Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 126 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
3126RD17AZ36AJ3NRUSSELLwith ducted air handler RF2TZ3624STANSRUSSELL2.5 tons32,400 Btu/h · Ducted2.4058%8.117.0CEE 25CEE 26XcelES CC111214100072
3127RD17AZ48AJ3NRUSSELLwith indoor coil TCFZ6024STANM and furnace S802V1005A21UHSRUSSELL4 tons45,500 Btu/h · Ducted2.4056%8.116.0CEE 25CEE 26XcelES CC98214075619
3128RD17AZ60AJ3NRUSSELLwith ducted air handler SH2VZ6024STANNRUSSELL4.5 tons55,500 Btu/h · Ducted2.2050%8.116.0XcelES CC53214075182
3129SP18AZ24AJVCRUSSELL · VANTIXwith indoor coil TCFZ2421HEAAM and furnace S802V0504A17UHSRUSSELL2 tons22,800 Btu/h · Ducted2.10108%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC27212609309
3130SP18AZ36AJVCRUSSELL · VANTIXwith ducted air handler SHMVZ6021SEACARUSSELL3 tons34,200 Btu/h · Ducted2.20121%8.518.0CEE 25CEE 26CEE AdvXcelDOEES CC30210106900
3131SP18AZ48AJVCRUSSELLwith indoor coil TCFZ6021SEAAM and furnace S962V0705A21M4SRUSSELL3.5 tons44,000 Btu/h · Ducted2.00103%8.118.0CEE 25CEE 26XcelES CC22210106962
3132SP18AZ60AJVCRUSSELLwith indoor coil TCFZ6021SEAAM and furnace S962V0705A21M4SRUSSELL4.5 tons52,500 Btu/h · Ducted2.0096%8.118.0CEE 25CEE 26Xcel15210106984
3133AC009BXADCHSAMSUNG · Mini 4-Way Cassette (WindFree™)with ductless indoor unit AC009BNNDCHSamsung1 ton9,100 Btu/h · Ducted and non-ducted1.89121%9.522.0CEE 25CEE 26Xcel5207462387
3134AC012BXADCHSAMSUNG · Slim Duct (LSP)with ducted air handler AC012BNLDCHSamsung1 ton12,000 Btu/h · Ducted and non-ducted1.9582%9.219.0CEE 25CEE 26Xcel5207465443
3135AC018BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC018BN4DCHSamsung1.5 tons18,000 Btu/h · Ducted and non-ducted1.92146%8.523.6CEE 25CEE 26Xcel9207462388
3136AC024BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC024BN4DCHSamsung2 tons24,000 Btu/h · Ducted and non-ducted1.83104%8.621.0CEE 25CEE 26Xcel5207462389
3137AC024BXUPCHSAMSUNGwith ducted air handler AFM354+TDRSamsung2 tons23,800 Btu/h · Ducted2.10119%8.116.5XcelES CC4212150566
3138AC030BXADCHSAMSUNG · Duct S (HSP)with ducted air handler AC030BNHDCHSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted1.9397%8.418.2CEE 25CEE 26Xcel5207465458
3139AC030BXSCCHSAMSUNG · 4-Way Cassette (WindFree™) Max Heatwith ductless indoor unit AC030BN4DCHSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted2.03114%8.922.6CEE 25CEE 26Xcel3207698065
3140AC036BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC036BN4DCHSamsung3 tons36,000 Btu/h · Ducted and non-ducted2.17103%8.820.5CEE 25CEE 26CEE AdvXcelDOE5207462390
3141AC036BXSCCHSAMSUNG · 4-Way Cassette (WindFree™) Max Heatwith ductless indoor unit AC036BN4DCHSamsung3 tons36,000 Btu/h · Ducted and non-ducted2.12107%9.121.6CEE 25CEE 26CEE AdvXcelDOE3207698071
3142AC036BXUPCHSAMSUNGwith ducted air handler L(E,G)M36G4Samsung3 tons35,800 Btu/h · Ducted2.26117%8.418.5XcelES CC7212590506
3143AC042BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC042BN4DCHSamsung3.5 tons42,000 Btu/h · Ducted and non-ducted1.98104%8.719.1CEE 25CEE 26Xcel4207462391
3144AJ020BXJ2CHSAMSUNG · FJMSamsung1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7670%8.619.5CEE 25CEE 26Xcel3207349914
3145AJ020BXS3CHSAMSUNG · FJM Max HeatSamsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95100%9.019.0CEE 25CEE 26Xcel3207349917
3146AJ020CXS3CHSAMSUNG · FJM Max HeatSamsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95105%10.523.0CEE 25CEE 26Xcel3213353367
3147AJ024BXS4CHSAMSUNG · FJM Max HeatSamsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.0CEE 25CEE 26Xcel3207349918
3148AJ024CXS4CHSAMSUNG · FJM Max HeatSamsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.85100%10.423.0CEE 25CEE 26Xcel3213353368
3149AJ030BXS4CHSAMSUNG · FJM Max HeatSamsung2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%9.020.0CEE 25CEE 26Xcel3207349919
3150AJ030CXS4CHSAMSUNG · FJM Max HeatSamsung2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.81101%10.422.5CEE 25CEE 26Xcel3213353369

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter