CEE Advanced Tier (Split ASHP): 138 qualifying heat pumps
CEE’s cold-climate tier: full rated capacity and a COP of at least 2.1 at 5°F, with HSPF2 of at least 8.5.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 1.4%
- Qualifying models
- 138
- Qualifying certifications
- 4,700
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Advanced | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE Advanced checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 124 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 118 |
| 1.70 to under 1.80 | 916 |
| 1.80 to under 1.90 | 2,176 |
| 1.90 to under 2.00 | 1,272 |
| 2.00 to under 2.10 | 1,285 |
| 2.10 to under 2.20 | 613 |
| 2.20 to under 2.30 | 484 |
| 2.30 to under 2.40 | 356 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 114 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.91 |
| Baseline: CEE Adv. 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 68 |
| 35 to under 40% | 378 |
| 40 to under 45% | 216 |
| 45 to under 50% | 320 |
| 50 to under 55% | 640 |
| 55 to under 60% | 790 |
| 60 to under 65% | 964 |
| 65 to under 70% | 885 |
| 70 to under 75% | 1,102 |
| 75 to under 80% | 505 |
| 80 to under 85% | 543 |
| 85 to under 90% | 414 |
| 90 to under 95% | 386 |
| 95 to under 100% | 274 |
| 100 to under 105% | 389 |
| 105 to under 110% | 73 |
| 110 to under 115% | 81 |
| 115 to under 120% | 28 |
| 120 to under 125% | 46 |
| 125 to under 130% | 12 |
| 130% and above | 32 |
| Baseline: median | 69% |
| Baseline: CEE Adv. 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 711 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 263 |
| 7.3 to under 7.5 | 67 |
| 7.5 to under 7.8 | 1,066 |
| 7.8 to under 8.0 | 513 |
| 8.0 to under 8.3 | 818 |
| 8.3 to under 8.5 | 125 |
| 8.5 to under 8.8 | 1,489 |
| 8.8 to under 9.0 | 275 |
| 9.0 to under 9.3 | 959 |
| 9.3 to under 9.5 | 371 |
| 9.5 to under 9.8 | 701 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 635 |
| 10.3 to under 10.5 | 173 |
| 10.5 to under 10.8 | 309 |
| 10.8 to under 11.0 | 81 |
| 11.0 to under 11.3 | 180 |
| 11.3 to under 11.5 | 86 |
| 11.5 to under 11.8 | 117 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: CEE Adv. 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons2.4% · 78 of 3,201
- 2 tons3% · 43 of 1,454
- 2.5 to 3 tons0.5% · 14 of 2,633
- 3.5 to 4.5 tons0.1% · 3 of 2,174
- 5 tons and up0% · 0 of 362
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 2.4% · 78 of 3,201 |
| 2 tons | 3% · 43 of 1,454 |
| 2.5 to 3 tons | 0.5% · 14 of 2,633 |
| 3.5 to 4.5 tons | 0.1% · 3 of 2,174 |
| 5 tons and up | 0% · 0 of 362 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 0.6% | 29 / 4,608 |
| Non-ducted | 1.8% | 60 / 3,317 |
| Ducted and non-ducted | 2.6% | 49 / 1,899 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 101NTXSPH15B112A*Trane / Mitsubishi Electric · M-Serieswith ductless indoor unit NTXWPH15B112A | Mitsubishi Electric | 1 ton14,000 Btu/h · Non-ducted | 2.17 | 121% | 10.4 | 22.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 209832261 |
| 102NTXSPH18B112A*Trane / Mitsubishi Electric · M-Serieswith ductless indoor unit NTXWPH18B112A | Mitsubishi Electric | 1.5 tons17,200 Btu/h · Non-ducted | 2.15 | 121% | 10.7 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 209832262 |
| 103HO-SZ24-AB-QMitsutomo · HO Serieswith ductless indoor unit HF-UZ24-AB-Q | Mitsutomo | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 11.0 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 214056573 |
| 104DMA18HOS42230E4MOOVAIR · DM-serieswith ductless indoor unit DMA18HIW42230E4Not ranked: cold-weather ratings look inconsistent. | MOOVAIR | 1.5 tons18,000 Btu/h · Non-ducted | 2.89 | 120% | 11.0 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 207742501 |
| 105DMB18HOS42230E8BMOOVAIR · DMB serieswith ductless indoor unit DMB18HIW42230E8Not ranked: cold-weather ratings look inconsistent. | MOOVAIR | 1.5 tons18,000 Btu/h · Non-ducted | 2.89 | 120% | 11.0 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 213369384 |
