Both views use the same certified data. This device remembers your choice.
DOE Cold Climate Heat Pump Challenge: 138 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
Simple view, for homeowners: top picks by size and what each rating measures →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 1.4%
- Qualifying models
- 138
- Qualifying certifications
- 4,700
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 124 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 118 |
| 1.70 to under 1.80 | 916 |
| 1.80 to under 1.90 | 2,176 |
| 1.90 to under 2.00 | 1,272 |
| 2.00 to under 2.10 | 1,285 |
| 2.10 to under 2.20 | 613 |
| 2.20 to under 2.30 | 484 |
| 2.30 to under 2.40 | 356 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 114 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.91 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 68 |
| 35 to under 40% | 378 |
| 40 to under 45% | 216 |
| 45 to under 50% | 320 |
| 50 to under 55% | 640 |
| 55 to under 60% | 790 |
| 60 to under 65% | 964 |
| 65 to under 70% | 885 |
| 70 to under 75% | 1,102 |
| 75 to under 80% | 505 |
| 80 to under 85% | 543 |
| 85 to under 90% | 414 |
| 90 to under 95% | 386 |
| 95 to under 100% | 274 |
| 100 to under 105% | 389 |
| 105 to under 110% | 73 |
| 110 to under 115% | 81 |
| 115 to under 120% | 28 |
| 120 to under 125% | 46 |
| 125 to under 130% | 12 |
| 130% and above | 32 |
| Baseline: median | 69% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 711 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 263 |
| 7.3 to under 7.5 | 67 |
| 7.5 to under 7.8 | 1,066 |
| 7.8 to under 8.0 | 513 |
| 8.0 to under 8.3 | 818 |
| 8.3 to under 8.5 | 125 |
| 8.5 to under 8.8 | 1,489 |
| 8.8 to under 9.0 | 275 |
| 9.0 to under 9.3 | 959 |
| 9.3 to under 9.5 | 371 |
| 9.5 to under 9.8 | 701 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 635 |
| 10.3 to under 10.5 | 173 |
| 10.5 to under 10.8 | 309 |
| 10.8 to under 11.0 | 81 |
| 11.0 to under 11.3 | 180 |
| 11.3 to under 11.5 | 86 |
| 11.5 to under 11.8 | 117 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons2.4% · 78 of 3,201
- 2 tons3% · 43 of 1,454
- 2.5 to 3 tons0.5% · 14 of 2,633
- 3.5 to 4.5 tons0.1% · 3 of 2,174
- 5 tons and up0% · 0 of 362
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 2.4% · 78 of 3,201 |
| 2 tons | 3% · 43 of 1,454 |
| 2.5 to 3 tons | 0.5% · 14 of 2,633 |
| 3.5 to 4.5 tons | 0.1% · 3 of 2,174 |
| 5 tons and up | 0% · 0 of 362 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 0.6% | 29 / 4,608 |
| Non-ducted | 1.8% | 60 / 3,317 |
| Ducted and non-ducted | 2.6% | 49 / 1,899 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 26MSH183G26MCAAGOODMAN · MSH Serieswith ductless indoor unit MSH183G26AXAANot ranked: cold-weather ratings look inconsistent. | Daikin | 1.5 tons18,000 Btu/h · Non-ducted | 2.89 | 120% | 11.0 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 214438121 |
| 27RXL09WMVJU*DAIKINwith ductless indoor unit FVXS09WVJU | Daikin | 1 ton9,000 Btu/h · Non-ducted | 2.10 | 100% | 9.7 | 19.5 | CEE 25CEE 26CEE AdvXcelDOE | 4 | 212521709 |
| 28RXL12WMVJU*DAIKINwith ductless indoor unit FTX12WMVJU | Daikin | 1 ton10,600 Btu/h · Ducted and non-ducted | 2.26 | 107% | 10.0 | 19.5 | CEE 25CEE 26CEE AdvXcelDOE | 5 | 212506076 |
| 29RXL15WMVJU*DAIKINwith ductless indoor unit FVXS15WVJU | Daikin | 1.5 tons15,000 Btu/h · Non-ducted | 2.40 | 100% | 9.3 | 19.5 | CEE 25CEE 26CEE AdvXcelDOE | 4 | 212506084 |
| 30RZQ36TBVJU*DAIKINwith ducted air handler FXMQ36TBVJU | Daikin | 3 tons35,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 8.8 | 16.9 | CEE 25CEE 26CEE AdvXcelDOE | 5 | 216521352 |
| 31DIRM-24HXPRO28-1ZDIRECT AIR · DIRM serieswith ductless indoor unit DIRM-24HP-WM | DIRECT AIR | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 207743727 |
