Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
Simple view, for homeowners: top picks by size and what each rating measures →
Xcel EnergyData as of updated · sources
- Share of models
- 38.1%
- Qualifying models
- 3,739
- Qualifying certifications
- 83,510
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 37 |
| 1.40 to under 1.50 | 124 |
| 1.50 to under 1.60 | 87 |
| 1.60 to under 1.70 | 118 |
| 1.70 to under 1.80 | 916 |
| 1.80 to under 1.90 | 2,176 |
| 1.90 to under 2.00 | 1,272 |
| 2.00 to under 2.10 | 1,285 |
| 2.10 to under 2.20 | 613 |
| 2.20 to under 2.30 | 484 |
| 2.30 to under 2.40 | 356 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 114 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.91 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 68 |
| 35 to under 40% | 378 |
| 40 to under 45% | 216 |
| 45 to under 50% | 320 |
| 50 to under 55% | 640 |
| 55 to under 60% | 790 |
| 60 to under 65% | 964 |
| 65 to under 70% | 885 |
| 70 to under 75% | 1,102 |
| 75 to under 80% | 505 |
| 80 to under 85% | 543 |
| 85 to under 90% | 414 |
| 90 to under 95% | 386 |
| 95 to under 100% | 274 |
| 100 to under 105% | 389 |
| 105 to under 110% | 73 |
| 110 to under 115% | 81 |
| 115 to under 120% | 28 |
| 120 to under 125% | 46 |
| 125 to under 130% | 12 |
| 130% and above | 32 |
| Baseline: median | 69% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 678 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 574 |
| 14.5 to under 15.0 | 326 |
| 15.0 to under 15.5 | 991 |
| 15.5 to under 16.0 | 357 |
| 16.0 to under 16.5 | 727 |
| 16.5 to under 17.0 | 303 |
| 17.0 to under 17.5 | 525 |
| 17.5 to under 18.0 | 332 |
| 18.0 to under 18.5 | 382 |
| 18.5 to under 19.0 | 284 |
| 19.0 to under 19.5 | 609 |
| 19.5 to under 20.0 | 172 |
| 20.0 to under 20.5 | 494 |
| 20.5 to under 21.0 | 260 |
| 21.0 to under 21.5 | 544 |
| 21.5 to under 22.0 | 330 |
| 22.0 to under 22.5 | 342 |
| 22.5 to under 23.0 | 183 |
| 23.0 to under 23.5 | 302 |
| 23.5 to under 24.0 | 168 |
| 24.0 to under 24.5 | 111 |
| 24.5 to under 25.0 | 56 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 55 |
| 26.0 to under 26.5 | 50 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 32 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 247 |
| 8.5 to under 9.0 | 608 |
| 9.0 to under 9.5 | 525 |
| 9.5 to under 10.0 | 392 |
| 10.0 to under 10.5 | 896 |
| 10.5 to under 11.0 | 1,192 |
| 11.0 to under 11.5 | 995 |
| 11.5 to under 12.0 | 1,102 |
| 12.0 to under 12.5 | 944 |
| 12.5 to under 13.0 | 1,269 |
| 13.0 to under 13.5 | 576 |
| 13.5 to under 14.0 | 231 |
| 14.0 to under 14.5 | 128 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 97 |
| 15.5 to under 16.0 | 78 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 34 |
| Baseline: median | 11.3 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons54.6% · 1,748 of 3,201
- 2 tons46.9% · 682 of 1,454
- 2.5 to 3 tons31.5% · 830 of 2,633
- 3.5 to 4.5 tons20.7% · 449 of 2,174
- 5 tons and up8.3% · 30 of 362
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 54.6% · 1,748 of 3,201 |
| 2 tons | 46.9% · 682 of 1,454 |
| 2.5 to 3 tons | 31.5% · 830 of 2,633 |
| 3.5 to 4.5 tons | 20.7% · 449 of 2,174 |
| 5 tons and up | 8.3% · 30 of 362 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 21.1% | 970 / 4,608 |
| Non-ducted | 43.5% | 1,444 / 3,317 |
| Ducted and non-ducted | 69.8% | 1,325 / 1,899 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 242 of 403 | 60% |
| Mitsubishi Electric | 206 of 400 | 51.5% |
| Midea | 184 of 408 | 45.1% |
| Lennox | 124 of 375 | 33.1% |
| Carrier | 120 of 701 | 17.1% |
| Rheem | 102 of 291 | 35.1% |
| Hisense | 101 of 160 | 63.1% |
| Trane | 68 of 309 | 22% |
| Fujitsu | 56 of 164 | 34.1% |
| Daikin | 55 of 371 | 14.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 3076ROSH09AFFHJRHEEMwith ductless indoor unit RIFH09AVFJ | Rheem | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 112% | 11.6 | 26.0 | CEE 25CEE 26Xcel | 2 | 10595383 |
| 3077ROSH09AFFJRHEEMwith ductless indoor unit RIFH09AVFJ | Rheem | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 112% | 11.8 | 26.0 | CEE 25CEE 26Xcel | 2 | 10595392 |
