DOE Cold Climate Heat Pump Challenge: 138 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
Simple view, for homeowners: top picks by size and what each rating measures →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 1.4%
- Qualifying models
- 138
- Qualifying certifications
- 4,700
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 124 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 118 |
| 1.70 to under 1.80 | 916 |
| 1.80 to under 1.90 | 2,176 |
| 1.90 to under 2.00 | 1,272 |
| 2.00 to under 2.10 | 1,285 |
| 2.10 to under 2.20 | 613 |
| 2.20 to under 2.30 | 484 |
| 2.30 to under 2.40 | 356 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 114 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.91 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 68 |
| 35 to under 40% | 378 |
| 40 to under 45% | 216 |
| 45 to under 50% | 320 |
| 50 to under 55% | 640 |
| 55 to under 60% | 790 |
| 60 to under 65% | 964 |
| 65 to under 70% | 885 |
| 70 to under 75% | 1,102 |
| 75 to under 80% | 505 |
| 80 to under 85% | 543 |
| 85 to under 90% | 414 |
| 90 to under 95% | 386 |
| 95 to under 100% | 274 |
| 100 to under 105% | 389 |
| 105 to under 110% | 73 |
| 110 to under 115% | 81 |
| 115 to under 120% | 28 |
| 120 to under 125% | 46 |
| 125 to under 130% | 12 |
| 130% and above | 32 |
| Baseline: median | 69% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 31 |
| 6.5 to under 6.8 | 711 |
| 6.8 to under 7.0 | 67 |
| 7.0 to under 7.3 | 263 |
| 7.3 to under 7.5 | 67 |
| 7.5 to under 7.8 | 1,066 |
| 7.8 to under 8.0 | 513 |
| 8.0 to under 8.3 | 818 |
| 8.3 to under 8.5 | 125 |
| 8.5 to under 8.8 | 1,489 |
| 8.8 to under 9.0 | 275 |
| 9.0 to under 9.3 | 959 |
| 9.3 to under 9.5 | 371 |
| 9.5 to under 9.8 | 701 |
| 9.8 to under 10.0 | 272 |
| 10.0 to under 10.3 | 635 |
| 10.3 to under 10.5 | 173 |
| 10.5 to under 10.8 | 309 |
| 10.8 to under 11.0 | 81 |
| 11.0 to under 11.3 | 180 |
| 11.3 to under 11.5 | 86 |
| 11.5 to under 11.8 | 117 |
| 11.8 to under 12.0 | 10 |
| 12.0 to under 12.3 | 32 |
| 12.3 to under 12.5 | 17 |
| 12.5 to under 12.8 | 9 |
| 12.8 to under 13.0 | 4 |
| 13.0 to under 13.3 | 0 |
| 13.3 to under 13.5 | 4 |
| 13.5 and above | 45 |
| Baseline: median | 8.6 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons2.4% · 78 of 3,201
- 2 tons3% · 43 of 1,454
- 2.5 to 3 tons0.5% · 14 of 2,633
- 3.5 to 4.5 tons0.1% · 3 of 2,174
- 5 tons and up0% · 0 of 362
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 2.4% · 78 of 3,201 |
| 2 tons | 3% · 43 of 1,454 |
| 2.5 to 3 tons | 0.5% · 14 of 2,633 |
| 3.5 to 4.5 tons | 0.1% · 3 of 2,174 |
| 5 tons and up | 0% · 0 of 362 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 0.6% | 29 / 4,608 |
| Non-ducted | 1.8% | 60 / 3,317 |
| Ducted and non-ducted | 2.6% | 49 / 1,899 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 126AC036BXSCCHSAMSUNG · 4-Way Cassette (WindFree™) Max Heatwith ductless indoor unit AC036BN4DCH | Samsung | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.12 | 107% | 9.1 | 21.6 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 207698071 |
| 127AC048BXUPCHSAMSUNGwith ducted air handler L(E,G)M48D4 | Samsung | 4 tons47,500 Btu/h · Ducted | 2.35 | 105% | 8.5 | 17.0 | CEE AdvDOEES CC | 6 | 213350965 |
| 128AC060BXUPCHSAMSUNGwith ducted air handler L(E,G)M60E4 | Samsung | 4.5 tons56,500 Btu/h · Ducted | 2.34 | 102% | 9.0 | 17.5 | CEE AdvDOEES CC | 4 | 213350966 |
| 129AR09CSDABWKXSAMSUNG · WindFree™ 3.0 (RAC)with ductless indoor unit AR09CSDABWKN | Samsung | 1 ton9,000 Btu/h · Non-ducted | 2.25 | 133% | 10.5 | 24.5 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 210445757 |
| 130HSZ24H424ZMOSEA BREEZE+ · HS serieswith ductless indoor unit FC24H424ZMI | SEA BREEZE+ | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 11.0 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 212595656 |
| 131SENA/24HF/OQSENVILLE · SEN serieswith ductless indoor unit SENA/24HF/IQ | Senville | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207657630 |
| 132SHC24VH2AGSLIMAIR · SHC Serieswith ductless indoor unit SHS24VC2AG | SLIMAIR | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 11.0 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 214728305 |
| 133ACIQ-24ZPL-HP230BSTEALTH · ACIQwith ductless indoor unit ACIQ-24W-HH-MB | STEALTH | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 212316160 |
| 1344TXD2036A10NU**TRANEwith ducted air handler F,PE*E32930 | Trane | 2 tons23,000 Btu/h · Ducted | 2.10 | 107% | 8.9 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 65 | 212396546 |
| 135OAH24H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ductless indoor unit IUMW124H/I41P | TRUST AIR CONDITIONERS | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 208816917 |
| 136DLCPRBH18AAKViessmann · DLC-serieswith ductless indoor unit DLFPHBH18XAKNot ranked: cold-weather ratings look inconsistent. | Viessmann | 1.5 tons18,000 Btu/h · Non-ducted | 2.89 | 120% | 11.0 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215569835 |
| 137DLCSRBH24AAKViessmann · DLC-serieswith ductless indoor unit DLFSHCH24XAK | Viessmann | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 215569840 |
| 138HMH72B341LUXAIREwith indoor coil D(A,C,E)36A34+TDR and furnace LP9C120D20MP13 | York | 2.5 tons31,200 Btu/h · Ducted | 3.21 | 78% | 8.5 | 16.8 | CEE 25CEE 26CEE AdvXcelDOEES CC | 13,786 | 214092242 |