Skip to content

DOE Cold Climate Heat Pump Challenge: 138 qualifying heat pumps

Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.

Simple view, for homeowners: top picks by size and what each rating measures →

U.S. Department of EnergyData as of updated · sources

Share of models
1.4%
Qualifying models
138
Qualifying certifications
4,700
Paths
1

Criteria

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Challenge specification≥ 8.5≥ 2.1≥ 100%

Source: U.S. Department of Energy

Where the thresholds fall

Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.9126% of rated models reach 2.1 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: DOE CCHP 2.12.10

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%8% of rated models reach 100% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: DOE CCHP 100%100%

Source: AHRI Directory · as of

HSPF29,430 rated models · median 8.661% of rated models reach 8.5 on this rating alone.
+45 above31 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.531
6.5 to under 6.8711
6.8 to under 7.067
7.0 to under 7.3263
7.3 to under 7.567
7.5 to under 7.81,066
7.8 to under 8.0513
8.0 to under 8.3818
8.3 to under 8.5125
8.5 to under 8.81,489
8.8 to under 9.0275
9.0 to under 9.3959
9.3 to under 9.5371
9.5 to under 9.8701
9.8 to under 10.0272
10.0 to under 10.3635
10.3 to under 10.5173
10.5 to under 10.8309
10.8 to under 11.081
11.0 to under 11.3180
11.3 to under 11.586
11.5 to under 11.8117
11.8 to under 12.010
12.0 to under 12.332
12.3 to under 12.517
12.5 to under 12.89
12.8 to under 13.04
13.0 to under 13.30
13.3 to under 13.54
13.5 and above45
Baseline: median8.6
Baseline: DOE CCHP 8.58.5

