Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,653 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.7%
Qualifying models
3,653
Qualifying certifications
83,192
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,806 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50123
1.50 to under 1.6087
1.60 to under 1.70115
1.70 to under 1.80716
1.80 to under 1.902,089
1.90 to under 2.001,247
2.00 to under 2.101,265
2.10 to under 2.20607
2.20 to under 2.30477
2.30 to under 2.40345
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,798 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%366
40 to under 45%200
45 to under 50%286
50 to under 55%599
55 to under 60%783
60 to under 65%885
65 to under 70%799
70 to under 75%1,049
75 to under 80%488
80 to under 85%537
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%387
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,312 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.51,004
15.5 to under 16.0355
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5371
18.5 to under 19.0279
19.0 to under 19.5593
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,312 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,175
11.0 to under 11.5983
11.5 to under 12.01,096
12.0 to under 12.5918
12.5 to under 13.01,266
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,130
2 tons46.4% · 668 of 1,440
2.5–3 tons31.4% · 818 of 2,606
3.5–4.5 tons20.6% · 446 of 2,161
5 tons and up7.8% · 28 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.8%956 / 4,597
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,303 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Lennox121 of 37132.6%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 111 of 147
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2751GXH30(8.8)FMK4DH-1GIBSON · Flex MatchNortek Global HVAC2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8476%10.021.0CEE 25CEE 26XcelES CC3210276802
2752GXH30(8.8)LSK4DH2GIBSONwith ductless indoor unit GHH30(8.8)LUK4DH2Nortek Global HVAC2.5 tons30,000 Btu/h · Non-ducted1.8177%8.520.0CEE 25CEE 26Xcel1210534173
2753GXH36(10.6)FMK4DH-1GIBSON · Flex MatchNortek Global HVAC3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8290%10.021.0CEE 25CEE 26XcelES CC3210276798
2754GXH36(10.6)LSK4DH2GIBSONwith ductless indoor unit GHH36(10.6)LUK4DH2Nortek Global HVAC3 tons33,600 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel1210534174
2755GXH42(12.3)FMK4DH-1GIBSON · Flex MatchNortek Global HVAC3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9281%10.021.0CEE 25CEE 26XcelES CC3210276799
2756GXH48-60MSK4DHNORTEK · Ultra Side Dischargewith ducted air handler GMH48-**MSK4DH1Nortek Global HVAC4 tons48,000 Btu/h · Ducted1.8081%9.017.0CEE 25CEE 26XcelES CC12206724398
2757WHM36SZA21SWESTINGHOUSEwith ducted air handler WHM36DMA21SNortek Global HVAC3 tons36,000 Btu/h · Ducted2.1070%9.018.0Xcel33207506890
2758WHM48SZA21SWESTINGHOUSE · WH ULTRA HD-COILwith ducted air handler DC61A44-245RNortek Global HVAC3.5 tons42,000 Btu/h · Ducted1.9482%8.615.6CEE 25CEE 26XcelES CC29213886028
2759WHP07SZA21SWESTINGHOUSEwith ductless indoor unit WHP42M5A21SNortek Global HVAC1 ton9,000 Btu/h · Non-ducted1.8070%9.022.0CEE 25CEE 26Xcel1206724416
2760WHP09SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHP09WMA21SNortek Global HVAC1 ton9,000 Btu/h · Non-ducted2.0780%9.022.0CEE 25CEE 26XcelES CC1205417832
2761WHP12SZA21SWESTINGHOUSEwith ductless indoor unit WHP12WMA21SNortek Global HVAC1 ton12,000 Btu/h · Non-ducted1.8580%9.521.0CEE 25CEE 26Xcel1205417834
2762WHP18M2A21SWESTINGHOUSE · Hi MULTI XtremeNortek Global HVAC1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%9.521.0CEE 25CEE 26XcelES CC3205470408
2763WHP18SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHP18WMA21SNortek Global HVAC1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26XcelES CC1205417836
2764WHP24M3A21SWESTINGHOUSE · Hi MULTI XtremeNortek Global HVAC2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%9.122.0CEE 25CEE 26XcelES CC3205470409
2765WHP24SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHP24WMA21SNortek Global HVAC2 tons23,000 Btu/h · Non-ducted2.1389%8.620.5CEE 25CEE 26XcelES CC1205417838
2766WHP36M4A21SWESTINGHOUSE · Hi MULTI XtremeNortek Global HVAC2.5 tons32,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.84113%9.021.0CEE 25CEE 26XcelES CC3205446269
2767WHP42M5A21SWESTINGHOUSE · Hi MULTI XtremeNortek Global HVAC3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8486%9.020.0CEE 25CEE 26XcelES CC4206517597
2768WHU09SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHU09CTA21SNortek Global HVAC1 ton9,000 Btu/h · Ducted and non-ducted2.1992%10.020.5CEE 25CEE 26XcelES CC2207237535
2769WHU12SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHU12CTA21SNortek Global HVAC1 ton12,000 Btu/h · Ducted and non-ducted2.3171%9.520.5CEE 25CEE 26XcelES CC2207237536
2770WHU18SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHU18CTA21SNortek Global HVAC1.5 tons18,000 Btu/h · Ducted and non-ducted2.3673%10.020.5CEE 25CEE 26XcelES CC2207237537
2771WHU24SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHU24CTA21SNortek Global HVAC2 tons24,000 Btu/h · Ducted and non-ducted2.2079%10.018.5CEE 25CEE 26XcelES CC2207237538
2772WHU36SZA21SWESTINGHOUSEwith ductless indoor unit WHU36CTA21SNortek Global HVAC3 tons36,000 Btu/h · Ducted and non-ducted2.2874%9.818.0CEE 25CEE 26Xcel2207237539
2773WHZ09SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHZ09WMA21SNortek Global HVAC1 ton9,000 Btu/h · Non-ducted2.0589%10.527.5CEE 25CEE 26XcelES CC1207337194
2774WHZ12SZA21SWESTINGHOUSE · Hi UNIwith ductless indoor unit WHZ12WMA21SNortek Global HVAC1 ton12,000 Btu/h · Non-ducted1.9581%9.823.5CEE 25CEE 26XcelES CC1207337195
2775OHP-12-22-23-ANORTON AIR CONDITIONERS · OHP Serieswith ductless indoor unit DHP-12-12-U-ANORTON AIR CONDITIONERS1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC1217500257

Explore qualifying models by COP at 5°F