Skip to content

DOE Cold Climate Heat Pump Challenge: 138 qualifying heat pumps

Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.

Simple view, for homeowners: top picks by size and what each rating measures →

U.S. Department of EnergyData as of updated · sources

Share of models
1.4%
Qualifying models
138
Qualifying certifications
4,700
Paths
1

Criteria

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Challenge specification≥ 8.5≥ 2.1≥ 100%

Source: U.S. Department of Energy

Where the thresholds fall

Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.9126% of rated models reach 2.1 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: DOE CCHP 2.12.10

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%8% of rated models reach 100% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: DOE CCHP 100%100%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.661% of rated models reach 8.5 on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: DOE CCHP 8.58.5

Source: AHRI Directory · as of

Qualification by size

Share of models meeting DOE CCHP, by size
Show the data as a table
Share of models meeting DOE CCHP, by size
GroupQualifying share
Up to 1.5 tons2.4% · 78 of 3,201
2 tons3% · 43 of 1,454
2.5 to 3 tons0.5% · 14 of 2,633
3.5 to 4.5 tons0.1% · 3 of 2,174
5 tons and up0% · 0 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted0.6%29 / 4,608
Non-ducted1.8%60 / 3,317
Ducted and non-ducted2.6%49 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric24 of 4006%
Rheem16 of 2915.5%
Carrier14 of 7012%
Midea11 of 4082.7%
Fujitsu10 of 1646.1%
LG6 of 787.7%
Daikin6 of 3711.6%
Samsung5 of 559.1%
HAIER4 of 537.5%
Lennox3 of 3750.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting DOE Cold Climate Heat Pump Challenge, page 2 of 6
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
26MSH183G26MCAAGOODMAN · MSH Serieswith ductless indoor unit MSH183G26AXAANot ranked: cold-weather ratings look inconsistent.Daikin1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC1214438121
27RXL09WMVJU*DAIKINwith ductless indoor unit FVXS09WVJUDaikin1 ton9,000 Btu/h · Non-ducted2.10100%9.719.5CEE 25CEE 26CEE AdvXcelDOE4212521709
28RXL12WMVJU*DAIKINwith ductless indoor unit FTX12WMVJUDaikin1 ton10,600 Btu/h · Ducted and non-ducted2.26107%10.019.5CEE 25CEE 26CEE AdvXcelDOE5212506076
29RXL15WMVJU*DAIKINwith ductless indoor unit FVXS15WVJUDaikin1.5 tons15,000 Btu/h · Non-ducted2.40100%9.319.5CEE 25CEE 26CEE AdvXcelDOE4212506084
30RZQ36TBVJU*DAIKINwith ducted air handler FXMQ36TBVJUDaikin3 tons35,000 Btu/h · Ducted and non-ducted2.10100%8.816.9CEE 25CEE 26CEE AdvXcelDOE5216521352
31DIRM-24HXPRO28-1ZDIRECT AIR · DIRM serieswith ductless indoor unit DIRM-24HP-WMDIRECT AIR2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC4207743727
32ACIQ-24ZPL-HP230BDIYCOOL · ACIQwith ductless indoor unit ACIQ-24W-HH-MBDIYCOOL2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC5207825553
33DRA1H24S1ADurastar · DRA1with ductless indoor unit DRAF24F1ADurastar2 tons24,000 Btu/h · Ducted and non-ducted2.10100%11.020.5CEE 25CEE 26CEE AdvXcelDOEES CC5210568120
34MOX430U-18HFN1-MECO-AIR · MOX Serieswith ducted air handler MVBE-18HWFN1-MM3EECO-AIR1.5 tons18,000 Btu/h · Ducted2.3099%10.819.3CEE 25CEE 26CEE AdvXcelDOEES CC4213307908
35FRP18AZ24AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHUFriedrich2 tons22,800 Btu/h · Ducted2.10108%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC21213829710
36FRP18AZ36AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHUFriedrich3 tons34,200 Btu/h · Ducted2.20121%8.519.0CEE 25CEE 26CEE AdvXcelDOEES CC23213829722
37AOU18RGLXFUJITSU · H-Serieswith ductless indoor unit AUU18RGLXFujitsu1.5 tons18,000 Btu/h · Ducted and non-ducted2.32101%10.522.0CEE 25CEE 26CEE AdvXcelDOE2202195106
38AOU18RLXFWHFUJITSU · H-Serieswith ductless indoor unit ASU18RLFFujitsu1.5 tons18,000 Btu/h · Non-ducted2.18106%10.020.0CEE 25CEE 26CEE AdvXcelDOEES CC18779045
39AOUG12LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZASFujitsu1 ton12,000 Btu/h · Non-ducted2.16138%12.729.4CEE 25CEE 26CEE AdvXcelDOEES CC2204740069
40AOUG12LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZASFujitsu1 ton12,000 Btu/h · Non-ducted2.32138%12.929.4CEE 25CEE 26CEE AdvXcelDOEES CC2204740068
41AOUG15LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZASFujitsu1 ton14,500 Btu/h · Non-ducted2.12145%12.725.3CEE 25CEE 26CEE AdvXcelDOEES CC2204740071
42AOUG15LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZASFujitsu1 ton14,500 Btu/h · Non-ducted2.24145%12.825.3CEE 25CEE 26CEE AdvXcelDOEES CC2204740070
43AOUH09LMAS1FUJITSU · H-Serieswith ductless indoor unit ASUH09LMASFujitsu1 ton9,000 Btu/h · Non-ducted2.35113%12.626.5CEE 25CEE 26CEE AdvXcelDOEES CC1207615688
44AOUH09LUAS1FUJITSU · H-Serieswith ductless indoor unit ACUH09LUAS1Fujitsu1 ton9,000 Btu/h · Ducted and non-ducted2.23112%11.823.5CEE 25CEE 26CEE AdvXcelDOEES CC2206579743
45AOUH18LPAS1FUJITSUwith ductless indoor unit ASUH18LPASFujitsu1.5 tons18,000 Btu/h · Non-ducted2.14101%10.520.0CEE 25CEE 26CEE AdvXcelDOE1207131734
46FOP1836MJAZCAFUJITSU · F Serieswith indoor coil FCCA6021SZEA and furnace FF75173LT80XFujitsu3 tons34,200 Btu/h · Ducted2.20119%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC14210868911
47ASH112URDE**GE Appliances · Endurewith ductless indoor unit ASYW12URDEGE Appliances1 ton12,000 Btu/h · Ducted and non-ducted2.31117%12.527.5CEE 25CEE 26CEE AdvXcelDOEES CC4212409457
48ASH118URDE**GE Appliances · Endurewith ductless indoor unit ASYW18URDEGE Appliances1.5 tons17,800 Btu/h · Ducted and non-ducted2.34100%12.023.0CEE 25CEE 26CEE AdvXcelDOEES CC4212409458
491U09EH2VHE*HAIER · Arcticwith ductless indoor unit AW09EH2VHDHAIER1 ton9,000 Btu/h · Non-ducted2.11120%14.030.0CEE 25CEE 26CEE AdvXcelDOE1206445819
501U12EH2HE**HAIER · Arcticwith ductless indoor unit AW12EH2HEHAIER1 ton12,000 Btu/h · Ducted and non-ducted2.31117%12.527.5CEE 25CEE 26CEE AdvXcelDOEES CC4212409448

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter