CEE 2025 Tier 1 (Split ASHP): 4,663 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
48.4%
Qualifying models
4,663
Qualifying certifications
98,128
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%92% of rated models reach 45% (the lowest path) on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF29,263 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8691
6.8 to under 7.067
7.0 to under 7.3239
7.3 to under 7.565
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3814
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3946
9.3 to under 9.5361
9.5 to under 9.8692
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,263 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5987
15.5 to under 16.0347
16.0 to under 16.5716
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER29,263 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,156
11.0 to under 11.5964
11.5 to under 12.01,096
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons69.5% · 2,176 of 3,130
2 tons56.6% · 813 of 1,437
2.5–3 tons41.4% · 1,072 of 2,588
3.5–4.5 tons25.5% · 545 of 2,136
5 tons and up16.3% · 57 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted25.9%1,177 / 4,549
Non-ducted60.4%1,955 / 3,236
Ducted and non-ducted82.5%1,531 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric253 of 37367.8%
Midea242 of 40260.2%
Gree233 of 39559%
Carrier200 of 70128.5%
Lennox144 of 31346%
Rheem117 of 29140.2%
Hisense103 of 15964.8%
Daikin99 of 36727%
Trane97 of 30931.4%
ACIQ66 of 16141%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 6 of 187
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
126DLCURAH18ABKACIQ · HORIZONTAL VS HPwith ducted air handler FMA4X18**ALACIQ1.5 tons17,400 Btu/h · Ducted2.44108%8.516.0CEE 25CEE 26CEE AdvXcelDOE35213072380
127DLCURAH24AAKACIQ · HORIZONTAL VS HPwith ducted air handler FMA4X30**ALACIQ2 tons25,800 Btu/h · Ducted2.0263%9.016.5CEE 2557213073177
128DLCURAH24ABKACIQ · HORIZONTAL VS HPwith indoor coil EA*4X24L17A and furnace OLV098A12ACIQ2 tons23,000 Btu/h · Ducted2.1898%8.516.0CEE 25CEE 26Xcel60213069679
129DLCURAH36ABKACIQ · HORIZONTAL VS HPwith indoor coil EA*4X37L21A and furnace *80ESU0401712AACIQ3 tons38,000 Btu/h · Ducted2.1689%8.514.5CEE 25CEE 26Xcel65213069285
130ES-18Z-M2BACIQ · ES SERIESACIQ1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.522.9CEE 25CEE 26XcelES CC3210857383
131ES-27Z-M3BACIQ · ES SERIESACIQ2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0068%9.524.6CEE 25CEE 263210857386
132ES-36Z-M4BACIQ · ES SERIESACIQ3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8068%9.523.9CEE 25CEE 263210857389
133ES-48Z-M5BACIQ · ES SERIESACIQ4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%8.723.4CEE 25CEE 263210857392
134ES-55Z-M5BACIQACIQ4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8060%9.121.3CEE 253210857395
135H4H7T24*K*AAA*ACIQwith ducted air handler C(A,C,D,E)24B44+TDRACIQ2 tons21,600 Btu/h · Ducted2.6153%7.514.3CEE 25316214604525
136H4H7T36*K*AAA*ACIQ · Mainline 17 SEER2 HPwith indoor coil EHD4X48AAL and furnace *80MSU0601716AACIQ3 tons34,200 Btu/h · Ducted2.2450%7.515.2CEE 25CEE 26417213073772
137H4H7T48*K*AAA*ACIQwith ducted air handler C(A,C,D,E)48D34+TDRACIQ3.5 tons44,000 Btu/h · Ducted2.6358%7.514.3CEE 25CEE 26198214604528
138H4H7T60*K*AAA*ACIQwith ducted air handler C(A,C,D,E)60B34+TDRACIQ4.5 tons52,000 Btu/h · Ducted2.6461%7.514.3CEE 25CEE 26100214604529
139HVH825GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716AACIQ2 tons24,400 Btu/h · Ducted2.0478%8.517.5CEE 25CEE 26Xcel156213062589
140HVH825GKA3*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716AACIQ2 tons24,400 Btu/h · Ducted2.0478%8.517.5CEE 25CEE 26Xcel360213062931
141HVH837GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120AACIQ2.5 tons31,800 Btu/h · Ducted2.1083%7.517.0CEE 25CEE 26Xcel223213062483
142HVH837GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122AACIQ3 tons33,200 Btu/h · Ducted2.02131%8.518.0CEE 25CEE 26Xcel240213067169
143HVH837GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X61L24A and furnace OMV154L20AACIQ3 tons33,000 Btu/h · Ducted2.1260%8.117.0CEE 25CEE 2674213066907
144HVH848GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422AACIQ4 tons45,500 Btu/h · Ducted2.0864%8.516.5CEE 2558213062547
145HVH848GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422AACIQ4 tons45,500 Btu/h · Ducted2.0864%8.516.5CEE 2558213063446
146N4H7T24*K*AAA*ACIQ · 2-STAGE 17 SEER HPwith indoor coil EA*4X37L21A and furnace *95MSU1002122AACIQ2 tons23,600 Btu/h · Ducted2.4045%8.117.0CEE 25308213081137
147N4H7T36*K*AAA*ACIQ · 2-STAGE 17 SEER HPwith indoor coil EHD4X48AAL and furnace *80MSU0601716AACIQ3 tons33,800 Btu/h · Ducted2.2450%7.514.5CEE 25415213073771
148N4H7T48*K*AAA*ACIQ · 2-STAGE 17 SEER HPwith ducted air handler FVM4X60***LACIQ4 tons46,500 Btu/h · Ducted2.3049%8.116.0CEE 25190213063509
149N4H7T60*K*AAA*ACIQ · 2-STAGE 17 SEER HPwith indoor coil EHD4X60AAL and furnace *80MSU0802120AACIQ4.5 tons54,500 Btu/h · Ducted2.2851%7.514.5CEE 25CEE 2696213073843
150SC-09ZPL-HP230ACIQwith ductless indoor unit SC-09WPL-HP230ACIQ1 ton9,000 Btu/h · Non-ducted1.91144%11.027.0CEE 25CEE 26Xcel1208650735

Explore qualifying models by COP at 5°F