CEE 2026 Tier 1 (Split ASHP): 4,502 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
45.8%
Qualifying models
4,502
Qualifying certifications
88,244
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%88% of rated models reach 50% (the lowest path) on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.671% of rated models reach 8 (the lowest path) on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.568% of rated models reach 16 on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.3At least 81% of rated models reach 9.8 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons67.5% · 2,160 of 3,201
2 tons53.4% · 777 of 1,454
2.5 to 3 tons38.3% · 1,009 of 2,633
3.5 to 4.5 tons22.9% · 497 of 2,174
5 tons and up16.3% · 59 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted23.2%1,070 / 4,608
Non-ducted58.7%1,946 / 3,317
Ducted and non-ducted78.3%1,486 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric255 of 40063.8%
Midea234 of 40857.4%
Gree231 of 40357.3%
Carrier179 of 70125.5%
Lennox145 of 37538.7%
Hisense115 of 16071.9%
Rheem114 of 29139.2%
Daikin94 of 37125.3%
Trane81 of 30926.2%
Fujitsu62 of 16437.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 85 of 181
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2101ACA-2504hykolitywith ductless indoor unit ACA-2503hykolity1 ton12,000 Btu/h · Non-ducted1.8070%8.519.0CEE 25CEE 26Xcel1214584768
2102ACA-2531hykolityhykolity1.5 tons18,000 Btu/h · Non-ducted1.8065%8.520.0CEE 25CEE 261217497281
2103ICAO09AJICONIC AIR SOLUTIONwith ductless indoor unit IFAH09IJICONIC AIR SOLUTION1 ton9,000 Btu/h · Non-ducted1.9266%9.021.5CEE 25CEE 261214389485
2104ICAO09AKICONIC AIR SOLUTIONwith ductless indoor unit IFAH09IKICONIC AIR SOLUTION1 ton9,000 Btu/h · Non-ducted1.9564%9.121.7CEE 25CEE 261214389487
2105ICLO18AKICONIC AIR SOLUTIONwith ducted air handler IFLA18IKICONIC AIR SOLUTION1.5 tons18,000 Btu/h · Ducted2.0061%8.817.0CEE 25CEE 262213412064
2106ICLO24AKICONIC AIR SOLUTIONwith ducted air handler IFLA24IKICONIC AIR SOLUTION2 tons24,000 Btu/h · Ducted2.1075%9.217.0CEE 25CEE 26Xcel2213412065
2107ICLZ18AKICONIC AIR SOLUTIONwith ducted air handler IFLA18IKICONIC AIR SOLUTION1.5 tons18,000 Btu/h · Ducted2.0498%9.318.0CEE 25CEE 26Xcel2213412074
2108ICLZ24AKICONIC AIR SOLUTIONwith ducted air handler IFLA24IKICONIC AIR SOLUTION2 tons24,000 Btu/h · Ducted1.91100%10.017.4CEE 25CEE 26Xcel2213412076
2109ICLZ30AKICONIC AIR SOLUTIONwith ducted air handler IFLV30IKICONIC AIR SOLUTION2.5 tons28,000 Btu/h · Ducted1.8289%8.818.2CEE 25CEE 26Xcel2213804893
2110ICLZ36AKICONIC AIR SOLUTIONwith ducted air handler IFLA36IKICONIC AIR SOLUTION3 tons36,000 Btu/h · Ducted1.9692%9.516.0CEE 25CEE 26Xcel2213412079
2111ICMO18BKICONIC AIR SOLUTIONICONIC AIR SOLUTION1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8674%10.221.0CEE 25CEE 26Xcel3214389500
2112ICMO24CKICONIC AIR SOLUTIONICONIC AIR SOLUTION2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3214389503
2113ICMO27CKICONIC AIR SOLUTIONICONIC AIR SOLUTION2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3214389506
2114ICMO30DKICONIC AIR SOLUTIONICONIC AIR SOLUTION2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9060%9.220.0CEE 25CEE 263216720872
2115ICMO48EKICONIC AIR SOLUTIONICONIC AIR SOLUTION4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%9.521.1CEE 25CEE 263216720876
2116ICMZ18BKICONIC AIR SOLUTIONICONIC AIR SOLUTION1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.5CEE 25CEE 26Xcel3214389521
2117ICMZ24CKICONIC AIR SOLUTIONICONIC AIR SOLUTION2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9075%9.721.3CEE 25CEE 26Xcel3214389526
2118ICMZ27CKICONIC AIR SOLUTIONICONIC AIR SOLUTION2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7690%9.822.6CEE 25CEE 26Xcel3214389527
2119ICMZ36DKICONIC AIR SOLUTIONICONIC AIR SOLUTION3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.90102%9.720.0CEE 25CEE 26Xcel3214389530
2120ICMZ48EKICONIC AIR SOLUTIONICONIC AIR SOLUTION4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9396%10.021.2CEE 25CEE 26Xcel3214389533
2121ICMZ60EKICONIC AIR SOLUTIONICONIC AIR SOLUTION4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.520.0CEE 25CEE 26Xcel3214389536
2122ICOO09AJICONIC AIR SOLUTIONwith ductless indoor unit IFOH09IJICONIC AIR SOLUTION1 ton9,000 Btu/h · Non-ducted2.0775%9.823.0CEE 25CEE 26Xcel1214389494
2123ICOO09AKICONIC AIR SOLUTIONwith ductless indoor unit IFOB06-09IKICONIC AIR SOLUTION1 ton9,000 Btu/h · Ducted and non-ducted2.3777%11.522.5CEE 25CEE 26Xcel5214640133
2124ICOO12AJICONIC AIR SOLUTIONwith ductless indoor unit IFOH12IJICONIC AIR SOLUTION1 ton12,000 Btu/h · Non-ducted2.0757%10.422.7CEE 25CEE 261214389495
2125ICOO12AKICONIC AIR SOLUTIONwith ductless indoor unit IFOC12IKICONIC AIR SOLUTION1 ton12,000 Btu/h · Ducted and non-ducted2.2867%10.022.7CEE 25CEE 26Xcel4214389545

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter