CEE 2026 Tier 1 (Split ASHP): 4,502 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
45.8%
Qualifying models
4,502
Qualifying certifications
88,244
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%88% of rated models reach 50% (the lowest path) on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons67.5% · 2,160 of 3,201
2 tons53.4% · 777 of 1,454
2.5 to 3 tons38.3% · 1,009 of 2,633
3.5 to 4.5 tons22.9% · 497 of 2,174
5 tons and up16.3% · 59 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted23.2%1,070 / 4,608
Non-ducted58.7%1,946 / 3,317
Ducted and non-ducted78.3%1,486 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric255 of 40063.8%
Midea234 of 40857.4%
Gree231 of 40357.3%
Carrier179 of 70125.5%
Lennox145 of 37538.7%
Hisense115 of 16071.9%
Rheem114 of 29139.2%
Daikin94 of 37125.3%
Trane81 of 30926.2%
Fujitsu62 of 16437.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 137 of 181
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
3401WHU18SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHU18CTA21SNortek Global HVAC1.5 tons18,000 Btu/h · Ducted and non-ducted2.3673%10.020.5CEE 25CEE 26Xcel2207237537
3402WHU24SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHU24CTA21SNortek Global HVAC2 tons24,000 Btu/h · Ducted and non-ducted2.2079%10.018.5CEE 25CEE 26Xcel2207237538
3403WHU36SZA21SWESTINGHOUSEwith ductless indoor unit WHU36CTA21SNortek Global HVAC3 tons36,000 Btu/h · Ducted and non-ducted2.2874%9.818.0CEE 25CEE 26Xcel2207237539
3404WHZ09SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHZ09WMA21SNortek Global HVAC1 ton9,000 Btu/h · Non-ducted2.0589%10.527.5CEE 25CEE 26XcelES CC1207337194
3405WHZ12SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHZ12WMA21SNortek Global HVAC1 ton12,000 Btu/h · Non-ducted1.9581%9.823.5CEE 25CEE 26XcelES CC1207337195
3406TSC-NCC-12HA1/I3XI22NORTHCO CLIMAT.CAwith ductless indoor unit TSC-NCC-12HA1/I3XI22NORTHCO CLIMAT.CA1 ton12,000 Btu/h · Non-ducted1.8073%9.022.0CEE 25CEE 26Xcel1214311072
3407TSC-NCC-18HA2/I3XI21NORTHCO CLIMAT.CAwith ductless indoor unit TSC-NCC-18HA2/I3XI21NORTHCO CLIMAT.CA1.5 tons18,000 Btu/h · Non-ducted1.8066%9.022.0CEE 25CEE 261214311073
3408OHP-12-22-23-ANORTON AIR CONDITIONERS · OHP Serieswith ductless indoor unit DHP-12-12-U-ANORTON AIR CONDITIONERS1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC1217500257
3409LEA09SZ15SK-ONOVAIR · LEA SERIESwith ductless indoor unit LEA0915SK-INOVAIR1 ton9,000 Btu/h · Non-ducted2.1670%9.121.5CEE 25CEE 26XcelES CC1207526949
3410LEA09SZ25SK-ONOVAIR · LEA SERIESwith ductless indoor unit LEA09UUSK-INOVAIR1 ton9,000 Btu/h · Non-ducted2.2286%11.624.0CEE 25CEE 26XcelES CC3207526946
3411LEA09SZ35SK-ONOVAIR · LEA SERIESwith ductless indoor unit 2LEA09UUSK-INOVAIR1 ton9,000 Btu/h · Non-ducted1.9788%11.528.1CEE 25CEE 26XcelES CC2211709682
3412LEA12SZ25SK-ONOVAIR · LEA SERIESwith ductless indoor unit 2LEA12UUSK-INOVAIR1 ton12,000 Btu/h · Non-ducted2.3967%10.724.6CEE 25CEE 26XcelES CC2211709678
3413LEA12SZ35SK-ONOVAIR · LEA SERIESwith ductless indoor unit LEA12UUSK-INOVAIR1 ton12,000 Btu/h · Non-ducted1.8992%10.523.1CEE 25CEE 26XcelES CC2207539337
3414LEA18-EVOX-30-ONOVAIR · LEA Serieswith ducted air handler LEA-18/24-ACOIL-410ANOVAIR1.5 tons18,000 Btu/h · Ducted2.2079%9.516.1CEE 25CEE 26XcelES CC2214867643
3415LEA18MZ-2P-25SK-ONOVAIR · LEA SERIESNOVAIR1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.221.0CEE 25CEE 26XcelES CC3207641276
3416LEA18SZ15SK-ONOVAIR · LEA SERIESwith ductless indoor unit LEA1815SK-INOVAIR1.5 tons18,000 Btu/h · Non-ducted2.0762%8.719.5CEE 25CEE 261207526952
3417LEA18SZ25SK-ONOVAIR · LEA SERIESwith ductless indoor unit LEA18UUSK-INOVAIR1.5 tons18,000 Btu/h · Non-ducted2.3571%10.524.0CEE 25CEE 26XcelES CC2207526951
3418LEA18SZ35SK-ONOVAIR · LEA SERIESwith ductless indoor unit LEA18UUSK-INOVAIR1.5 tons18,000 Btu/h · Non-ducted1.8996%10.622.0CEE 25CEE 26XcelES CC2207526948
3419LEA20MZ-2P-35SK-ONOVAIR · LEA SERIESNOVAIR1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.5CEE 25CEE 26XcelES CC3209416884
3420LEA20MZ-2P-35SK-O*NOVAIR · LEA SERIESNOVAIR1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.822.0CEE 25CEE 26XcelES CC3212920679
3421LEA24-EVOX-30-ONOVAIR · LEA Serieswith ducted air handler LEA-18/24-ACOIL-410ANOVAIR2 tons24,000 Btu/h · Ducted1.9580%9.516.5CEE 25CEE 26XcelES CC2214867641
3422LEA24SZ25SK-ONOVAIR · LEA SERIESwith ductless indoor unit 2LEA24UUSK-INOVAIR2 tons24,000 Btu/h · Non-ducted2.0470%10.022.0CEE 25CEE 26Xcel1211709680
3423LEA24SZ35SK-ONOVAIR · LEA SERIESwith ductless indoor unit 2LEA24UUSK-INOVAIR2 tons24,000 Btu/h · Non-ducted2.2186%11.421.5CEE 25CEE 26XcelES CC2211709685
3424LEA27MZ-3P-25SK-ONOVAIR · LEA SERIESNOVAIR2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.221.0CEE 25CEE 26Xcel3207641273
3425LEA28MZ-3P-35SK-ONOVAIR · LEA SERIESNOVAIR2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%9.822.6CEE 25CEE 26XcelES CC3209416881

Explore qualifying models by COP at 5°F