| 3078ROSH12AFFHJRHEEMwith ductless indoor unit RIFH12AVFJ | Rheem | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 84% | 11.0 | 22.7 | CEE 25CEE 26Xcel | 2 | 10595386 |
| 3079ROSH12AFFJRHEEMwith ductless indoor unit RIFH12AVFJ | Rheem | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 84% | 11.2 | 22.7 | CEE 25CEE 26Xcel | 2 | 10595394 |
| 3080ROSH15AFFHJRHEEMwith ductless indoor unit RIFH15AVFJ | Rheem | 1 ton14,200 Btu/h · Non-ducted | 1.84 | 101% | 10.5 | 20.3 | CEE 25CEE 26Xcel | 2 | 10595389 |
| 3081ROSH15AFFJRHEEMwith ductless indoor unit RIFH15AVFJ | Rheem | 1 ton14,200 Btu/h · Non-ducted | 1.84 | 101% | 10.7 | 20.3 | CEE 25CEE 26Xcel | 2 | 10595396 |
| 3082ROSH18AHXHJRHEEMwith ductless indoor unit RIWH18AVFJ | Rheem | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 88% | 10.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 10595377 |
| 3083ROSH18VGSNRHEEMwith ductless indoor unit RICH18AXCJ | Rheem | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.32 | 86% | 10.5 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 4 | 202244046 |
| 3084ROSH24AHXHJRHEEMwith ductless indoor unit RIWH24AVFJ | Rheem | 2 tons22,000 Btu/h · Non-ducted | 2.04 | 92% | 10.5 | 19.5 | CEE 25CEE 26Xcel | 2 | 10595379 |
| 3085ROSH24VGSNRHEEMwith ductless indoor unit RICH24AXCJ | Rheem | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.04 | 86% | 10.1 | 20.8 | CEE 25CEE 26Xcel | 4 | 202244731 |
| 3086ROSH30AHXHJRHEEMwith ductless indoor unit RIWH30AVFJ | Rheem | 2.5 tons30,000 Btu/h · Non-ducted | 2.02 | 95% | 10.0 | 18.7 | CEE 25CEE 26Xcel | 2 | 10595381 |
| 3087ROSH30VGSNRHEEMwith ductless indoor unit RICH30AXCJ | Rheem | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.30 | 81% | 10.4 | 18.7 | CEE 25CEE 26Xcel | 4 | 202245032 |
| 3088ROSH36VGSNRHEEMwith ductless indoor unit RICH36AXCJ | Rheem | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.32 | 74% | 9.7 | 18.0 | CEE 25CEE 26Xcel | 4 | 202245794 |
| 3089ROSH42VGSNRHEEMwith ductless indoor unit RICH42AXCJ | Rheem | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.28 | 81% | 9.8 | 19.0 | CEE 25CEE 26Xcel | 4 | 202245810 |
| 3090ROSH48VGSNRHEEMwith ducted air handler RIDH48AXCJ | Rheem | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.22 | 75% | 9.0 | 16.4 | CEE 25CEE 26Xcel | 4 | 207590037 |
| 3091RP15AZ18AJ2NRUUDwith indoor coil CP31A34+TDR and furnace R921V0603A17M4S | Rheem | 1.5 tons16,700 Btu/h · Ducted | 2.75 | 72% | 8.0 | 15.5 | CEE 25CEE 26XcelES CC | 251 | 214391623 |
| 3092RP15AZ24AJ2NRHEEMwith indoor coil D(A,C,E)36D24+TDR and furnace R801V1004A17UHN | Rheem | 2 tons22,200 Btu/h · Ducted | 3.15 | 71% | 8.5 | 16.3 | CEE 25CEE 26XcelES CC | 308 | 214802736 |
| 3093RP15AZ30AJ2NRUUDwith indoor coil CP31A34+TDR and furnace U802VA075317M | Rheem | 2.5 tons27,000 Btu/h · Ducted | 2.71 | 71% | 8.0 | 15.3 | CEE 25CEE 26XcelES CC | 454 | 214391790 |
| 3094RP15AZ36AJ2NRUUDwith indoor coil CP37A34+TDR and furnace R802V1005A21UHN | Rheem | 2.5 tons32,800 Btu/h · Ducted | 2.85 | 75% | 8.0 | 15.3 | XcelES CC | 276 | 214391832 |
| 3095RP15AZ42AJ2NRHEEMwith indoor coil D(A,C,E)60D34+TDR and furnace R801V0754A17DZ | Rheem | 3.5 tons39,000 Btu/h · Ducted | 3.11 | 74% | 7.7 | 14.6 | XcelES CC | 730 | 214802795 |
| 3096RP15AZ48AJ2NRUUDwith indoor coil CP61B34+TDR and furnace ROCB118V05M | Rheem | 3.5 tons44,500 Btu/h · Ducted | 3.18 | 78% | 7.6 | 14.6 | CEE 25CEE 26XcelES CC | 803 | 214392040 |
| 3097RP1724HJVXARHEEMwith ductless indoor unit RICH24AXCJ | Rheem | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.04 | 97% | 10.1 | 20.8 | CEE 25CEE 26Xcel | 5 | 210839352 |
| 3098RP1736HJVXARHEEMwith ducted air handler RHMV3621MNAC | Rheem | 3 tons36,000 Btu/h · Ducted | 2.02 | 78% | — | — | CEE 25CEE 26Xcel | 3 | 206137898 |
| 3099RP18AZ24AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ2421HEAAM and furnace R802V1004A17UHS | Rheem | 2 tons22,800 Btu/h · Ducted | 2.10 | 108% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 28 | 212609307 |
| 3100RP18AZ36AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ6021SEAAM and furnace R802VA075317M | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 119% | 8.5 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 34 | 210589387 |