| 106ACIQ-24ZPL-HP230BPolarWave · ACIQwith ductless indoor unit ACIQ-24W-HH-MB | PolarWave | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 212316074 |
| 107MLP18AZ36AJVCMAINLINEwith ducted air handler MLHMVZ6021SEACA | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 121% | 8.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 211641648 |
| 108RO1HFZ18AJ2HRHEEM · Classic Pluswith ductless indoor unit RIWHFZ18AJ2S | Rheem | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 88% | 10.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368088 |
| 109RO1HGZ09AJ1SRUUD · Classic Pluswith ductless indoor unit UIWHGZ09AJ1S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.15 | 128% | 13.4 | 33.1 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368099 |
| 110RO1HGZ12AJ1HRHEEM · Classic Pluswith ductless indoor unit RIWHGZ12AJ1S | Rheem | 1 ton12,000 Btu/h · Non-ducted | 2.16 | 104% | 12.7 | 29.4 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368104 |
| 111RO1HGZ12AJ1SRHEEM · Classic Pluswith ductless indoor unit RIWHGZ12AJ1S | Rheem | 1 ton12,000 Btu/h · Non-ducted | 2.32 | 104% | 12.9 | 29.4 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368102 |
| 112RO1HGZ15AJ1HRHEEM · Prestigewith ductless indoor unit RIWHGZ15AJ1S | Rheem | 1 ton14,500 Btu/h · Non-ducted | 2.34 | 97% | 12.7 | 25.3 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368108 |
| 113RO1HGZ15AJ1SRHEEM · Prestigewith ductless indoor unit RIWHGZ15AJ1S | Rheem | 1 ton14,500 Btu/h · Non-ducted | 2.52 | 97% | 12.8 | 25.3 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368106 |
| 114RO1HHZ09AJ8SRHEEM · Prestigewith ductless indoor unit RICHHZ09AJ8S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.22 | 84% | 11.8 | 23.5 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210824705 |
| 115RO1HHZ18AJ3SRUUDwith ductless indoor unit UIWHHZ18AJ3S | Rheem | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 103% | 10.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368119 |
| 116ROSH18AHXHJRHEEMwith ductless indoor unit RIWH18AVFJ | Rheem | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 88% | 10.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 10595377 |
| 117ROSH18VGSNRHEEMwith ductless indoor unit RICH18AXCJ | Rheem | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.32 | 86% | 10.5 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 4 | 202244046 |
| 118RP18AZ24AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ2421HEAAM and furnace R802V1004A17UHS | Rheem | 2 tons22,800 Btu/h · Ducted | 2.10 | 108% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 28 | 212609307 |
| 119RP18AZ36AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ6021SEAAM and furnace R802VA075317M | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 119% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 34 | 210589387 |
| 120SP18AZ24AJVCSURE · VANTIXwith indoor coil TCFZ2421HEAAM and furnace S802V0754A17UHN | Rheem | 2 tons22,800 Btu/h · Ducted | 2.10 | 108% | 8.5 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 27 | 212609310 |
| 121SP18AZ36AJVCSURE · VANTIXwith ducted air handler SHMVZ6021SEACA | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 121% | 8.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 30 | 210106714 |
| 122UP18AZ36AJVCRUUDwith indoor coil RCFZ6021SEAAM and furnace U802VA075317M | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 126% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 33 | 210589396 |
| 123SP18AZ24AJVCRUSSELL · VANTIXwith indoor coil TCFZ2421HEAAM and furnace S802V0504A17UHS | RUSSELL | 2 tons22,800 Btu/h · Ducted | 2.10 | 108% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 27 | 212609309 |
| 124SP18AZ36AJVCRUSSELL · VANTIXwith ducted air handler SHMVZ6021SEACA | RUSSELL | 3 tons34,200 Btu/h · Ducted | 2.20 | 121% | 8.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 30 | 210106900 |
| 125AC036BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC036BN4DCH | Samsung | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.17 | 103% | 8.8 | 20.5 | CEE 25CEE 26CEE AdvXcelDOE | 5 | 207462390 |