Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026 Tier 1 (Split ASHP): 4,390 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 45.5%
- Qualifying models
- 4,390
- Qualifying certifications
- 87,783
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,085 |
| 1.90 to under 2.00 | 1,249 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 470 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 531 |
| 85 to under 90% | 415 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 691 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 239 |
| 7.3 to under 7.5 | 65 |
| 7.5 to under 7.8 | 1,051 |
| 7.8 to under 8.0 | 534 |
| 8.0 to under 8.3 | 814 |
| 8.3 to under 8.5 | 123 |
| 8.5 to under 8.8 | 1,436 |
| 8.8 to under 9.0 | 268 |
| 9.0 to under 9.3 | 946 |
| 9.3 to under 9.5 | 361 |
| 9.5 to under 9.8 | 692 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 623 |
| 10.3 to under 10.5 | 171 |
| 10.5 to under 10.8 | 303 |
| 10.8 to under 11.0 | 79 |
| 11.0 to under 11.3 | 175 |
| 11.3 to under 11.5 | 85 |
| 11.5 to under 11.8 | 116 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 658 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 987 |
| 15.5 to under 16.0 | 347 |
| 16.0 to under 16.5 | 716 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 370 |
| 18.5 to under 19.0 | 277 |
| 19.0 to under 19.5 | 590 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 388 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,156 |
| 11.0 to under 11.5 | 964 |
| 11.5 to under 12.0 | 1,096 |
| 12.0 to under 12.5 | 908 |
| 12.5 to under 13.0 | 1,265 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons67% · 2,096 of 3,130
- 2 tons52.9% · 760 of 1,437
- 2.5–3 tons38.3% · 992 of 2,588
- 3.5–4.5 tons22.7% · 485 of 2,136
- 5 tons and up16.3% · 57 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 67% · 2,096 of 3,130 |
| 2 tons | 52.9% · 760 of 1,437 |
| 2.5–3 tons | 38.3% · 992 of 2,588 |
| 3.5–4.5 tons | 22.7% · 485 of 2,136 |
| 5 tons and up | 16.3% · 57 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 23.6% | 1,073 / 4,549 |
| Non-ducted | 57.5% | 1,862 / 3,236 |
| Ducted and non-ducted | 78.4% | 1,455 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Mitsubishi Electric | 248 of 373 | 66.5% |
| Midea | 230 of 402 | 57.2% |
| Gree | 223 of 395 | 56.5% |
| Carrier | 179 of 701 | 25.5% |
| Lennox | 141 of 313 | 45% |
| Rheem | 114 of 291 | 39.2% |
| Hisense | 103 of 159 | 64.8% |
| Daikin | 94 of 367 | 25.6% |
| Trane | 81 of 309 | 26.2% |
| Fujitsu | 62 of 164 | 37.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 301MOX330-09HFN1-MY5WAlsetria · MOX Serieswith ductless indoor unit MSEPB-09HRFN1-MY5W(GA) | Alsetria | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.97 | 88% | 11.5 | 28.1 | CEE 25CEE 26XcelES CC | 4 | 208121901 |
| 302MOX330-12HFN1-MW5WAlsetria · MOX Serieswith ducted air handler MTIU-12HWFN1-M | Alsetria | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.96 | 97% | 10.0 | 19.5 | CEE 25CEE 26XcelES CC | 4 | 211644038 |
| 303MOX330-18HFN1-MS0WAlsetria · MOX Serieswith ductless indoor unit MSAG11C-18HRDN1-MS0W | Alsetria | 1.5 tons18,000 Btu/h · Non-ducted | 2.07 | 62% | 8.7 | 19.5 | CEE 25CEE 26 | 1 | 208121884 |
| 304MOX430-17HFN1-MT0WAlsetria · MOX Serieswith ducted air handler MVC-18HWFN1-MW(GA) | Alsetria | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.00 | 89% | 9.6 | 17.6 | CEE 25CEE 26XcelES CC | 5 | 211644106 |
| 305MOX430-18HFN1-MT2Q1WAlsetria · MOX Serieswith ductless indoor unit MSABE-18HRFN1-MT2Q1W | Alsetria | 1.5 tons18,000 Btu/h · Non-ducted | 2.05 | 65% | 9.8 | 22.7 | CEE 25CEE 26 | 1 | 208121893 |
