Skip to content

ENERGY STAR Cold Climate: 2,434 qualifying heat pumps

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

New to heat pump ratings? The Simple view explains them in plain words →

U.S. EPAData as of updated · sources

Share of models
25.1%
Qualifying models
2,434
Qualifying certifications
12,910
Paths
Listing

Criteria

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.

Source: U.S. EPA

Qualification by size

Share of models meeting ENERGY STAR CC, by size
Show the data as a table
Share of models meeting ENERGY STAR CC, by size
GroupQualifying share
Up to 1.5 tons34.8% · 1,090 of 3,130
2 tons30.4% · 438 of 1,440
2.5–3 tons18.3% · 477 of 2,606
3.5–4.5 tons19% · 410 of 2,161
5 tons and up5.3% · 19 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted14.9%686 / 4,597
Non-ducted24.2%782 / 3,236
Ducted and non-ducted51.9%966 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree176 of 39544.6%
Midea152 of 40237.8%
Mitsubishi Electric139 of 37337.3%
Hisense75 of 15947.2%
Lennox62 of 37116.7%
Carrier62 of 7018.8%
Fujitsu46 of 16428%
Rheem45 of 29115.5%
BlueRidge39 of 8347%
ECO AC36 of 4973.5%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting ENERGY STAR Cold Climate, page 53 of 98
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1301ODUM3OK-27HFN1-MKepler · IDU SeriesKepler2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.92103%10.021.8CEE 25CEE 26XcelES CC3214377779
1302ODUM3OK-27HFN1-M*Kepler · ODU SeriesKepler2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%10.623.0CEE 25CEE 26XcelES CC3216051351
1303ODUM4OI-36HFN1-MKepler · IDU SeriesKepler3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%10.322.2CEE 25CEE 26XcelES CC3214377782
1304ODUM4OX630-36HFN1-M1XKepler · IDU SeriesKepler3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00103%10.922.4CEE 25CEE 26XcelES CC3214377785
1305ODUM5OA-55HFN1-M-[X]Kepler · IDU SeriesKepler4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.522.0CEE 25CEE 26XcelES CC3214377791
1306ODUM5OG-48HFN1-M-[X]Kepler · IDU SeriesKepler4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%9.821.8CEE 25CEE 26XcelES CC3214377788
1307ODUMOD30-24HFN1MU0WKepler · IDU Serieswith ductless indoor unit IDUMSEPD-24HRFN1MU0WKepler2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26XcelES CC3213608176
1308ODUMOD30-33HFN1MSR0WKepler · IDU Serieswith ductless indoor unit IDUMSEPD-33HRFN1MSR0WKepler3 tons33,000 Btu/h · Non-ducted1.8099%10.019.5CEE 25CEE 26XcelES CC1213608177
1309ODUMOD33-24HFN1-MT0WKepler · IDU Serieswith ducted air handler IDUMTIU-24HWFN1-MKepler2 tons23,000 Btu/h · Ducted and non-ducted2.3080%11.219.0CEE 25CEE 26XcelES CC3214610367
1310ODUMOX230-09HFN1-BS5WKepler · IDU Serieswith ductless indoor unit IDUMSAG11A-09HRFN1-BS5WKepler1 ton9,000 Btu/h · Non-ducted2.1670%9.121.5CEE 25CEE 26XcelES CC2214610350
1311ODUMOX230-09HFN1-MT0WKepler · IDU Serieswith ductless indoor unit IDUMSAG11A-09HRFN1-MT0WKepler1 ton9,000 Btu/h · Non-ducted1.9970%9.421.7CEE 25CEE 26XcelES CC2214610352
1312ODUMOX230-09HFN1-MW5WKepler · IDU Serieswith ductless indoor unit IDUMSEPB-09HRFN1-MY5W(GA)Kepler1 ton9,000 Btu/h · Ducted and non-ducted2.1986%12.325.5CEE 25CEE 26XcelES CC4214610360
1313ODUMOX230-12HFN1-MV5WKepler · IDU Serieswith ductless indoor unit IDUMFA2U-12HRFN1-MW5WKepler1 ton12,000 Btu/h · Ducted and non-ducted2.4572%11.025.0CEE 25CEE 26XcelES CC4214610372
1314ODUMOX330-09HFN1MY5WKepler · IDU Serieswith ductless indoor unit IDUMSEPB-09HRFN1MY5W(GA)Kepler1 ton9,000 Btu/h · Ducted and non-ducted1.9788%11.528.1CEE 25CEE 26XcelES CC3213608173
1315ODUMOX330-12HFN1MW5WKepler · IDU Serieswith ductless indoor unit IDUMFA2U-12HRFN1-MW5WKepler1 ton12,000 Btu/h · Ducted and non-ducted1.9999%10.724.2CEE 25CEE 26XcelES CC4214377775
1316ODUMOX430-17HFN1MT0WKepler · IDU Serieswith ducted air handler IDUMTIU-18HWFN1-MKepler1.5 tons17,000 Btu/h · Ducted and non-ducted1.8593%9.518.0CEE 25CEE 26XcelES CC3214377769
1317A-KCD18SA-1KERR · A-serieswith ducted air handler MCD18/24B1AKERR1.5 tons18,000 Btu/h · Ducted2.2079%9.516.1CEE 25CEE 26XcelES CC4213265615
1318A-KCD24SA-1KERR · A-KCD serieswith ducted air handler MCD18/24B1AKERR2 tons24,000 Btu/h · Ducted1.9580%9.516.5CEE 25CEE 26XcelES CC5212631694
1319A-KCD30SA-1KERRwith ducted air handler *E31930+TDKERR2.5 tons28,600 Btu/h · Ducted1.9592%9.115.2CEE 25CEE 26XcelES CC12213255487
1320A-KCD36SA-1KERR · A-KCD serieswith ducted air handler MCD30/36C1AKERR3 tons35,000 Btu/h · Ducted2.0082%10.015.2CEE 25CEE 26XcelES CC6212631696
1321A-KCD48SA-1KERR · A-serieswith ducted air handler B-VCD48SA-1KERR4 tons47,000 Btu/h · Ducted1.9092%9.415.6ES CC3213348326
1322A-KCD60SA-1KERR · A-KCD serieswith ducted air handler B-KCD60SA-1KERR4.5 tons55,000 Btu/h · Ducted1.9182%9.415.3ES CC3210857424
1323A-KMH06SV-1KERR · A serieswith ductless indoor unit B-KMH06SV-1KERR0.5 tons6,000 Btu/h · Non-ducted2.09107%13.626.5CEE 25CEE 26XcelES CC1207657393
1324A-KMH09SV-1KERR · A serieswith ductless indoor unit B-KMH09SV-1KERR1 ton9,000 Btu/h · Ducted and non-ducted1.9788%11.528.1CEE 25CEE 26XcelES CC4207657394
1325A-KMH12SV-1KERR · A-serieswith ductless indoor unit B-KMH12FV-1KERR1 ton12,000 Btu/h · Ducted and non-ducted1.9999%10.724.2CEE 25CEE 26XcelES CC6213916259

Explore qualifying models by COP at 5°F