991148 |
| 529BMS500-AAS009-1CSXRCBOSCH · BMS500with ductless indoor unit BMS500-AAU009-1AHWXC | Bosch | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.19 | 86% | 12.3 | 25.5 | CEE 25CEE 26XcelES CC | 5 | 207759989 |
| 530BMS500-AAS012-0CSXRCBOSCH · BMS serieswith ductless indoor unit BMS500-AAS012-0AHWXC | Bosch | 1 ton12,000 Btu/h · Non-ducted | 2.17 | 57% | 10.0 | 23.5 | CEE 25CEE 26 | 2 | 207759988 |
| 531BMS500-AAS012-1CSXHBBOSCH · Bosch Climate 5000 ductless minisplit serieswith ducted air handler BMS500-AAU012-1AHDXB | Bosch | 1 ton12,000 Btu/h · Ducted | 1.78 | 98% | 10.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 204014468 |
| 532BMS500-AAS012-1CSXHCBOSCH · BMS500with ducted air handler BMS500-AAU012-1AHDXB | Bosch | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.96 | 97% | 10.0 | 19.5 | CEE 25CEE 26XcelES CC | 4 | 207760003 |
| 533BMS500-AAS012-1CSXRABOSCH · Bosch Climate 5000 ductless minisplit serieswith ductless indoor unit BMS500-AAU012-1AHWXB | Bosch | 1 ton12,000 Btu/h · Non-ducted | 1.87 | 71% | 8.8 | 22.3 | CEE 25CEE 26Xcel | 1 | 203991149 |
| 534BMS500-AAS012-1CSXRCBOSCH · BMS500with ductless indoor unit BMS500-AAU012-1AHWXC | Bosch | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.39 | 67% | 10.7 | 24.6 | CEE 25CEE 26XcelES CC | 4 | 207759990 |
| 535BMS500-AAS018-1CSXHCBOSCH · BMS500with ductless indoor unit BMS500-AAU018-1AHWXB | Bosch | 1.5 tons17,000 Btu/h · Ducted and non-ducted | 1.90 | 91% | 10.0 | 19.4 | CEE 25CEE 26XcelES CC | 4 | 208157118 |
| 536BMS500-AAS018-1CSXRCBOSCH · BMS500with ducted air handler BMS500-AAU018-1AHDXB | Bosch | 1.5 tons17,000 Btu/h · Ducted and non-ducted | 2.40 | 65% | 10.6 | 20.0 | CEE 25CEE 26 | 4 | 207760004 |
| 537BMS500-AAS024-1CSXHBBOSCH · Bosch Climate 5000 ductless minisplit serieswith ducted air handler BMS500-AAU024-1AHDXB | Bosch | 2 tons24,000 Btu/h · Ducted | 2.07 | 105% | 10.5 | 19.2 | CEE 25CEE 26Xcel | 1 | 204014470 |
| 538BMS500-AAS024-1CSXHCBOSCH · BMS500with ductless indoor unit BMS500-AAU024-1AHWXC | Bosch | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26XcelES CC | 4 | 207759997 |
| 539BMS500-AAS024-1CSXRABOSCH · Bosch Climate 5000 ductless minisplit serieswith ducted air handler BMS500-AAU024-1AHDXB | Bosch | 2 tons23,000 Btu/h · Ducted | 2.04 | 76% | 10.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 203991162 |
| 540BMS500-AAS024-1CSXRCBOSCH · BMS500with ducted air handler BMS500-AAU024-1AHDXB | Bosch | 2 tons23,000 Btu/h · Ducted and non-ducted | 2.30 | 80% | 11.2 | 19.0 | CEE 25CEE 26XcelES CC | 4 | 207760006 |
| 541BMS500-AAS030-1CSXRCBOSCH · BMS500with ductless indoor unit BMS500-AAU030-1AHWXC | Bosch | 2.5 tons30,000 Btu/h · Non-ducted | 1.92 | 62% | 9.0 | 20.1 | CEE 25CEE 26 | 2 | 207759998 |
| 542BOVA-24HDN1-M15GBOSCHwith ducted air handler L(E,G)M24K4 | Bosch | 2 tons23,400 Btu/h · Ducted | 2.50 | 81% | 8.1 | 15.2 | CEE 25CEE 26XcelES CC | 38 | 212507774 |
| 543BOVA-36HDN1-M15GBOSCHwith ducted air handler L(E,G)M24H4 | Bosch | 2 tons23,200 Btu/h · Ducted | 2.50 | 85% | 8.2 | 15.2 | CEE 25CEE 26XcelES CC | 128 | 212507777 |
| 544BOVA-36HDN1-M20GBOSCHwith ducted air handler AFM234+TDR | Bosch | 2 tons23,800 Btu/h · Ducted | 2.61 | 92% | 9.0 | 19.5 | CEE 25CEE 26Xcel | 208 | 212507768 |
| 545BOVA-60HDN1-M15GBOSCHwith indoor coil D(A,C,E)48B44+TDR and furnace BGH96M100C5A | Bosch | 3.5 tons42,500 Btu/h · Ducted | 2.42 | 68% | 7.8 | 16.0 | CEE 25CEE 26XcelES CC | 140 | 214063887 |
| 546BOVA-60HDN1-M20GBOSCHwith ducted air handler L(E,G)M48G4 | Bosch | 4 tons47,000 Btu/h · Ducted | 2.61 | 83% | 9.5 | 18.5 | CEE 25CEE 26Xcel | 143 | 212675690 |
| 547BOVB-36HDN1-M18MBOSCHwith ducted air handler BVA-24WN1-M18 | Bosch | 2 tons24,000 Btu/h · Ducted | 2.05 | 72% | — | — | CEE 25CEE 26Xcel | 38 | 206395964 |
| 548BOVB-36HDN1-M20GBOSCHwith ducted air handler L(E,G)M36F4 | Bosch | 3 tons34,200 Btu/h · Ducted | 2.64 | 80% | 9.5 | 19.0 | CEE 25CEE 26Xcel | 223 | 212675684 |
| 549BOVB-60HDN1-M18MBOSCHwith ducted air handler L(E,G)M36F4 | Bosch | 3 tons34,800 Btu/h · Ducted | 2.56 | 70% | 8.2 | 17.0 | CEE 25CEE 26Xcel | 213 | 212675685 |
| 550BOVB-60HDN1-M20GBOSCHwith ducted air handler AE(D,N,U)+DM59A44+TDR | Bosch | 3.5 tons43,000 Btu/h · Ducted | 2.50 | 84% | 9.1 | 18.2 | CEE 25CEE 26Xcel | 204 | 214094107 |