Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025 Tier 1 (Split ASHP): 4,665 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 48.1%
- Qualifying models
- 4,665
- Qualifying certifications
- 98,137
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 123 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 115 |
| 1.70 to under 1.80 | 716 |
| 1.80 to under 1.90 | 2,089 |
| 1.90 to under 2.00 | 1,247 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 607 |
| 2.20 to under 2.30 | 477 |
| 2.30 to under 2.40 | 345 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 366 |
| 40 to under 45% | 200 |
| 45 to under 50% | 286 |
| 50 to under 55% | 599 |
| 55 to under 60% | 783 |
| 60 to under 65% | 885 |
| 65 to under 70% | 799 |
| 70 to under 75% | 1,049 |
| 75 to under 80% | 488 |
| 80 to under 85% | 537 |
| 85 to under 90% | 414 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 387 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 711 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 263 |
| 7.3 to under 7.5 | 67 |
| 7.5 to under 7.8 | 1,051 |
| 7.8 to under 8.0 | 534 |
| 8.0 to under 8.3 | 813 |
| 8.3 to under 8.5 | 123 |
| 8.5 to under 8.8 | 1,436 |
| 8.8 to under 9.0 | 268 |
| 9.0 to under 9.3 | 947 |
| 9.3 to under 9.5 | 363 |
| 9.5 to under 9.8 | 693 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 623 |
| 10.3 to under 10.5 | 171 |
| 10.5 to under 10.8 | 303 |
| 10.8 to under 11.0 | 79 |
| 11.0 to under 11.3 | 175 |
| 11.3 to under 11.5 | 85 |
| 11.5 to under 11.8 | 116 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 678 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 1,004 |
| 15.5 to under 16.0 | 355 |
| 16.0 to under 16.5 | 714 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 371 |
| 18.5 to under 19.0 | 279 |
| 19.0 to under 19.5 | 593 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 388 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,175 |
| 11.0 to under 11.5 | 983 |
| 11.5 to under 12.0 | 1,096 |
| 12.0 to under 12.5 | 918 |
| 12.5 to under 13.0 | 1,266 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons69.5% · 2,175 of 3,130
- 2 tons56.5% · 813 of 1,440
- 2.5–3 tons41.2% · 1,074 of 2,606
- 3.5–4.5 tons25.3% · 546 of 2,161
- 5 tons and up15.9% · 57 of 358
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 69.5% · 2,175 of 3,130 |
| 2 tons | 56.5% · 813 of 1,440 |
| 2.5–3 tons | 41.2% · 1,074 of 2,606 |
| 3.5–4.5 tons | 25.3% · 546 of 2,161 |
| 5 tons and up | 15.9% · 57 of 358 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 25.5% | 1,174 / 4,597 |
| Non-ducted | 60.4% | 1,955 / 3,236 |
| Ducted and non-ducted | 82.5% | 1,536 / 1,862 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Mitsubishi Electric | 253 of 373 | 67.8% |
| Midea | 242 of 402 | 60.2% |
| Gree | 233 of 395 | 59% |
| Carrier | 200 of 701 | 28.5% |
| Lennox | 148 of 371 | 39.9% |
| Rheem | 117 of 291 | 40.2% |
| Hisense | 103 of 159 | 64.8% |
| Daikin | 99 of 367 | 27% |
| Trane | 97 of 309 | 31.4% |
| ACIQ | 66 of 161 | 41% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 801RAV-SP302AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM302UTP-UL | Carrier | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.50 | 71% | 11.2 | 23.7 | CEE 25CEE 26Xcel | 4 | 208447324 |
| 802RAV-SP362AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM362UTP-UL | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.47 | 70% | 11.1 | 24.3 | CEE 25CEE 26Xcel | 4 | 208447327 |
| 803RAV-SP422AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM422CTP-UL | Carrier | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.15 | 71% | 10.7 | 19.6 | CEE 25CEE 26Xcel | 3 | 208447330 |
| 804RAV-SP482AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM482UTP-UL | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.02 | 71% | 9.8 | 22.4 | CEE 25CEE 26Xcel | 3 | 208429509 |
