Both views use the same certified data. This device remembers your choice.
CEE 2026 Tier 1 (Split ASHP): 4,502 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 45.8%
- Qualifying models
- 4,502
- Qualifying certifications
- 88,244
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 124 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 118 |
| 1.70 to under 1.80 | 916 |
| 1.80 to under 1.90 | 2,176 |
| 1.90 to under 2.00 | 1,272 |
| 2.00 to under 2.10 | 1,285 |
| 2.10 to under 2.20 | 613 |
| 2.20 to under 2.30 | 484 |
| 2.30 to under 2.40 | 356 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 114 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.91 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 68 |
| 35 to under 40% | 378 |
| 40 to under 45% | 216 |
| 45 to under 50% | 320 |
| 50 to under 55% | 640 |
| 55 to under 60% | 790 |
| 60 to under 65% | 964 |
| 65 to under 70% | 885 |
| 70 to under 75% | 1,102 |
| 75 to under 80% | 505 |
| 80 to under 85% | 543 |
| 85 to under 90% | 414 |
| 90 to under 95% | 386 |
| 95 to under 100% | 274 |
| 100 to under 105% | 389 |
| 105 to under 110% | 73 |
| 110 to under 115% | 81 |
| 115 to under 120% | 28 |
| 120 to under 125% | 46 |
| 125 to under 130% | 12 |
| 130% and above | 32 |
| Baseline: median | 69% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 711 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 263 |
| 7.3 to under 7.5 | 67 |
| 7.5 to under 7.8 | 1,066 |
| 7.8 to under 8.0 | 513 |
| 8.0 to under 8.3 | 818 |
| 8.3 to under 8.5 | 125 |
| 8.5 to under 8.8 | 1,489 |
| 8.8 to under 9.0 | 275 |
| 9.0 to under 9.3 | 959 |
| 9.3 to under 9.5 | 371 |
| 9.5 to under 9.8 | 701 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 635 |
| 10.3 to under 10.5 | 173 |
| 10.5 to under 10.8 | 309 |
| 10.8 to under 11.0 | 81 |
| 11.0 to under 11.3 | 180 |
| 11.3 to under 11.5 | 86 |
| 11.5 to under 11.8 | 117 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 678 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 574 |
| 14.5 to under 15.0 | 326 |
| 15.0 to under 15.5 | 991 |
| 15.5 to under 16.0 | 357 |
| 16.0 to under 16.5 | 727 |
| 16.5 to under 17.0 | 303 |
| 17.0 to under 17.5 | 525 |
| 17.5 to under 18.0 | 332 |
| 18.0 to under 18.5 | 382 |
| 18.5 to under 19.0 | 284 |
| 19.0 to under 19.5 | 609 |
| 19.5 to under 20.0 | 172 |
| 20.0 to under 20.5 | 494 |
| 20.5 to under 21.0 | 260 |
| 21.0 to under 21.5 | 544 |
| 21.5 to under 22.0 | 330 |
| 22.0 to under 22.5 | 342 |
| 22.5 to under 23.0 | 183 |
| 23.0 to under 23.5 | 302 |
| 23.5 to under 24.0 | 168 |
| 24.0 to under 24.5 | 111 |
| 24.5 to under 25.0 | 56 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 55 |
| 26.0 to under 26.5 | 50 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 32 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 247 |
| 8.5 to under 9.0 | 608 |
| 9.0 to under 9.5 | 525 |
| 9.5 to under 10.0 | 392 |
| 10.0 to under 10.5 | 896 |
| 10.5 to under 11.0 | 1,192 |
| 11.0 to under 11.5 | 995 |
| 11.5 to under 12.0 | 1,102 |
| 12.0 to under 12.5 | 944 |
| 12.5 to under 13.0 | 1,269 |
| 13.0 to under 13.5 | 576 |
| 13.5 to under 14.0 | 231 |
| 14.0 to under 14.5 | 128 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 97 |
| 15.5 to under 16.0 | 78 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 34 |
| Baseline: median | 11.3 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons67.5% · 2,160 of 3,201
- 2 tons53.4% · 777 of 1,454
- 2.5 to 3 tons38.3% · 1,009 of 2,633
- 3.5 to 4.5 tons22.9% · 497 of 2,174
- 5 tons and up16.3% · 59 of 362
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 67.5% · 2,160 of 3,201 |
| 2 tons | 53.4% · 777 of 1,454 |
| 2.5 to 3 tons | 38.3% · 1,009 of 2,633 |
| 3.5 to 4.5 tons | 22.9% · 497 of 2,174 |
| 5 tons and up | 16.3% · 59 of 362 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 23.2% | 1,070 / 4,608 |
| Non-ducted | 58.7% | 1,946 / 3,317 |
| Ducted and non-ducted | 78.3% | 1,486 / 1,899 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Mitsubishi Electric | 255 of 400 | 63.8% |
| Midea | 234 of 408 | 57.4% |
| Gree | 231 of 403 | 57.3% |
| Carrier | 179 of 701 | 25.5% |
| Lennox | 145 of 375 | 38.7% |
| Hisense | 115 of 160 | 71.9% |
| Rheem | 114 of 291 | 39.2% |
| Daikin | 94 of 371 | 25.3% |
| Trane | 81 of 309 | 26.2% |
| Fujitsu | 62 of 164 | 37.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 2426A-DVH09SH-0COMFORT-AIRE · A-serieswith ductless indoor unit B-DVH09SH-0 | Lennox | 1 ton9,000 Btu/h · Non-ducted | 1.92 | 66% | 9.0 | 21.5 | CEE 25CEE 26 | 2 | 207691818 |
