Skip to content

CEE 2025 Tier 1 (Split ASHP): 4,661 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
48.4%
Qualifying models
4,661
Qualifying certifications
98,129
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,755 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,084
1.90 to under 2.001,248
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30469
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,747 rated models · median 69%92% of rated models reach 45% (the lowest path) on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%529
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF29,260 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8691
6.8 to under 7.067
7.0 to under 7.3239
7.3 to under 7.565
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3813
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3944
9.3 to under 9.5361
9.5 to under 9.8692
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,260 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5986
15.5 to under 16.0347
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER29,260 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0387
10.0 to under 10.5900
10.5 to under 11.01,155
11.0 to under 11.5964
11.5 to under 12.01,095
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons69.5% · 2,175 of 3,129
2 tons56.5% · 812 of 1,436
2.5–3 tons41.4% · 1,072 of 2,587
3.5–4.5 tons25.5% · 545 of 2,136
5 tons and up16.3% · 57 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted25.8%1,175 / 4,546
Non-ducted60.4%1,955 / 3,236
Ducted and non-ducted82.5%1,531 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric253 of 37367.8%
Midea242 of 40260.2%
Gree233 of 39559%
Carrier200 of 70128.5%
Lennox144 of 31346%
Rheem117 of 29140.2%
Hisense103 of 15964.8%
Daikin99 of 36727%
Trane97 of 30931.4%
ACIQ66 of 16141%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 31 of 187
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
751DLCPRBH18AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFPHBH18XAKCarrier1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC9207826644
752DLCSRBH06AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFSHCH06XAKCarrier0.5 tons6,000 Btu/h · Non-ducted2.09107%13.626.5CEE 25CEE 26XcelES CC37208447621
753DLCSRBH09AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFSHCH09XAKCarrier1 ton9,000 Btu/h · Ducted and non-ducted2.0088%11.528.1CEE 25CEE 26XcelES CC73208447617
754DLCSRBH12AAJARCOAIRE · DLC-serieswith ductless indoor unit DLFSHCH12XAJCarrier1 ton12,000 Btu/h · Non-ducted2.1757%10.023.5CEE 25CEE 2628208447620
755DLCSRBH12AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFSFBH12XAKCarrier1 ton12,000 Btu/h · Ducted and non-ducted1.9999%10.724.2CEE 25CEE 26XcelES CC82209948191
756DLCSRBH18AAKARCOAIRE · DLC-serieswith ducted air handler DLFSDAH18XHKCarrier1.5 tons17,500 Btu/h · Ducted and non-ducted2.2095%10.818.0CEE 25CEE 26XcelES CC160211132679
757DLCSRBH24AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFSHCH24XAKCarrier2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC132208447615
758DLCSRBH30AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFSHCH30XAKCarrier2.5 tons30,000 Btu/h · Ducted and non-ducted1.9262%9.020.1CEE 25CEE 2637208447618
759DLCSRBH30AAK11CARRIER · DLC-serieswith ductless indoor unit DHMAHBQ30XA3Carrier2.5 tons30,000 Btu/h · Ducted and non-ducted1.9262%9.020.1CEE 25CEE 2638216091730
760DLCURAH18AAKDAY & NIGHTwith ducted air handler L(E,F)W30B4Carrier1.5 tons17,300 Btu/h · Ducted2.7066%7.515.0CEE 25107215402623
761DLCURAH18ABKTEMPSTARwith indoor coil D(A,C,E)24B44+TDR and furnace *80VTL0451412BCarrier1.5 tons17,700 Btu/h · Ducted2.6170%8.516.5CEE 25CEE 26CEE AdvXcelDOEES CC6,123213820984
762DLCURAH24AAKTEMPSTARwith indoor coil D(A,C,E)24B44+TDR and furnace *80MS(N,L)0451412ACarrier2 tons22,800 Btu/h · Ducted2.9281%8.116.3CEE 25CEE 26CEE AdvXcelDOEES CC11,115213821016
763DLCURAH24ABKTEMPSTARwith indoor coil D(A,C,E)30C44+TDR and furnace *92ESN0802120ACarrier2 tons23,800 Btu/h · Ducted3.0373%8.517.0CEE 25CEE 26CEE AdvXcelDOEES CC11,258213204888
764DLCURAH30ABKTEMPSTARwith indoor coil D(A,C,E)30C44+TDR and furnace *80ES(N,L)0901714ACarrier2.5 tons29,000 Btu/h · Ducted2.8070%8.115.2CEE 25CEE 26XcelES CC9,104213205173
765DLCURAH36ABKTEMPSTARwith indoor coil D(A,C,E)36B34+TDR and furnace *96MSN1002120ACarrier3 tons33,800 Btu/h · Ducted2.7577%8.516.4CEE 25CEE 26XcelES CC12,427213821643
766DLCURAH48ABKTEMPSTAR · HORIZONTAL VS HPwith indoor coil EN(A,D)4X48L24 and furnace *96VSN1202422BCarrier4 tons46,500 Btu/h · Ducted2.1635%7.514.5CEE 25CEE 26XcelES CC4,096212974611
767DLCVRAH09AAJARCOAIREwith ductless indoor unit DLFVHAH09XAJCarrier1 ton9,000 Btu/h · Non-ducted1.8865%9.017.0CEE 25CEE 269205967966
768DLCVRAH09AAKARCOAIRE · DLC-serieswith ductless indoor unit DLFVHAH09XAKCarrier1 ton9,000 Btu/h · Non-ducted2.1071%8.818.5CEE 25CEE 26XcelES CC18205967968
769GH7TAN424**AA*CARRIER · 2-STAGE 17 SEER HPwith indoor coil CAP**3721AL and furnace 59SU5B100M21**22Carrier2 tons23,600 Btu/h · Ducted2.4045%8.117.0CEE 253,107212321098
770GH7TAN436**AA*CARRIER · 2-STAGE 17 SEER HPwith ducted air handler FT4BNBD60LCarrier3 tons36,000 Btu/h · Ducted2.3450%8.117.0CEE 25CEE 263,243213925443
771GH7TAN448**AA*CARRIER · 2-STAGE 17 SEER HPwith ducted air handler F54AA*C48LCarrier4 tons46,500 Btu/h · Ducted2.3451%8.116.0CEE 25CEE 262,335213310402
772GH7TAN460**AA*CARRIER · 2-STAGE 17 SEER HPwith ducted air handler F54AA*D60LCarrier5 tons57,000 Btu/h · Ducted2.3451%8.116.0CEE 25CEE 261,276213310424
773H4H7T24*K*AAA*HEIL · Mainline 17 SEER2 HPwith indoor coil EA*4X37L21A and furnace *95MSU1002122ACarrier2 tons23,600 Btu/h · Ducted2.4045%8.117.0CEE 253,274212321103
774H4H7T36*K*AAA*HEIL · Mainline 17 SEER2 HPwith ducted air handler FCMB4B48L0C*+WALLCONCarrier3 tons34,400 Btu/h · Ducted2.2651%8.116.0CEE 25CEE 263,214213301813
775H4H7T48*K*AAA*HEIL · Mainline 17 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCONCarrier4 tons47,500 Btu/h · Ducted2.4251%8.117.5CEE 25CEE 261,720213301829

Explore qualifying models by COP at 5°F