| 306MOX430-18HFN1-MU0WAlsetria · MOX Serieswith ducted air handler MTIU-18HWFN1-M | Alsetria | 1.5 tons17,000 Btu/h · Ducted and non-ducted | 2.40 | 65% | 10.6 | 20.0 | CEE 25CEE 26XcelES CC | 4 | 211644026 |
| 307MOX430U-18HFN1-MAlsetria · MOX Serieswith ducted air handler MVBE-18HWFN1-MM3E | Alsetria | 1.5 tons18,000 Btu/h · Ducted | 2.30 | 99% | 10.8 | 19.3 | CEE 25CEE 26XcelES CC | 2 | 213307910 |
| 308MOX430U-24HFN1-MR0Alsetria · MOX Serieswith ducted air handler MVC-24HWFN1-M | Alsetria | 2 tons24,000 Btu/h · Ducted | 2.10 | 75% | 9.2 | 17.0 | CEE 25CEE 26XcelES CC | 1 | 208130386 |
| 309MOX630-36HFN1-M3XAlsetria · MOX Serieswith ducted air handler MVB-36B23T4N1 | Alsetria | 3 tons35,000 Btu/h · Ducted | 1.80 | 83% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 3 | 213386486 |
| 310AAG21-09H1BApooDr · AA Serieswith ductless indoor unit AAG21-09H1A | ApooDr | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.1 | 21.5 | CEE 25CEE 26XcelES CC | 1 | 209157081 |
| 311AAG21-09H220V1BApooDr · AA Serieswith ductless indoor unit AAG21-09H220V1A | ApooDr | 1 ton9,000 Btu/h · Non-ducted | 1.99 | 70% | 9.4 | 21.7 | CEE 25CEE 26XcelES CC | 1 | 209157083 |
| 312AAG21-12H220V1BApooDrwith ductless indoor unit AAG21-12H220V1A | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 1.79 | 67% | 9.2 | 21.4 | CEE 25CEE 26 | 1 | 209157084 |
| 313AAG21-18H1BApooDr · AA Serieswith ductless indoor unit AAG21-18H1A | ApooDr | 1.5 tons18,000 Btu/h · Non-ducted | 2.07 | 62% | 8.7 | 19.5 | CEE 25CEE 26 | 1 | 209157085 |
| 314AES19-09H1BApooDrwith ductless indoor unit AES19-09H1A | ApooDr | 1 ton9,000 Btu/h · Non-ducted | 1.75 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 212390864 |
| 315AES19-09H220V1BApooDrwith ductless indoor unit AES19-09H220V1A | ApooDr | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 212390866 |
| 316AES19-12H1AApooDrwith ductless indoor unit AES19-12H1B | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 211694638 |
| 317AES19-12H1BApooDrwith ductless indoor unit AES19-12H1A | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 212390865 |
| 318AES19-12H220V1AApooDrwith ductless indoor unit AES19-12H220V1B | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 211694640 |
| 319AES19-12H220V1BApooDrwith ductless indoor unit AES19-12H220V1A | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 212390867 |
| 320AGN24-09H1BApooDr · AG Serieswith ductless indoor unit AGN24-09H1A | ApooDr | 1 ton9,000 Btu/h · Non-ducted | 2.07 | 69% | 9.8 | 23.0 | CEE 25CEE 26 | 1 | 209157089 |
| 321AGN24-09H220V1BApooDr · AG Serieswith ductless indoor unit AGN24-09H220V1A | ApooDr | 1 ton9,000 Btu/h · Non-ducted | 2.22 | 86% | 11.6 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 209157090 |
| 322AGN24-12H1BApooDr · AG Serieswith ductless indoor unit AGN24-12H1A | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 2.07 | 56% | 10.4 | 22.7 | CEE 25CEE 26 | 1 | 209157091 |
| 323AGN24-12H220V1BApooDr · AG Serieswith ductless indoor unit AGN24-12H220V1A | ApooDr | 1 ton12,000 Btu/h · Non-ducted | 2.25 | 74% | 10.8 | 23.1 | CEE 25CEE 26XcelES CC | 1 | 209157092 |
| 324AGN24-18H1BApooDr · AG Serieswith ductless indoor unit AGN24-18H1A | ApooDr | 1.5 tons18,000 Btu/h · Non-ducted | 2.35 | 71% | 10.5 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 209157093 |
| 325AGN24-24H1BApooDr · AG Serieswith ductless indoor unit AGN24-24H1A | ApooDr | 2 tons24,000 Btu/h · Non-ducted | 2.22 | 75% | 8.5 | 21.0 | CEE 25CEE 26Xcel | 1 | 209157094 |