DOE Cold Climate Heat Pump Challenge: 137 qualifying heat pumps

Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.

New to heat pump ratings? The Simple view explains them in plain words →

U.S. Department of EnergyData as of updated · sources

Share of models
1.4%
Qualifying models
137
Qualifying certifications
4,698
Paths
1

Criteria

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Challenge specification≥ 8.5≥ 2.1≥ 100%

Source: U.S. Department of Energy

Where the thresholds fall

Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.9327% of rated models reach 2.1 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: DOE CCHP 2.12.10

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%8% of rated models reach 100% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: DOE CCHP 100%100%

Source: AHRI Directory · as of

HSPF29,263 rated models · median 8.661% of rated models reach 8.5 on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8691
6.8 to under 7.067
7.0 to under 7.3239
7.3 to under 7.565
7.5 to under 7.81,051
7.8 to under 8.0534
8.0 to under 8.3814
8.3 to under 8.5123
8.5 to under 8.81,436
8.8 to under 9.0268
9.0 to under 9.3946
9.3 to under 9.5361
9.5 to under 9.8692
9.8 to under 10.0272
10.0 to under 10.3623
10.3 to under 10.5171
10.5 to under 10.8303
10.8 to under 11.079
11.0 to under 11.3175
11.3 to under 11.585
11.5 to under 11.8116
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: DOE CCHP 8.58.5