| 805T4H7T24*K*AAA*TEMPSTARwith indoor coil D(A,C,E)30C44+TDR and furnace *80CTL0901716A | Carrier | 2 tons23,800 Btu/h · Ducted | 3.03 | 50% | 7.9 | 16.0 | CEE 25CEE 26 | 1,200 | 213201692 |
| 806T4H7T36*K*AAA*TEMPSTARwith indoor coil D(A,C,E)36D44+TDR and furnace *96VTN1002122A | Carrier | 3 tons34,000 Btu/h · Ducted | 2.91 | 56% | 8.1 | 16.4 | CEE 25CEE 26 | 1,189 | 213202322 |
| 807T4H7T48*K*AAA*TEMPSTAR · Mainline 17 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCON | Carrier | 4 tons47,500 Btu/h · Ducted | 2.42 | 51% | 8.1 | 17.5 | CEE 25CEE 26 | 586 | 213301836 |
| 808T4H7T60*K*AAA*TEMPSTAR · Mainline 17 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCON | Carrier | 5 tons57,000 Btu/h · Ducted | 2.38 | 52% | 8.0 | 16.5 | CEE 25CEE 26 | 380 | 213301844 |
| 809TVH825GKA2*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716A | Carrier | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 505 | 204456507 |
| 810TVH825GKA3*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X37L21A*+WALLCON and furnace *80CTL0901716A | Carrier | 2 tons24,600 Btu/h · Ducted | 2.24 | 86% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 759 | 206766040 |
| 811TVH837GKA**TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120A | Carrier | 2.5 tons31,800 Btu/h · Ducted | 2.10 | 83% | 7.5 | 17.0 | CEE 25CEE 26Xcel | 581 | 204299604 |
| 812TVH837GKA**+TSTATTEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X37L21A and furnace *80VSL0902120B | Carrier | 3 tons33,000 Btu/h · Ducted | 2.00 | 52% | 8.5 | 15.5 | CEE 25CEE 26 | 606 | 214378794 |
| 813TVH837GKA2*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122A | Carrier | 3 tons33,200 Btu/h · Ducted | 2.24 | 86% | 8.5 | 18.0 | CEE 25CEE 26Xcel | 598 | 210470538 |
| 814TVH837GKA2*+TSTATTEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A and furnace OMV154L20A | Carrier | 3 tons33,000 Btu/h · Ducted | 2.12 | 60% | 8.1 | 17.0 | CEE 25CEE 26 | 647 | 210462023 |
| 815TVH848GKA**TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422A | Carrier | 4 tons45,500 Btu/h · Ducted | 2.08 | 64% | 8.5 | 16.5 | CEE 25 | 180 | 204301462 |
| 816TVH848GKA2*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CSU0802120A | Carrier | 4 tons45,500 Btu/h · Ducted | 2.32 | 71% | 8.5 | 17.0 | CEE 25CEE 26Xcel | 201 | 206774828 |
| 817W4H7T24*K*AAA*GRANDAIRE · 2-STAGE 17 SEER HPwith indoor coil WLA*254BA and furnace WFEU060B048B | Carrier | 2 tons23,000 Btu/h · Ducted | 2.38 | 45% | 7.8 | 16.0 | CEE 25 | 706 | 212320232 |
| 818W4H7T36*K*AAA*GRANDAIRE · 2-STAGE 17 SEER HPwith ducted air handler WBGL604BD | Carrier | 3 tons36,000 Btu/h · Ducted | 2.34 | 50% | 8.1 | 17.0 | CEE 25CEE 26 | 543 | 213925469 |
| 819W4H7T48*K*AAA*GRANDAIRE · 2-STAGE 17 SEER HPwith ducted air handler WBGL604BD | Carrier | 4 tons46,500 Btu/h · Ducted | 2.32 | 49% | 8.1 | 17.5 | CEE 25CEE 26 | 332 | 213307858 |
| 820W4H7T60*K*AAA*GRANDAIRE · 2-STAGE 17 SEER HPwith ducted air handler WBGL604BD | Carrier | 4.5 tons56,500 Btu/h · Ducted | 2.30 | 50% | 8.1 | 16.5 | CEE 25CEE 26 | 159 | 213307860 |
| 821WDLCURAH18AAKGrandairewith ducted air handler WDLFUAAH18XAK | Carrier | 1.5 tons18,000 Btu/h · Ducted | 2.00 | 61% | 8.8 | 17.0 | CEE 25 | 2 | 209862127 |
| 822WDLCURAH18ABKGRANDAIREwith ducted air handler FMA4X18**AL | Carrier | 1.5 tons17,400 Btu/h · Ducted | 2.44 | 108% | 8.5 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 286 | 211264940 |
| 823WDLCURAH24AAKGRANDAIREwith indoor coil WLN(C,W)364BA and furnace WFET045A036A | Carrier | 2 tons23,600 Btu/h · Ducted | 2.32 | 71% | 8.0 | 16.0 | CEE 25CEE 26XcelES CC | 504 | 212971109 |
| 824WDLCURAH24ABKGRANDAIREwith indoor coil WLA*244BA and furnace WFST060B048A | Carrier | 2 tons23,200 Btu/h · Ducted | 2.34 | 73% | 8.5 | 16.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 519 | 213076381 |
| 825WDLCURAH30ABKGRANDAIREwith indoor coil WLN(C,W)424CA and furnace WFAX080B048B | Carrier | 2.5 tons29,600 Btu/h · Ducted | 2.30 | 79% | 8.0 | 15.0 | CEE 25CEE 26XcelES CC | 463 | 212984564 |