Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026 Tier 1 (Split ASHP): 4,390 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 45.5%
- Qualifying models
- 4,390
- Qualifying certifications
- 87,783
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,085 |
| 1.90 to under 2.00 | 1,249 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 470 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 531 |
| 85 to under 90% | 415 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 691 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 239 |
| 7.3 to under 7.5 | 65 |
| 7.5 to under 7.8 | 1,051 |
| 7.8 to under 8.0 | 534 |
| 8.0 to under 8.3 | 814 |
| 8.3 to under 8.5 | 123 |
| 8.5 to under 8.8 | 1,436 |
| 8.8 to under 9.0 | 268 |
| 9.0 to under 9.3 | 946 |
| 9.3 to under 9.5 | 361 |
| 9.5 to under 9.8 | 692 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 623 |
| 10.3 to under 10.5 | 171 |
| 10.5 to under 10.8 | 303 |
| 10.8 to under 11.0 | 79 |
| 11.0 to under 11.3 | 175 |
| 11.3 to under 11.5 | 85 |
| 11.5 to under 11.8 | 116 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 658 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 987 |
| 15.5 to under 16.0 | 347 |
| 16.0 to under 16.5 | 716 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 370 |
| 18.5 to under 19.0 | 277 |
| 19.0 to under 19.5 | 590 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 388 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,156 |
| 11.0 to under 11.5 | 964 |
| 11.5 to under 12.0 | 1,096 |
| 12.0 to under 12.5 | 908 |
| 12.5 to under 13.0 | 1,265 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons67% · 2,096 of 3,130
- 2 tons52.9% · 760 of 1,437
- 2.5–3 tons38.3% · 992 of 2,588
- 3.5–4.5 tons22.7% · 485 of 2,136
- 5 tons and up16.3% · 57 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 67% · 2,096 of 3,130 |
| 2 tons | 52.9% · 760 of 1,437 |
| 2.5–3 tons | 38.3% · 992 of 2,588 |
| 3.5–4.5 tons | 22.7% · 485 of 2,136 |
| 5 tons and up | 16.3% · 57 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 23.6% | 1,073 / 4,549 |
| Non-ducted | 57.5% | 1,862 / 3,236 |
| Ducted and non-ducted | 78.4% | 1,455 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Mitsubishi Electric | 248 of 373 | 66.5% |
| Midea | 230 of 402 | 57.2% |
| Gree | 223 of 395 | 56.5% |
| Carrier | 179 of 701 | 25.5% |
| Lennox | 141 of 313 | 45% |
| Rheem | 114 of 291 | 39.2% |
| Hisense | 103 of 159 | 64.8% |
| Daikin | 94 of 367 | 25.6% |
| Trane | 81 of 309 | 26.2% |
| Fujitsu | 62 of 164 | 37.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 126HVH825GKA3*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716A | ACIQ | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 360 | 213062931 |
| 127HVH837GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120A | ACIQ | 2.5 tons31,800 Btu/h · Ducted | 2.10 | 83% | 7.5 | 17.0 | CEE 25CEE 26Xcel | 223 | 213062483 |
| 128HVH837GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122A | ACIQ | 3 tons33,200 Btu/h · Ducted | 2.02 | 131% | 8.5 | 18.0 | CEE 25CEE 26Xcel | 240 | 213067169 |
| 129HVH837GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X61L24A and furnace OMV154L20A | ACIQ | 3 tons33,000 Btu/h · Ducted | 2.12 | 60% | 8.1 | 17.0 | CEE 25CEE 26 | 74 | 213066907 |
| 130N4H7T60*K*AAA*ACIQ · 2-STAGE 17 SEER HPwith indoor coil EHD4X60AAL and furnace *80MSU0802120A | ACIQ | 4.5 tons54,500 Btu/h · Ducted | 2.28 | 51% | 7.5 | 14.5 | CEE 25CEE 26 | 96 | 213073843 |
