Skip to content

CEE 2026 Tier 1 (Split ASHP): 4,390 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
45.5%
Qualifying models
4,390
Qualifying certifications
87,783
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%88% of rated models reach 50% (the lowest path) on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF29,263 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8691
6.8 to under 7.067
7.0 to under 7.3239
7.3 to under 7.565
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3814
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3946
9.3 to under 9.5361
9.5 to under 9.8692
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,263 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5987
15.5 to under 16.0347
16.0 to under 16.5716
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER29,263 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,156
11.0 to under 11.5964
11.5 to under 12.01,096
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons67% · 2,096 of 3,130
2 tons52.9% · 760 of 1,437
2.5–3 tons38.3% · 992 of 2,588
3.5–4.5 tons22.7% · 485 of 2,136
5 tons and up16.3% · 57 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted23.6%1,073 / 4,549
Non-ducted57.5%1,862 / 3,236
Ducted and non-ducted78.4%1,455 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric248 of 37366.5%
Midea230 of 40257.2%
Gree223 of 39556.5%
Carrier179 of 70125.5%
Lennox141 of 31345%
Rheem114 of 29139.2%
Hisense103 of 15964.8%
Daikin94 of 36725.6%
Trane81 of 30926.2%
Fujitsu62 of 16437.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 11 of 176
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
251ACSH1823VM2-DAIRDACHwith ductless indoor unit AIWH1800VM2-DAIRDACH1.5 tons18,000 Btu/h · Non-ducted2.3870%10.323.7CEE 25CEE 26Xcel2209948207
252ACSH2421VM2-DAIRDACHwith ductless indoor unit AIWH2400VM2-DAIRDACH2 tons24,000 Btu/h · Non-ducted1.9264%9.021.0CEE 25CEE 261209948204
253AMSH1800VM1-DAIRDACHAIRDACH1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8674%10.221.0CEE 25CEE 26Xcel3210474671
254AMSH2700VM1-DAIRDACHAIRDACH2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0067%9.221.0CEE 25CEE 26Xcel3210474675
255AMSH3600VM1-DAIRDACHAIRDACH3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%9.623.1CEE 25CEE 263210474677
256AMSH4800VM1-DAIRDACHAIRDACH4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8071%9.521.1CEE 25CEE 26Xcel3210474680
257GXH12(3.5)LSK4DH2AireForcewith ductless indoor unit GKH12(3.5)FMK4DH1AireForce1 ton12,000 Btu/h · Non-ducted1.9077%8.524.0CEE 25CEE 26XcelES CC2212925552
258GXH18(5.3)FMK4DH-1AireForce · Flex MatchAireForce1.5 tons17,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2176%10.021.0CEE 25CEE 26XcelES CC3211635192
259GXH18(5.3)LSK4DH2AireForcewith ductless indoor unit GKH18(5.3)FMK4DH1AireForce1.5 tons18,000 Btu/h · Non-ducted1.9381%8.519.0CEE 25CEE 26Xcel2212925555
260GXH24-36MSK4DHAireForce · Ultra Side Dischargewith ducted air handler GMH24-**MSK4DH1AireForce2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26XcelES CC4206724404
261GXH24(7.0)FMK4DH-1AireForce · Flex MatchAireForce2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.0CEE 25CEE 26XcelES CC3211635193
262GXH24(7.0)LSK4DHAireForcewith ductless indoor unit GHH24(7.0)LUK4DHAireForce2 tons22,000 Btu/h · Non-ducted1.7583%8.520.0CEE 25CEE 26Xcel1202534242
263GXH30(8.8)FMK4DH-1AireForce · Flex MatchAireForce2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8476%10.021.0CEE 25CEE 26XcelES CC3211635194
264GXH30(8.8)LSK4DH2AireForcewith ductless indoor unit GHH30(8.8)LUK4DH2AireForce2.5 tons30,000 Btu/h · Non-ducted1.8177%8.520.0CEE 25CEE 26Xcel1211635190
265GXH36(10.6)FMK4DH-1AireForce · Flex MatchAireForce3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8290%10.021.0CEE 25CEE 26XcelES CC3211635195
266GXH36(10.6)LSK4DH2AireForcewith ductless indoor unit GHH36(10.6)LUK4DH2AireForce3 tons33,600 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel1211635191
267GXH42(12.3)FMK4DH-1AireForce · Flex MatchAireForce3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9281%10.021.0CEE 25CEE 26XcelES CC3211635196
268GXH48-60MSK4DHAireForce · Ultra Side Dischargewith ducted air handler GMH48-**MSK4DH1AireForce4 tons48,000 Btu/h · Ducted1.8081%9.017.0CEE 25CEE 26XcelES CC4206724406
269GXH12(3.5)LSK4DH2AIRTEMPwith ductless indoor unit GKH12(3.5)FMK4DH1AIRTEMP1 ton12,000 Btu/h · Non-ducted1.9077%8.524.0CEE 25CEE 26XcelES CC2212925554
270GXH18(5.3)FMK4DH-1AIRTEMP · Flex MatchAIRTEMP1.5 tons17,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2176%10.021.0CEE 25CEE 26XcelES CC3210276805
271GXH18(5.3)LSK4DH2AIRTEMPwith ductless indoor unit GKH18(5.3)FMK4DH1AIRTEMP1.5 tons18,000 Btu/h · Non-ducted1.9381%8.519.0CEE 25CEE 26Xcel2212925557
272GXH24-36MSK4DHAIRTEMP · Ultra Side Dischargewith ducted air handler GMH24-**MSK4DH1AIRTEMP2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26XcelES CC6206724408
273GXH24(7.0)FMK4DH-1AIRTEMP · Flex MatchAIRTEMP2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.0CEE 25CEE 26XcelES CC3210276806
274GXH24(7.0)LSK4DHAIRTEMPwith ductless indoor unit GHH24(7.0)LUK4DHAIRTEMP2 tons22,000 Btu/h · Non-ducted1.7583%8.520.0CEE 25CEE 26Xcel1202443312
275GXH30(8.8)FMK4DH-1AIRTEMP · Flex MatchAIRTEMP2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8476%10.021.0CEE 25CEE 26XcelES CC3210276807

Explore qualifying models by COP at 5°F