Skip to content

CEE 2026 Tier 1 (Split ASHP): 4,392 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
45.3%
Qualifying models
4,392
Qualifying certifications
87,792
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,806 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50123
1.50 to under 1.6087
1.60 to under 1.70115
1.70 to under 1.80716
1.80 to under 1.902,089
1.90 to under 2.001,247
2.00 to under 2.101,265
2.10 to under 2.20607
2.20 to under 2.30477
2.30 to under 2.40345
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,798 rated models · median 69%88% of rated models reach 50% (the lowest path) on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%366
40 to under 45%200
45 to under 50%286
50 to under 55%599
55 to under 60%783
60 to under 65%885
65 to under 70%799
70 to under 75%1,049
75 to under 80%488
80 to under 85%537
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%387
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF29,312 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3813
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3947
9.3 to under 9.5363
9.5 to under 9.8693
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,312 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.51,004
15.5 to under 16.0355
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5371
18.5 to under 19.0279
19.0 to under 19.5593
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER29,312 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,175
11.0 to under 11.5983
11.5 to under 12.01,096
12.0 to under 12.5918
12.5 to under 13.01,266
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons66.9% · 2,095 of 3,130
2 tons52.8% · 760 of 1,440
2.5–3 tons38.1% · 994 of 2,606
3.5–4.5 tons22.5% · 486 of 2,161
5 tons and up15.9% · 57 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted23.3%1,070 / 4,597
Non-ducted57.5%1,862 / 3,236
Ducted and non-ducted78.4%1,460 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric248 of 37366.5%
Midea230 of 40257.2%
Gree223 of 39556.5%
Carrier179 of 70125.5%
Lennox145 of 37139.1%
Rheem114 of 29139.2%
Hisense103 of 15964.8%
Daikin94 of 36725.6%
Trane81 of 30926.2%
Fujitsu62 of 16437.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 132 of 176
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
3276MSH-24HD-AMulti MFG · MSH Serieswith ductless indoor unit 24HWMS0-C-M-AMulti MFG2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26XcelES CC3214232437
3277MSU-24HD-B-HMulti MFG · Hi ULTRA HDwith ducted air handler 24MPHP0-M-B-HMulti MFG2 tons22,000 Btu/h · Ducted2.0077%9.016.5CEE 25CEE 26Xcel1207104304
3278MSU-36HD-B-HMulti MFG · Hi ULTRA HDwith ducted air handler 36MPHP0-M-B-HMulti MFG3 tons34,000 Btu/h · Ducted2.0576%9.518.0CEE 25CEE 26Xcel1207104305
3279MSU-48HD-B-HMulti MFG · Hi ULTRA HDwith ducted air handler 48MPHP0-M-B-HMulti MFG4 tons48,000 Btu/h · Ducted1.9070%8.517.5CEE 25CEE 26Xcel1207104306
3280MIT12H2G31(O)MULTIZONEwith ductless indoor unit MIT12H2G31(I)MULTIZONE1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel19850218
3281MIT18H2G31(O)MULTIZONEwith ductless indoor unit MIT18H2G31(I)MULTIZONE1.5 tons18,000 Btu/h · Non-ducted1.8066%8.622.5CEE 25CEE 2619850219
3282NDHAM-28-ONAPOLEON · NDH seriesNAPOLEON2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%9.822.6CEE 25CEE 26XcelES CC3207683238
3283NDHAM-36-ONAPOLEON · NDH seriesNAPOLEON3 tons36,000 Btu/h · Non-ducted and mixed (multi-zone)1.9097%9.720.0CEE 25CEE 26XcelES CC2207683241
3284NDHAS22-12-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS22-12-INAPOLEON1 ton12,000 Btu/h · Non-ducted2.2574%10.823.1CEE 25CEE 26XcelES CC1207683230
3285NDHAS22-18-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS22-18-INAPOLEON1.5 tons18,000 Btu/h · Non-ducted2.3571%10.524.0CEE 25CEE 26XcelES CC1207683231
3286NDHAS22-24-ONAPOLEON · NDHA Serieswith ductless indoor unit NDHAS22-24-INAPOLEON2 tons24,000 Btu/h · Non-ducted2.2275%8.521.0CEE 25CEE 26Xcel1207683232
3287NDHAS26-09-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS26-09-INAPOLEON1 ton9,000 Btu/h · Non-ducted1.9788%11.528.1CEE 25CEE 26XcelES CC1207683233
3288NDHAS26-12-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS26-12-INAPOLEON1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC1207683234
3289NDHAS26-18-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS26-18-INAPOLEON1.5 tons18,000 Btu/h · Non-ducted1.80100%11.321.5CEE 25CEE 26XcelES CC1207683235
3290NDHAS26-24-ONAPOLEON · NDHA Serieswith ductless indoor unit NDHAS26-24-INAPOLEON2 tons24,000 Btu/h · Non-ducted2.2186%11.421.5CEE 25CEE 26XcelES CC1207683236
3291NDHBS20-12-ONAPOLEONwith ductless indoor unit NDHBS20-12-INAPOLEON1 ton12,000 Btu/h · Non-ducted1.7967%9.221.4CEE 25CEE 261207683228
3292NDHBS20-18-ONAPOLEONwith ductless indoor unit NDHBS20-18-INAPOLEON1.5 tons18,000 Btu/h · Non-ducted2.0762%8.719.5CEE 25CEE 261207683229
3293NH25-18H-ONAPOLEON · NH Serieswith ductless indoor unit NH25-24F-INAPOLEON2 tons21,600 Btu/h · Non-ducted2.07100%10.418.9CEE 25CEE 26XcelES CC2206597272
3294NH25-24H-ONAPOLEON · NH Serieswith ductless indoor unit NH25-24F-INAPOLEON2 tons21,600 Btu/h · Non-ducted2.07100%10.418.9CEE 25CEE 26XcelES CC1206598613
3295NS18HV24A36NAPOLEON · WSE Serieswith ducted air handler NPFX24ANAPOLEON2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26XcelES CC2207335552
3296NS18HV48A60NAPOLEONwith ducted air handler NPFX48ANAPOLEON4 tons48,000 Btu/h · Ducted1.8081%9.017.0CEE 25CEE 26Xcel2207335554
3297WSEHV2436RA1-NNAPOLEONwith indoor coil C(A,C,D,E)36A34+TDR and furnace WPV080T3AANAPOLEON3 tons34,400 Btu/h · Ducted2.2270%8.016.7CEE 25CEE 26XcelES CC34212621414
3298WSEHV4860RA1-NNAPOLEONwith indoor coil C(A,C,D,E)48D44+TDR and furnace WPV070T4BANAPOLEON4 tons46,000 Btu/h · Ducted2.5566%8.517.0CEE 25CEE 26XcelES CC37212621418
3299MOBMH180CNG Trade · MOBMH seriesNG Trade1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.221.0CEE 25CEE 26XcelES CC3213307862
3300MOBMH270CNG Trade · MOB seriesNG Trade2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3213307865

Explore qualifying models by COP at 5°F