Skip to content

CEE 2026 Tier 1 (Split ASHP): 4,390 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
45.5%
Qualifying models
4,390
Qualifying certifications
87,783
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%88% of rated models reach 50% (the lowest path) on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF29,263 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8691
6.8 to under 7.067
7.0 to under 7.3239
7.3 to under 7.565
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3814
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3946
9.3 to under 9.5361
9.5 to under 9.8692
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,263 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5987
15.5 to under 16.0347
16.0 to under 16.5716
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER29,263 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,156
11.0 to under 11.5964
11.5 to under 12.01,096
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons67% · 2,096 of 3,130
2 tons52.9% · 760 of 1,437
2.5–3 tons38.3% · 992 of 2,588
3.5–4.5 tons22.7% · 485 of 2,136
5 tons and up16.3% · 57 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted23.6%1,073 / 4,549
Non-ducted57.5%1,862 / 3,236
Ducted and non-ducted78.4%1,455 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric248 of 37366.5%
Midea230 of 40257.2%
Gree223 of 39556.5%
Carrier179 of 70125.5%
Lennox141 of 31345%
Rheem114 of 29139.2%
Hisense103 of 15964.8%
Daikin94 of 36725.6%
Trane81 of 30926.2%
Fujitsu62 of 16437.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 172 of 176
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
4276YSMO-27HFN1YONANYONAN2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3212615072
4277YSMO-30HRN1YONANYONAN2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3207691833
4278YSMO-48HFN1YONANYONAN4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%9.521.1CEE 25CEE 263212615078
4279YSMO-48HRN1YONANYONAN4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%9.521.1CEE 25CEE 263207691830
4280CVAHP036B21S*Coleman · Mini VRFYork3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8173%10.822.2CEE 25CEE 26Xcel3203994971
4281CVAHP048B21S*Coleman · Mini VRFYork4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9559%10.018.1CEE 25CEE 263203994980
4282DHP30CSB22SYorkwith ductless indoor unit DHP30NWB22SYork2.5 tons30,000 Btu/h · Non-ducted1.8177%8.520.0CEE 25CEE 26Xcel4209818478
4283DHP36CSB22SYorkwith ductless indoor unit DHP36NWB22SYork3 tons33,600 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel4209818483
4284DHS18CMB22SYorkYork1.5 tons18,000 Btu/h · Ducted and non-ducted1.81104%10.020.0CEE 25CEE 26Xcel8207616532
4285DHS24CMB22SYorkYork2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80115%10.020.0CEE 25CEE 26Xcel12207616534
4286HC19B4821COLEMANwith indoor coil H,YG84960 and furnace CP9C080C16MP13York4 tons45,500 Btu/h · Ducted2.3460%8.116.0CEE 25CEE 26100213362196
4287HL19B4821LUXAIRE · ACCLIMATEwith indoor coil XAHC60HBCN1 and furnace TM8Y100C16MP11York4 tons45,500 Btu/h · Ducted2.3253%8.117.0CEE 25CEE 26187209375041
4288HMH72B341LUXAIREwith indoor coil D(A,C,E)36A34+TDR and furnace LP9C120D20MP13York2.5 tons31,200 Btu/h · Ducted3.2178%8.516.8CEE 25CEE 26CEE AdvXcelDOEES CC13,786214092242
4289RHP15024B21GUARDIANwith indoor coil D(A,C,E)36B34+TDR and furnace RL18100B12MPS1York2 tons22,400 Btu/h · Ducted2.7864%8.216.0CEE 25CEE 26121213281876
4290RHP15030B21GUARDIANwith ducted air handler AEL+D(A,C,E)36A44+TDRYork2.5 tons27,600 Btu/h · Ducted3.1375%8.015.0CEE 25CEE 26Xcel107212912446
4291RHP15036B21GUARDIANwith ducted air handler AE(D,N,U)+CM36B34+TDRYork3 tons33,000 Btu/h · Ducted3.0474%7.815.2CEE 25CEE 26XcelES CC111214638551
4292RHP15042B21GUARDIANwith ducted air handler AEL+D(A,C,E)48B44+TDRYork3.5 tons40,000 Btu/h · Ducted3.3572%7.616.1CEE 25CEE 26Xcel115212912448
4293RHP15048B21GUARDIANwith ducted air handler L(E,G)M60A4York4 tons45,000 Btu/h · Ducted3.7083%8.115.5CEE 25CEE 26Xcel117213612208
4294RHP15060B21GUARDIANwith ducted air handler L(E,G)M60A4York4.5 tons54,500 Btu/h · Ducted3.0169%8.215.5CEE 25CEE 26Xcel79213612210
4295THF2B24T21COLEMANwith ducted air handler L(E,G)M36A4York2 tons21,600 Btu/h · Ducted2.7357%8.215.0CEE 25CEE 26Xcel2,272213352198
4296THF2B30T21LUXAIREwith ducted air handler LEM324York2.5 tons28,000 Btu/h · Ducted3.1675%7.515.2CEE 25CEE 26Xcel2,672211599485
4297THF2B36T21LUXAIREwith ducted air handler AE(D,N,U)+CM48C34+TDRYork3 tons34,200 Btu/h · Ducted3.1674%8.115.5CEE 25CEE 26XcelES CC2,735214606335
4298THF2B42T21LUXAIREwith ducted air handler LEM48C4York3.5 tons39,000 Btu/h · Ducted3.3372%8.116.0CEE 25CEE 26Xcel2,774211599529
4299THF2B48T21CHAMPION HEATING AND COOLINGwith ducted air handler L(E,G)M60A4York4 tons45,000 Btu/h · Ducted3.7083%8.115.5CEE 25CEE 26Xcel3,827213612243
4300THF2B60T21CHAMPION HEATING AND COOLINGwith ducted air handler L(E,G)M60A4York4.5 tons54,500 Btu/h · Ducted3.0169%8.215.5CEE 25CEE 26Xcel1,980213612245

Explore qualifying models by COP at 5°F