Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel Energy Colorado cold-climate ASHP (2025): 3,653 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
New to heat pump ratings? The Simple view explains them in plain words →
Xcel EnergyData as of updated · sources
- Share of models
- 37.7%
- Qualifying models
- 3,653
- Qualifying certifications
- 83,192
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 123 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 115 |
| 1.70 to under 1.80 | 716 |
| 1.80 to under 1.90 | 2,089 |
| 1.90 to under 2.00 | 1,247 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 607 |
| 2.20 to under 2.30 | 477 |
| 2.30 to under 2.40 | 345 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 366 |
| 40 to under 45% | 200 |
| 45 to under 50% | 286 |
| 50 to under 55% | 599 |
| 55 to under 60% | 783 |
| 60 to under 65% | 885 |
| 65 to under 70% | 799 |
| 70 to under 75% | 1,049 |
| 75 to under 80% | 488 |
| 80 to under 85% | 537 |
| 85 to under 90% | 414 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 387 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 678 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 1,004 |
| 15.5 to under 16.0 | 355 |
| 16.0 to under 16.5 | 714 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 371 |
| 18.5 to under 19.0 | 279 |
| 19.0 to under 19.5 | 593 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 388 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,175 |
| 11.0 to under 11.5 | 983 |
| 11.5 to under 12.0 | 1,096 |
| 12.0 to under 12.5 | 918 |
| 12.5 to under 13.0 | 1,266 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons54.1% · 1,693 of 3,130
- 2 tons46.4% · 668 of 1,440
- 2.5–3 tons31.4% · 818 of 2,606
- 3.5–4.5 tons20.6% · 446 of 2,161
- 5 tons and up7.8% · 28 of 358
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 54.1% · 1,693 of 3,130 |
| 2 tons | 46.4% · 668 of 1,440 |
| 2.5–3 tons | 31.4% · 818 of 2,606 |
| 3.5–4.5 tons | 20.6% · 446 of 2,161 |
| 5 tons and up | 7.8% · 28 of 358 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 20.8% | 956 / 4,597 |
| Non-ducted | 43.1% | 1,394 / 3,236 |
| Ducted and non-ducted | 70% | 1,303 / 1,862 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 223 of 395 | 56.5% |
| Mitsubishi Electric | 200 of 373 | 53.6% |
| Midea | 180 of 402 | 44.8% |
| Lennox | 121 of 371 | 32.6% |
| Carrier | 120 of 701 | 17.1% |
| Rheem | 102 of 291 | 35.1% |
| Hisense | 94 of 159 | 59.1% |
| Trane | 68 of 309 | 22% |
| Fujitsu | 56 of 164 | 34.1% |
| Daikin | 55 of 367 | 15% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 2976RGWI-CW09H1AT-01RHEEMwith ductless indoor unit RGWI-EW09H1AT-01 | Rheem | 1 ton9,100 Btu/h · Non-ducted | 1.77 | 75% | 8.6 | 19.5 | CEE 25CEE 26Xcel | 1 | 211174338 |
| 2977RGWI-CW09H2AT-01RHEEMwith ductless indoor unit RGWI-EW09H2AT-01 | Rheem | 1 ton9,100 Btu/h · Non-ducted | 1.81 | 74% | 8.8 | 19.5 | CEE 25CEE 26Xcel | 1 | 211174339 |
| 2978RGWI-CW30H2AT-01RHEEMwith ductless indoor unit RGWI-EW30H2AT-01 | Rheem | 2.5 tons30,000 Btu/h · Non-ducted | 1.81 | 77% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 211174344 |
| 2979RGWI-CW36H2AT-01RHEEMwith ductless indoor unit RGWI-EW36H2AT-01 | Rheem | 3 tons33,600 Btu/h · Non-ducted | 1.85 | 71% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 211174345 |
| 2980RO1HFZ09AJ2HRHEEM · Classicwith ductless indoor unit RIFHFZ09AJ2S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 112% | 11.6 | 26.0 | CEE 25CEE 26Xcel | 2 | 210368082 |
| 2981RO1HFZ09AJ2SRUUD · Classicwith ductless indoor unit RIFHFZ09AJ2S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 1.98 | 119% | 11.8 | 26.0 | CEE 25CEE 26Xcel | 2 | 210368077 |
