CEE Advanced Tier (Split ASHP): 137 qualifying heat pumps

CEE’s cold-climate tier: full rated capacity and a COP of at least 2.1 at 5°F.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
1.4%
Qualifying models
137
Qualifying certifications
4,698
Paths
1

Criteria

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Advanced≥ 8.5≥ 2.1≥ 100%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE Advanced checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.9327% of rated models reach 2.1 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: CEE Adv. 2.12.10

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%8% of rated models reach 100% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: CEE Adv. 100%100%

Source: AHRI Directory · as of

HSPF29,263 rated models · median 8.661% of rated models reach 8.5 on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8691
6.8 to under 7.067
7.0 to under 7.3239
7.3 to under 7.565
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3814
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3946
9.3 to under 9.5361
9.5 to under 9.8692
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: CEE Adv. 8.58.5

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE Advanced, by size
Show the data as a table
Share of models meeting CEE Advanced, by size
GroupQualifying share
Up to 1.5 tons2.4% · 75 of 3,130
2 tons3.1% · 44 of 1,437
2.5–3 tons0.5% · 14 of 2,588
3.5–4.5 tons0.2% · 4 of 2,136
5 tons and up0% · 0 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted0.7%30 / 4,549
Non-ducted1.9%60 / 3,236
Ducted and non-ducted2.5%47 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric24 of 3736.4%
Rheem16 of 2915.5%
Carrier14 of 7012%
Midea11 of 4022.7%
Fujitsu10 of 1646.1%
LG7 of 789%
Daikin6 of 3671.6%
Samsung5 of 559.1%
Lennox3 of 3131%
KERR2 of 248.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.

This page is past the end of the list.

Explore qualifying models by COP at 5°F