Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,624 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.6%
Qualifying models
3,624
Qualifying certifications
83,159
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,755 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,084
1.90 to under 2.001,248
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30469
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,747 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%529
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,260 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5986
15.5 to under 16.0347
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,260 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0387
10.0 to under 10.5900
10.5 to under 11.01,155
11.0 to under 11.5964
11.5 to under 12.01,095
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,129
2 tons46.3% · 665 of 1,436
2.5–3 tons31.3% · 809 of 2,587
3.5–4.5 tons20.1% · 429 of 2,136
5 tons and up8% · 28 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.5%931 / 4,546
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,299 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Lennox92 of 31329.4%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 122 of 147
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
3026ROSH15AFFJRHEEMwith ductless indoor unit RIFH15AVFJRheem1 ton14,200 Btu/h · Non-ducted1.84101%10.720.3CEE 25CEE 26Xcel210595396
3027ROSH18AHXHJRHEEMwith ductless indoor unit RIWH18AVFJRheem1.5 tons18,000 Btu/h · Non-ducted2.1888%10.020.0CEE 25CEE 26CEE AdvXcelDOE210595377
3028ROSH18VGSNRHEEMwith ductless indoor unit RICH18AXCJRheem1.5 tons18,000 Btu/h · Ducted and non-ducted2.3286%10.522.0CEE 25CEE 26CEE AdvXcelDOE4202244046
3029ROSH24AHXHJRHEEMwith ductless indoor unit RIWH24AVFJRheem2 tons22,000 Btu/h · Non-ducted2.0492%10.519.5CEE 25CEE 26Xcel210595379
3030ROSH24VGSNRHEEMwith ductless indoor unit RICH24AXCJRheem2 tons24,000 Btu/h · Ducted and non-ducted2.0486%10.120.8CEE 25CEE 26Xcel4202244731
3031ROSH30AHXHJRHEEMwith ductless indoor unit RIWH30AVFJRheem2.5 tons30,000 Btu/h · Non-ducted2.0295%10.018.7CEE 25CEE 26Xcel210595381
3032ROSH30VGSNRHEEMwith ductless indoor unit RICH30AXCJRheem2.5 tons30,000 Btu/h · Ducted and non-ducted2.3081%10.418.7CEE 25CEE 26Xcel4202245032
3033ROSH36VGSNRHEEMwith ductless indoor unit RICH36AXCJRheem3 tons36,000 Btu/h · Ducted and non-ducted2.3274%9.718.0CEE 25CEE 26Xcel4202245794
3034ROSH42VGSNRHEEMwith ductless indoor unit RICH42AXCJRheem3.5 tons42,000 Btu/h · Ducted and non-ducted2.2881%9.819.0CEE 25CEE 26Xcel4202245810
3035ROSH48VGSNRHEEMwith ducted air handler RIDH48AXCJRheem4 tons48,000 Btu/h · Ducted and non-ducted2.2275%9.016.4CEE 25CEE 26Xcel4207590037
3036RP15AZ18AJ2NRUUDwith indoor coil CP31A34+TDR and furnace R921V0603A17M4SRheem1.5 tons16,700 Btu/h · Ducted2.7572%8.015.5CEE 25CEE 26XcelES CC251214391623
3037RP15AZ24AJ2NRHEEMwith indoor coil D(A,C,E)36D24+TDR and furnace R801V1004A17UHNRheem2 tons22,200 Btu/h · Ducted3.1571%8.516.3CEE 25CEE 26XcelES CC308214802736
3038RP15AZ30AJ2NRUUDwith indoor coil CP31A34+TDR and furnace U802VA075317MRheem2.5 tons27,000 Btu/h · Ducted2.7171%8.015.3CEE 25CEE 26XcelES CC454214391790
3039RP15AZ36AJ2NRUUDwith indoor coil CP37A34+TDR and furnace R802V1005A21UHNRheem2.5 tons32,800 Btu/h · Ducted2.8575%8.015.3XcelES CC276214391832
3040RP15AZ42AJ2NRHEEMwith indoor coil D(A,C,E)60D34+TDR and furnace R801V0754A17DZRheem3.5 tons39,000 Btu/h · Ducted3.1174%7.714.6XcelES CC730214802795
3041RP15AZ48AJ2NRUUDwith indoor coil CP61B34+TDR and furnace ROCB118V05MRheem3.5 tons44,500 Btu/h · Ducted3.1878%7.614.6CEE 25CEE 26XcelES CC803214392040
3042RP1724HJVXARHEEMwith ductless indoor unit RICH24AXCJRheem2 tons24,000 Btu/h · Ducted and non-ducted2.0497%10.120.8CEE 25CEE 26Xcel5210839352
3043RP1736HJVXARHEEMwith ducted air handler RHMV3621MNACRheem3 tons36,000 Btu/h · Ducted2.0278%——CEE 25CEE 26Xcel3206137898
3044RP18AZ24AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ2421HEAAM and furnace R802V1004A17UHSRheem2 tons22,800 Btu/h · Ducted2.10108%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC28212609307
3045RP18AZ36AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ6021SEAAM and furnace R802VA075317MRheem3 tons34,200 Btu/h · Ducted2.20119%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC34210589387
3046RP18AZ48AJVCRHEEM · PRESTIGE SERIESwith ducted air handler RHMVZ6021SEACARheem4 tons45,000 Btu/h · Ducted2.0088%8.519.0CEE 25CEE 26XcelES CC25208552859
3047RP18AZ60AJVCRHEEMwith indoor coil RCFZ6021SEAAM and furnace R962V0705A21M4SRheem4.5 tons52,500 Btu/h · Ducted2.0096%8.118.0Xcel15209872733
3048SP18AZ24AJVCSURE · VANTIXwith indoor coil TCFZ2421HEAAM and furnace S802V0754A17UHNRheem2 tons22,800 Btu/h · Ducted2.10108%8.519.0CEE 25CEE 26CEE AdvXcelDOEES CC27212609310
3049SP18AZ36AJVCSURE · VANTIXwith ducted air handler SHMVZ6021SEACARheem3 tons34,200 Btu/h · Ducted2.20121%8.518.0CEE 25CEE 26CEE AdvXcelDOEES CC30210106714
3050SP18AZ48AJVCSUREwith indoor coil TCFZ6021SEAAM and furnace S962V0705A21M4SRheem3.5 tons44,000 Btu/h · Ducted2.00103%8.118.0CEE 25CEE 26XcelES CC22210106775

Explore qualifying models by COP at 5°F