| 32ACIQ-24ZPL-HP230BDIYCOOL · ACIQwith ductless indoor unit ACIQ-24W-HH-MB | DIYCOOL | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207825553 |
| 33DRA1H24S1ADurastar · DRA1with ductless indoor unit DRAF24F1A | Durastar | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 11.0 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 210568120 |
| 34MOX430U-18HFN1-MECO-AIR · MOX Serieswith ducted air handler MVBE-18HWFN1-MM3E | ECO-AIR | 1.5 tons18,000 Btu/h · Ducted | 2.30 | 99% | 10.8 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 213307908 |
| 35FRP18AZ24AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU | Friedrich | 2 tons22,800 Btu/h · Ducted | 2.10 | 108% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 21 | 213829710 |
| 36FRP18AZ36AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU | Friedrich | 3 tons34,200 Btu/h · Ducted | 2.20 | 121% | 8.5 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 23 | 213829722 |
| 37AOU18RGLXFUJITSU · H-Serieswith ductless indoor unit AUU18RGLX | Fujitsu | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.32 | 101% | 10.5 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 202195106 |
| 38AOU18RLXFWHFUJITSU · H-Serieswith ductless indoor unit ASU18RLF | Fujitsu | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 106% | 10.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 8779045 |
| 39AOUG12LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZAS | Fujitsu | 1 ton12,000 Btu/h · Non-ducted | 2.16 | 138% | 12.7 | 29.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 204740069 |
| 40AOUG12LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZAS | Fujitsu | 1 ton12,000 Btu/h · Non-ducted | 2.32 | 138% | 12.9 | 29.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 204740068 |
| 41AOUG15LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZAS | Fujitsu | 1 ton14,500 Btu/h · Non-ducted | 2.12 | 145% | 12.7 | 25.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 204740071 |
| 42AOUG15LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZAS | Fujitsu | 1 ton14,500 Btu/h · Non-ducted | 2.24 | 145% | 12.8 | 25.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 204740070 |
| 43AOUH09LMAS1FUJITSU · H-Serieswith ductless indoor unit ASUH09LMAS | Fujitsu | 1 ton9,000 Btu/h · Non-ducted | 2.35 | 113% | 12.6 | 26.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 207615688 |
| 44AOUH09LUAS1FUJITSU · H-Serieswith ductless indoor unit ACUH09LUAS1 | Fujitsu | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.23 | 112% | 11.8 | 23.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 206579743 |
| 45AOUH18LPAS1FUJITSUwith ductless indoor unit ASUH18LPAS | Fujitsu | 1.5 tons18,000 Btu/h · Non-ducted | 2.14 | 101% | 10.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 207131734 |
| 46FOP1836MJAZCAFUJITSU · F Serieswith indoor coil FCCA6021SZEA and furnace FF75173LT80X | Fujitsu | 3 tons34,200 Btu/h · Ducted | 2.20 | 119% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 210868911 |
| 47ASH112URDE**GE Appliances · Endurewith ductless indoor unit ASYW12URDE | GE Appliances | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.31 | 117% | 12.5 | 27.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 212409457 |
| 48ASH118URDE**GE Appliances · Endurewith ductless indoor unit ASYW18URDE | GE Appliances | 1.5 tons17,800 Btu/h · Ducted and non-ducted | 2.34 | 100% | 12.0 | 23.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 212409458 |
| 491U09EH2VHE*HAIER · Arcticwith ductless indoor unit AW09EH2VHD | HAIER | 1 ton9,000 Btu/h · Non-ducted | 2.11 | 120% | 14.0 | 30.0 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 206445819 |
| 501U12EH2HE**HAIER · Arcticwith ductless indoor unit AW12EH2HE | HAIER | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.31 | 117% | 12.5 | 27.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 212409448 |