Source: AHRI Directory · as of

Qualification by size

Share of models meeting DOE CCHP, by size
Show the data as a table
Share of models meeting DOE CCHP, by size
GroupQualifying share
Up to 1.5 tons2.4% · 75 of 3,130
2 tons3.1% · 44 of 1,437
2.5–3 tons0.5% · 14 of 2,588
3.5–4.5 tons0.2% · 4 of 2,136
5 tons and up0% · 0 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted0.7%30 / 4,549
Non-ducted1.9%60 / 3,236
Ducted and non-ducted2.5%47 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric24 of 3736.4%
Rheem16 of 2915.5%
Carrier14 of 7012%
Midea11 of 4022.7%
Fujitsu10 of 1646.1%
LG7 of 789%
Daikin6 of 3671.6%
Samsung5 of 559.1%
Lennox3 of 3131%
KERR2 of 248.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting DOE Cold Climate Heat Pump Challenge, page 2 of 6
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
26CCOXHASZ24HPCustom Comfort · CCO Serieswith ductless indoor unit CCOXHAWM24Custom Comfort2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC5212365407
272MXL18WMVJU*DAIKIN · Daikin AURORADaikin1.5 tons17,800 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.12102%8.716.0CEE 25CEE 26CEE AdvXcelDOEES CC3210722664
28MSH183G26MCAAGOODMAN · MSH Serieswith ductless indoor unit MSH183G26AXAADaikin1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC1214438121
29RXL09WMVJU*DAIKINwith ductless indoor unit FVXS09WVJUDaikin1 ton9,000 Btu/h · Non-ducted2.10100%9.719.5CEE 25CEE 26CEE AdvXcelDOE4212521709
30RXL12WMVJU*DAIKINwith ductless indoor unit FTX12WMVJUDaikin1 ton10,600 Btu/h · Ducted and non-ducted2.26107%10.019.5CEE 25CEE 26CEE AdvXcelDOE5212506076
31RXL15WMVJU*DAIKINwith ductless indoor unit FVXS15WVJUDaikin1.5 tons15,000 Btu/h · Non-ducted2.40100%9.319.5CEE 25CEE 26CEE AdvXcelDOE4212506084
32RZQ36TBVJU*DAIKINwith ducted air handler FXMQ36TBVJUDaikin3 tons35,000 Btu/h · Ducted and non-ducted2.10100%8.816.9CEE 25CEE 26CEE AdvXcelDOE5216521352
33DIRM-24HXPRO28-1ZDIRECT AIR · DIRM serieswith ductless indoor unit DIRM-24HP-WMDIRECT AIR2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC4207743727
34ACIQ-24ZPL-HP230BDIYCOOL · ACIQwith ductless indoor unit ACIQ-24W-HH-MBDIYCOOL2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC5207825553
35DRA1H24S1ADurastar · DRA1with ductless indoor unit DRAF24F1ADurastar2 tons24,000 Btu/h · Ducted and non-ducted2.10100%11.020.5CEE 25CEE 26CEE AdvXcelDOEES CC5210568120
36MOX430U-18HFN1-MECO-AIR · MOX Serieswith ducted air handler MVBE-18HWFN1-MM3EECO-AIR1.5 tons18,000 Btu/h · Ducted2.3099%10.819.3CEE 25CEE 26CEE AdvXcelDOEES CC4213307908
37FRP18AZ24AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHUFriedrich2 tons22,800 Btu/h · Ducted2.10108%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC21213829710
38FRP18AZ36AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHUFriedrich3 tons34,200 Btu/h · Ducted2.20121%8.519.0CEE 25CEE 26CEE AdvXcelDOEES CC23213829722
39AOU18RGLXFUJITSU · H-Serieswith ductless indoor unit AUU18RGLXFujitsu1.5 tons18,000 Btu/h · Ducted and non-ducted2.32101%10.522.0CEE 25CEE 26CEE AdvXcelDOE2202195106
40AOU18RLXFWHFUJITSU · H-Serieswith ductless indoor unit ASU18RLFFujitsu1.5 tons18,000 Btu/h · Non-ducted2.18106%10.020.0CEE 25CEE 26CEE AdvXcelDOEES CC18779045
41AOUG12LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZASFujitsu1 ton12,000 Btu/h · Non-ducted2.16138%12.729.4CEE 25CEE 26CEE AdvXcelDOEES CC2204740069
42AOUG12LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZASFujitsu1 ton12,000 Btu/h · Non-ducted2.32138%12.929.4CEE 25CEE 26CEE AdvXcelDOEES CC2204740068
43AOUG15LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZASFujitsu1 ton14,500 Btu/h · Non-ducted2.12145%12.725.3CEE 25CEE 26CEE AdvXcelDOEES CC2204740071
44AOUG15LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZASFujitsu1 ton14,500 Btu/h · Non-ducted2.24145%12.825.3CEE 25CEE 26CEE AdvXcelDOEES CC2204740070
45AOUH09LMAS1FUJITSU · H-Serieswith ductless indoor unit ASUH09LMASFujitsu1 ton9,000 Btu/h · Non-ducted2.35113%12.626.5CEE 25CEE 26CEE AdvXcelDOEES CC1207615688
46AOUH09LUAS1FUJITSU · H-Serieswith ductless indoor unit ACUH09LUAS1Fujitsu1 ton9,000 Btu/h · Ducted and non-ducted2.23112%11.823.5CEE 25CEE 26CEE AdvXcelDOEES CC2206579743
47AOUH18LPAS1FUJITSUwith ductless indoor unit ASUH18LPASFujitsu1.5 tons18,000 Btu/h · Non-ducted2.14101%10.520.0CEE 25CEE 26CEE AdvXcelDOE1207131734
48FOP1836MJAZCAFUJITSU · F Serieswith indoor coil FCCA6021SZEA and furnace FF75173LT80XFujitsu3 tons34,200 Btu/h · Ducted2.20119%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC14210868911
491U09EH2VHE*HAIER · Arcticwith ductless indoor unit AW09EH2VHDHAIER1 ton9,000 Btu/h · Non-ducted2.11120%14.030.0CEE 25CEE 26CEE AdvXcelDOE1206445819
501U12EH2VHE*HAIER · Arcticwith ductless indoor unit AW12EH2VHDHAIER1 ton12,000 Btu/h · Non-ducted2.31117%12.027.0CEE 25CEE 26CEE AdvXcelDOE1206389351

Explore qualifying models by COP at 5°F