Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,627 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.6%
Qualifying models
3,627
Qualifying certifications
83,155
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,263 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5987
15.5 to under 16.0347
16.0 to under 16.5716
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,263 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,156
11.0 to under 11.5964
11.5 to under 12.01,096
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,694 of 3,130
2 tons46.3% · 666 of 1,437
2.5–3 tons31.3% · 810 of 2,588
3.5–4.5 tons20.1% · 429 of 2,136
5 tons and up8% · 28 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.5%934 / 4,549
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,299 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Lennox92 of 31329.4%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 10 of 146
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
226ASLCI4H4S09AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S09AIR-CON1 ton9,000 Btu/h · Ducted and non-ducted2.2583%10.020.5CEE 25CEE 26XcelES CC2205129515
227ASLCI4H4S12AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S12AIR-CON1 ton12,000 Btu/h · Ducted and non-ducted2.3171%9.520.5CEE 25CEE 26XcelES CC2205129518
228ASLCI4H4S18AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S18AIR-CON1.5 tons18,000 Btu/h · Ducted and non-ducted2.3670%10.020.5CEE 25CEE 26XcelES CC2205129519
229ASLCI4H4S24AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S24AIR-CON2 tons24,000 Btu/h · Ducted and non-ducted2.2073%10.018.5CEE 25CEE 26XcelES CC2205129521
230ASLCI4H4S36AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S36AIR-CON3 tons36,000 Btu/h · Ducted and non-ducted2.2874%9.818.0CEE 25CEE 26Xcel2205150423
231ASXCI4H4E12AIR-CON · Blue Series 4with ductless indoor unit ASXEM4H4E12AIR-CON1 ton12,000 Btu/h · Non-ducted1.8076%9.523.0CEE 25CEE 26XcelES CC1214866724
232ACSH0924VM2-DAIRDACHwith ductless indoor unit AIWH0900VM2-DAIRDACH1 ton9,000 Btu/h · Non-ducted2.1165%11.424.0CEE 25CEE 26Xcel2209948205
233ACSH1823VM2-DAIRDACHwith ductless indoor unit AIWH1800VM2-DAIRDACH1.5 tons18,000 Btu/h · Non-ducted2.3870%10.323.7CEE 25CEE 26Xcel2209948207
234AMSH1800VM1-DAIRDACHAIRDACH1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8674%10.221.0CEE 25CEE 26Xcel3210474671
235AMSH2700VM1-DAIRDACHAIRDACH2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0067%9.221.0CEE 25CEE 26Xcel3210474675
236AMSH4800VM1-DAIRDACHAIRDACH4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8071%9.521.1CEE 25CEE 26Xcel3210474680
237GXH09(2.6)LSK4DL2AireForcewith ductless indoor unit GHH09(2.6)LSK4DL2AireForce1 ton9,000 Btu/h · Non-ducted1.7679%8.417.5Xcel1211635182
238GXH12(3.5)LSK4DH2AireForcewith ductless indoor unit GKH12(3.5)FMK4DH1AireForce1 ton12,000 Btu/h · Non-ducted1.9077%8.524.0CEE 25CEE 26XcelES CC2212925552
239GXH18(5.3)FMK4DH-1AireForce · Flex MatchAireForce1.5 tons17,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2176%10.021.0CEE 25CEE 26XcelES CC3211635192
240GXH18(5.3)LSK4DH2AireForcewith ductless indoor unit GKH18(5.3)FMK4DH1AireForce1.5 tons18,000 Btu/h · Non-ducted1.9381%8.519.0CEE 25CEE 26Xcel2212925555
241GXH24-36MSK4DHAireForce · Ultra Side Dischargewith ducted air handler GMH24-**MSK4DH1AireForce2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26XcelES CC4206724404
242GXH24(7.0)FMK4DH-1AireForce · Flex MatchAireForce2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.0CEE 25CEE 26XcelES CC3211635193
243GXH24(7.0)LSK4DHAireForcewith ductless indoor unit GHH24(7.0)LUK4DHAireForce2 tons22,000 Btu/h · Non-ducted1.7583%8.520.0CEE 25CEE 26Xcel1202534242
244GXH30(8.8)FMK4DH-1AireForce · Flex MatchAireForce2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8476%10.021.0CEE 25CEE 26XcelES CC3211635194
245GXH30(8.8)LSK4DH2AireForcewith ductless indoor unit GHH30(8.8)LUK4DH2AireForce2.5 tons30,000 Btu/h · Non-ducted1.8177%8.520.0CEE 25CEE 26Xcel1211635190
246GXH36(10.6)FMK4DH-1AireForce · Flex MatchAireForce3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8290%10.021.0CEE 25CEE 26XcelES CC3211635195
247GXH36(10.6)LSK4DH2AireForcewith ductless indoor unit GHH36(10.6)LUK4DH2AireForce3 tons33,600 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel1211635191
248GXH42(12.3)FMK4DH-1AireForce · Flex MatchAireForce3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9281%10.021.0CEE 25CEE 26XcelES CC3211635196
249GXH48-60MSK4DHAireForce · Ultra Side Dischargewith ducted air handler GMH48-**MSK4DH1AireForce4 tons48,000 Btu/h · Ducted1.8081%9.017.0CEE 25CEE 26XcelES CC4206724406
250GXH09(2.6)LSK4DL2AIRTEMPwith ductless indoor unit GHH09(2.6)LSK4DL2AIRTEMP1 ton9,000 Btu/h · Non-ducted1.7679%8.417.5Xcel1210534157

Explore qualifying models by COP at 5°F