| 2982RO1HFZ12AJ2HRHEEM · Classicwith ductless indoor unit RIFHFZ12AJ2S | Rheem | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 84% | 11.0 | 22.7 | CEE 25CEE 26Xcel | 2 | 210368084 |
| 2983RO1HFZ12AJ2SRHEEM · Classicwith ductless indoor unit RIFHFZ12AJ2S | Rheem | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 84% | 11.2 | 22.7 | CEE 25CEE 26Xcel | 2 | 210368078 |
| 2984RO1HFZ15AJ2HRHEEM · Classicwith ductless indoor unit RIFHFZ15AJ2S | Rheem | 1 ton14,200 Btu/h · Non-ducted | 1.84 | 101% | 10.5 | 20.3 | CEE 25CEE 26Xcel | 2 | 210368086 |
| 2985RO1HFZ15AJ2SRUUD · Classic Pluswith ductless indoor unit RIFHFZ15AJ2S | Rheem | 1 ton14,200 Btu/h · Non-ducted | 1.91 | 105% | 10.7 | 20.3 | CEE 25CEE 26Xcel | 2 | 210368081 |
| 2986RO1HFZ18AJ2HRHEEM · Classic Pluswith ductless indoor unit RIWHFZ18AJ2S | Rheem | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 88% | 10.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368088 |
| 2987RO1HFZ24AJ2HRHEEM · Classic Pluswith ductless indoor unit RIWHFZ24AJ2S | Rheem | 2 tons22,000 Btu/h · Non-ducted | 2.04 | 92% | 10.5 | 19.5 | CEE 25CEE 26Xcel | 2 | 210368090 |
| 2988RO1HFZ30AJ2HRUUD · Classic Pluswith ductless indoor unit UIWHFZ30AJ2S | Rheem | 2.5 tons30,000 Btu/h · Non-ducted | 2.06 | 100% | 10.0 | 18.7 | CEE 25CEE 26Xcel | 2 | 210368093 |
| 2989RO1HGZ09AJ1HRUUD · Classic Pluswith ductless indoor unit UIWHGZ09AJ1S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.01 | 128% | 13.3 | 33.1 | CEE 25CEE 26Xcel | 2 | 210368101 |
| 2990RO1HGZ09AJ1SRUUD · Classic Pluswith ductless indoor unit UIWHGZ09AJ1S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.15 | 128% | 13.4 | 33.1 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368099 |
| 2991RO1HGZ12AJ1HRHEEM · Classic Pluswith ductless indoor unit RIWHGZ12AJ1S | Rheem | 1 ton12,000 Btu/h · Non-ducted | 2.16 | 104% | 12.7 | 29.4 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368104 |
| 2992RO1HGZ12AJ1SRHEEM · Classic Pluswith ductless indoor unit RIWHGZ12AJ1S | Rheem | 1 ton12,000 Btu/h · Non-ducted | 2.32 | 104% | 12.9 | 29.4 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368102 |
| 2993RO1HGZ15AJ1HRHEEM · Prestigewith ductless indoor unit RIWHGZ15AJ1S | Rheem | 1 ton14,500 Btu/h · Non-ducted | 2.34 | 97% | 12.7 | 25.3 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368108 |
| 2994RO1HGZ15AJ1SRHEEM · Prestigewith ductless indoor unit RIWHGZ15AJ1S | Rheem | 1 ton14,500 Btu/h · Non-ducted | 2.52 | 97% | 12.8 | 25.3 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210368106 |
| 2995RO1HGZ42AJ8SRHEEMwith ducted air handler RIMHGZ42AJ8S | Rheem | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.28 | 75% | 9.8 | 17.3 | CEE 25CEE 26Xcel | 4 | 210824726 |
| 2996RO1HGZ48AJ8SRHEEMwith ducted air handler RIMHGZ48AJ8S | Rheem | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.22 | 68% | 9.0 | 16.4 | CEE 25CEE 26Xcel | 4 | 210824732 |
| 2997RO1HHZ09AJ2HRHEEM · Prestigewith ductless indoor unit RIWHHZ09AJ2S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 78% | 12.3 | 26.5 | CEE 25CEE 26Xcel | 2 | 210368094 |
| 2998RO1HHZ09AJ2SRHEEM · Prestigewith ductless indoor unit RIWHHZ09AJ2S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.36 | 84% | 12.6 | 26.5 | CEE 25CEE 26Xcel | 2 | 210368126 |
| 2999RO1HHZ09AJ3SRHEEM · Prestigewith ductless indoor unit RIWHHZ09AJ3S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.06 | 67% | 10.5 | 20.0 | CEE 25CEE 26Xcel | 2 | 210368112 |
| 3000RO1HHZ09AJ8SRHEEM · Prestigewith ductless indoor unit RICHHZ09AJ8S | Rheem | 1 ton9,000 Btu/h · Non-ducted | 2.22 | 84% | 11.8 | 23.5 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 210824705 |