| 131SC-09ZPL-HP230ACIQwith ductless indoor unit SC-09WPL-HP230 | ACIQ | 1 ton9,000 Btu/h · Non-ducted | 1.91 | 144% | 11.0 | 27.0 | CEE 25CEE 26Xcel | 1 | 208650735 |
| 132SC-12ZGLD-HP230ACIQwith ductless indoor unit SC-12WGLD-HP230 | ACIQ | 1 ton12,000 Btu/h · Non-ducted | 1.84 | 75% | 9.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 208650739 |
| 133SC-12ZPL-HP230ACIQwith ductless indoor unit SC-12WPL-HP230 | ACIQ | 1 ton12,000 Btu/h · Non-ducted | 1.91 | 98% | 8.5 | 24.0 | CEE 25CEE 26Xcel | 1 | 208650736 |
| 134SC-18Z-HH-M2ACIQ | ACIQ | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.81 | 104% | 10.0 | 20.0 | CEE 25CEE 26Xcel | 3 | 208674918 |
| 135SC-18ZPL-HP230ACIQwith ductless indoor unit SC-18WPL-HP230 | ACIQ | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 111% | 10.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 208650737 |
| 136SC-2436-HPACIQ · Ultra Heat Unitary Condensing Unitwith ducted air handler SC-24-AH | ACIQ | 2 tons24,000 Btu/h · Ducted | 1.80 | 92% | 9.0 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 211717285 |
| 137SC-27Z-HH-M3ACIQ | ACIQ | 2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 115% | 10.0 | 20.0 | CEE 25CEE 26Xcel | 3 | 208674921 |
| 138SC-27Z-HH-M4BACIQ · Extreme Heat | ACIQ | 2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 215742358 |
| 139SC-30ZGLD-HP230BACIQwith ductless indoor unit SC-30WGLD-HP230B | ACIQ | 2.5 tons30,000 Btu/h · Non-ducted | 1.81 | 77% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 211580579 |
| 140SC-36ZGLD-HP230BACIQwith ductless indoor unit SC-36WGLD-HP230B | ACIQ | 3 tons33,600 Btu/h · Non-ducted | 1.85 | 71% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 211580583 |
| 141SC-4860-HPACIQ · Ultra Heat Unitary Condensing Unitwith ducted air handler SC-48-AH | ACIQ | 4 tons48,000 Btu/h · Ducted | 1.80 | 81% | 9.0 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 211717287 |
| 142UB1MSHQCO09ACiQ · Hi MULTI Xtremewith ductless indoor unit UB1MSHQCW09 | ACIQ | 1 ton9,000 Btu/h · Non-ducted | 2.09 | 81% | 9.0 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 208287562 |
| 143UB1MSHQCO12ACiQ · HiULTRAwith ductless indoor unit UB1MSHQCW12 | ACIQ | 1 ton12,000 Btu/h · Non-ducted | 1.86 | 81% | 9.5 | 21.7 | CEE 25CEE 26Xcel | 1 | 208287565 |
| 144UB1MSHQCO18ACiQ · Hi MULTI Xtremewith ductless indoor unit UB1MSHQCW18 | ACIQ | 1.5 tons18,000 Btu/h · Non-ducted | 1.87 | 77% | 8.6 | 22.5 | CEE 25CEE 26XcelES CC | 1 | 208287567 |
| 145UB1MSHQCO24ACiQ · Hi MULTI Xtremewith ductless indoor unit UB1MSHQCW24 | ACIQ | 2 tons23,000 Btu/h · Non-ducted | 2.13 | 89% | 8.6 | 20.5 | CEE 25CEE 26XcelES CC | 1 | 208287568 |
| 1464HP18V36PADPwith indoor coil H,A,DE36936 and furnace 96G2UH090CV12 | ADP | 3 tons34,600 Btu/h · Ducted | 2.22 | 58% | 8.5 | 18.0 | CEE 25CEE 26 | 1 | 207092127 |
| 1474TXD2036A10NU**ADPwith ducted air handler F,PE*E32930 | ADP | 2 tons23,000 Btu/h · Ducted | 2.10 | 107% | 8.9 | 16.0 | CEE 25CEE 26CEE AdvXcelDOE | 15 | 212396546 |
| 1484TXD2060A10NU**ADPwith ducted air handler F,PE*CC7948 | ADP | 4 tons48,000 Btu/h · Ducted | 1.82 | 90% | 9.0 | 17.0 | CEE 25CEE 26Xcel | 19 | 212396557 |
| 149AUWR-36U3SA2ADPwith ducted air handler F,PE*TT3937 | ADP | 3 tons34,000 Btu/h · Ducted | 2.05 | 77% | 9.5 | 17.0 | CEE 25CEE 26Xcel | 1 | 215350408 |
| 150BOVA-36HDN1-M20GADPwith indoor coil HE31930 and furnace BGH96M060B3A | ADP | 2 tons22,800 Btu/h · Ducted | 2.12 | 77% | 8.7 | 18.0 | CEE 25CEE 26Xcel | 11 | 212361441 |