| 2427A-DVH09SH-1COMFORT-AIRE · A-serieswith ductless indoor unit B-DVH09SH-1 | Lennox | 1 ton9,000 Btu/h · Non-ducted | 1.95 | 64% | 9.1 | 21.7 | CEE 25CEE 26 | 2 | 207691820 |
| 2428A-KMH12SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-KMH12SU-1 | Lennox | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 83% | 9.5 | 23.6 | CEE 25CEE 26XcelES CC | 2 | 208141182 |
| 2429A-KMH18SU-1COMFORT-AIRE · A-serieswith ductless indoor unit B-KMH18SV-1 | Lennox | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 100% | 11.3 | 21.5 | CEE 25CEE 26XcelES CC | 2 | 208141188 |
| 2430A-KMH18SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-KMH18SU-1 | Lennox | 1.5 tons17,000 Btu/h · Non-ducted | 1.90 | 91% | 10.0 | 19.4 | CEE 25CEE 26Xcel | 2 | 208141183 |
| 2431A-KMH24SU-1COMFORT-AIRE · A-serieswith ductless indoor unit B-KMH24SV-1 | Lennox | 2 tons24,000 Btu/h · Non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26XcelES CC | 2 | 208141189 |
| 2432A-KMH24SU-1ACOMFORT-AIREwith ductless indoor unit B-KMH24SU-1A | Lennox | 2 tons21,600 Btu/h · Non-ducted | 1.89 | 100% | 10.4 | 18.9 | CEE 25CEE 26Xcel | 1 | 206061625 |
| 2433A-KMH24SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-KMH24SU-1 | Lennox | 2 tons21,600 Btu/h · Non-ducted | 2.07 | 100% | 10.4 | 18.9 | CEE 25CEE 26XcelES CC | 2 | 208141184 |
| 2434A-SVH09SB-0COMFORT-AIREwith ductless indoor unit B-SVH09SB-0 | Lennox | 1 ton9,000 Btu/h · Non-ducted | 1.88 | 65% | 9.0 | 17.0 | CEE 25CEE 26 | 2 | 205281495 |
| 2435A-SVH09SB-1COMFORT-AIRE · A-serieswith ductless indoor unit B-SVH09SB-1 | Lennox | 1 ton9,000 Btu/h · Non-ducted | 2.10 | 71% | 8.8 | 18.5 | CEE 25CEE 26XcelES CC | 2 | 205554605 |
| 2436A-VCD18SA-1COMFORT-AIRE · A serieswith ducted air handler MCD18/24B1A | Lennox | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26XcelES CC | 6 | 210568230 |
| 2437A-VCD24SA-1COMFORT-AIRE · A serieswith ducted air handler MCD18/24B1A | Lennox | 2 tons24,000 Btu/h · Ducted | 1.95 | 80% | 9.5 | 16.5 | CEE 25CEE 26XcelES CC | 6 | 210568229 |
| 2438A-VCD30SA-1COMFORT-AIRE · A serieswith ducted air handler MCD30/36C1A | Lennox | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26XcelES CC | 10 | 210568234 |
| 2439A-VCD36SA-1COMFORT-AIRE · A serieswith ducted air handler MCD30/36C1A | Lennox | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26XcelES CC | 10 | 210568236 |
| 2440A-VFH18DC-1COMFORT-AIRE · VFH-B/C | Lennox | 1.5 tons17,000 Btu/h · Non-ducted | 2.21 | 76% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 212508372 |
| 2441A-VFH24TC-1COMFORT-AIRE · VFH-B/C | Lennox | 2 tons23,200 Btu/h · Non-ducted | 2.10 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 212524533 |
| 2442A-VMH06SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-VMH06SV-1 | Lennox | 0.5 tons6,000 Btu/h · Non-ducted | 2.09 | 107% | 13.6 | 26.5 | CEE 25CEE 26XcelES CC | 2 | 207657385 |
| 2443A-VMH09SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-VMH09SV-1 | Lennox | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.97 | 88% | 11.5 | 28.1 | CEE 25CEE 26XcelES CC | 10 | 207657386 |
| 2444A-VMH12SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-VMH12FV-1 | Lennox | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 99% | 10.7 | 24.2 | CEE 25CEE 26XcelES CC | 14 | 213916260 |
| 2445A-VMH18DV-1COMFORT-AIRE · A-series | Lennox | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.83 | 100% | 9.3 | 19.0 | CEE 25CEE 26XcelES CC | 6 | 207657609 |
| 2446A-VMH18SU-1ACOMFORT-AIRE · A-serieswith ductless indoor unit B-VMH18SU-1B | Lennox | 1.5 tons17,000 Btu/h · Non-ducted | 1.90 | 91% | 10.0 | 19.4 | CEE 25CEE 26XcelES CC | 4 | 206913570 |
| 2447A-VMH18SU-1BCOMFORT-AIRE · A-serieswith ductless indoor unit B-VMH18SU-1B | Lennox | 1.5 tons17,000 Btu/h · Non-ducted | 1.90 | 91% | 10.0 | 19.4 | CEE 25CEE 26Xcel | 4 | 205747696 |
| 2448A-VMH18SV-1COMFORT-AIRE · A serieswith ducted air handler B-VMH18AV-1 | Lennox | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.00 | 89% | 9.6 | 17.6 | CEE 25CEE 26XcelES CC | 12 | 208136322 |
| 2449A-VMH24SU-1COMFORT-AIRE · A-serieswith ductless indoor unit B-VMH24SV-1 | Lennox | 2 tons24,000 Btu/h · Non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26XcelES CC | 4 | 208141178 |
| 2450A-VMH24SU-1ACOMFORT-AIRE · A-serieswith ductless indoor unit B-VMH24SU-1A | Lennox | 2 tons21,600 Btu/h · Non-ducted | 2.07 | 100% | 10.4 | 18.9 | CEE 25CEE 26XcelES CC | 4 | 206221394 |