Source: AHRI Directory · as of

Qualification by size

Share of models meeting DOE CCHP, by size
Show the data as a table
Share of models meeting DOE CCHP, by size
GroupQualifying share
Up to 1.5 tons2.4% · 78 of 3,201
2 tons3% · 43 of 1,454
2.5 to 3 tons0.5% · 14 of 2,633
3.5 to 4.5 tons0.1% · 3 of 2,174
5 tons and up0% · 0 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted0.6%29 / 4,608
Non-ducted1.8%60 / 3,317
Ducted and non-ducted2.6%49 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Mitsubishi Electric24 of 4006%
Rheem16 of 2915.5%
Carrier14 of 7012%
Midea11 of 4082.7%
Fujitsu10 of 1646.1%
LG6 of 787.7%
Daikin6 of 3711.6%
Samsung5 of 559.1%
HAIER4 of 537.5%
Lennox3 of 3750.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting DOE Cold Climate Heat Pump Challenge, page 3 of 6
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
511U12EH2VHE*HAIER · Arcticwith ductless indoor unit AW12EH2VHDHAIER1 ton12,000 Btu/h · Non-ducted2.31117%12.027.0CEE 25CEE 26CEE AdvXcelDOE1206389351
521U18EH2HE**HAIER · Arcticwith ductless indoor unit AW18EH2HEHAIER1.5 tons17,800 Btu/h · Ducted and non-ducted2.34100%12.023.0CEE 25CEE 26CEE AdvXcelDOEES CC4212409449
53A-KMH24SU-1AKERR · A serieswith ductless indoor unit B-KMH24UU-1KERR2 tons24,000 Btu/h · Ducted and non-ducted2.10100%11.020.5CEE 25CEE 26CEE AdvXcelDOEES CC4206347323
54A-KMH24SV-1KERR · A serieswith ductless indoor unit B-KMH24SV-1KERR2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC6207657397
55KSIH024-H220-O-2KLIMAIRE · KSI Serieswith ductless indoor unit KUIR24-H2KLIMAIRE2 tons24,000 Btu/h · Ducted and non-ducted2.10100%11.020.5CEE 25CEE 26CEE AdvXcelDOE4209862174
56LBHB24DVWOLBG Products · LBH serieswith ductless indoor unit LMHB24DZDILBG Products2 tons24,000 Btu/h · Ducted and non-ducted2.10102%11.020.5CEE 25CEE 26CEE AdvXcelDOEES CC4208130845
57A-VMH24SV-1COMFORT-AIRE · A-serieswith ductless indoor unit B-VMH24SV-1Lennox2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC12207657389
58MLB024S4S-1PLENNOX · M serieswith ductless indoor unit MWMC024S4-1PLennox2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC14207683523
59MPC009S4S-1PLENNOX · M serieswith ducted air handler MMDB009S4-*PLennox1 ton9,000 Btu/h · Ducted and non-ducted2.4085%10.019.2CEE 25CEE 26CEE AdvXcelDOEES CC11211034423
60ARUN024GSS4LG · ARUN024GSS4LG2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)3.59104%10.218.2CEE 25CEE 26CEE AdvXcelDOEES CC310070562
61LAU090HYV3LG · LAU090HYV3with ductless indoor unit LAN090HYV3LG1 ton9,000 Btu/h · Non-ducted3.13100%13.527.0CEE 25CEE 26CEE AdvXcelDOEES CC1204825177
62LAU120HYV3LG · LAU120HYV3with ductless indoor unit LAN120HYV3LG1 ton12,000 Btu/h · Non-ducted2.91100%11.225.5CEE 25CEE 26CEE AdvXcelDOEES CC1204825178
63LAU150HYV3LG · LAU150HYV3with ductless indoor unit LAN150HYV3LG1.5 tons15,000 Btu/h · Non-ducted2.55105%11.025.0CEE 25CEE 26CEE AdvXcelDOEES CC1204825179
64LAU180HYV3LG · LAU180HYV3with ductless indoor unit LAN180HYV3LG1.5 tons18,000 Btu/h · Non-ducted2.44100%10.824.0CEE 25CEE 26CEE AdvXcelDOEES CC1204825180
65LMU480HHVLG · LMU480HHVLG4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%10.520.5CEE 25CEE 26CEE AdvXcelDOEES CC3206717002
66DLCPRBH18AAKLPS Legacy · DLC-serieswith ductless indoor unit DLFPHBH18XAKNot ranked: cold-weather ratings look inconsistent.LPS Legacy1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC1211756581
67DLCSRBH24AAKLPS Legacy · DLC-serieswith ductless indoor unit DLFSHCH24XAKLPS Legacy2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC8211756584
6838MARBQ24AA3MIDEA · 38MAR-serieswith ductless indoor unit DHMAHBQ24XA3Midea2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC7206350321
6938MPRBQ18AA3MIDEA · 38MP-serieswith ductless indoor unit DHMPHBQ18XA3Not ranked: cold-weather ratings look inconsistent.Midea1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC1207826656
7038MURAQ18AB3MIDEA · 38M serieswith ducted air handler 40MULAQ24XBX + CIMidea1.5 tons18,000 Btu/h · Ducted2.2079%9.516.1CEE 25CEE 26CEE AdvXcelDOEES CC7213372236
71DLCPRBH18AAKMIDEA · DLC-serieswith ductless indoor unit DLFPHBH18XAKNot ranked: cold-weather ratings look inconsistent.Midea1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC1207826650
72DLCSRBH24AAKMIDEA · DLC-serieswith ductless indoor unit DLFSHCH24XAKMidea2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC14208447663
73MOD30-18HFN1-MZ20WMDV · MSEP seriswith ductless indoor unit MSEPD-18HRFN1-MZ22WNot ranked: cold-weather ratings look inconsistent.Midea1.5 tons18,000 Btu/h · Non-ducted2.89120%11.026.3CEE 25CEE 26CEE AdvXcelDOEES CC1207613860
74MOD30-24HFN1-MU0WMDV · MSEP seriswith ductless indoor unit MSEPD-24HRFN1-MU0WMidea2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC10205993855
75MOD30-24HFN1-MU0W-LMDV · MSEP seriswith ductless indoor unit MSEPD-24HRFN1-MU0WMidea2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC5210644038

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy