Xcel Energy Colorado cold-climate ASHP (2025): 3,624 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
New to heat pump ratings? The Simple view explains them in plain words →
Xcel EnergyData as of updated · sources
- Share of models
- 37.6%
- Qualifying models
- 3,624
- Qualifying certifications
- 83,159
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,084 |
| 1.90 to under 2.00 | 1,248 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 469 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 529 |
| 85 to under 90% | 414 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 658 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 986 |
| 15.5 to under 16.0 | 347 |
| 16.0 to under 16.5 | 714 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 370 |
| 18.5 to under 19.0 | 277 |
| 19.0 to under 19.5 | 590 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 387 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,155 |
| 11.0 to under 11.5 | 964 |
| 11.5 to under 12.0 | 1,095 |
| 12.0 to under 12.5 | 908 |
| 12.5 to under 13.0 | 1,265 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons54.1% · 1,693 of 3,129
- 2 tons46.3% · 665 of 1,436
- 2.5–3 tons31.3% · 809 of 2,587
- 3.5–4.5 tons20.1% · 429 of 2,136
- 5 tons and up8% · 28 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 54.1% · 1,693 of 3,129 |
| 2 tons | 46.3% · 665 of 1,436 |
| 2.5–3 tons | 31.3% · 809 of 2,587 |
| 3.5–4.5 tons | 20.1% · 429 of 2,136 |
| 5 tons and up | 8% · 28 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 20.5% | 931 / 4,546 |
| Non-ducted | 43.1% | 1,394 / 3,236 |
| Ducted and non-ducted | 70% | 1,299 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 223 of 395 | 56.5% |
| Mitsubishi Electric | 200 of 373 | 53.6% |
| Midea | 180 of 402 | 44.8% |
| Carrier | 120 of 701 | 17.1% |
| Rheem | 102 of 291 | 35.1% |
| Hisense | 94 of 159 | 59.1% |
| Lennox | 92 of 313 | 29.4% |
| Trane | 68 of 309 | 22% |
| Fujitsu | 56 of 164 | 34.1% |
| Daikin | 55 of 367 | 15% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 3251TSM5OA55HFN1M[X]TEMP SHIFT | TEMP SHIFT | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.77 | 85% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 3 | 213479401 |
| 3252TSM5OG48HFN1M[X]TEMP SHIFT | TEMP SHIFT | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 92% | 10.0 | 21.2 | CEE 25CEE 26Xcel | 3 | 213479398 |
| 3253TSMOD3024HFN1MU0WTEMP SHIFTwith ductless indoor unit TSMCD124HRFN1MT0W(GA) | TEMP SHIFT | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.00 | 103% | 11.5 | 20.5 | CEE 25CEE 26Xcel | 3 | 213479382 |
| 3254TSMOD3024HFN1MWTEMP SHIFTwith ducted air handler TSMAC24HWDN1MN0 | TEMP SHIFT | 2 tons24,000 Btu/h · Ducted | 1.95 | 80% | 9.5 | 16.5 | CEE 25CEE 26Xcel | 2 | 212925581 |
| 3255TSMOD30U30HFN1MR0(X)TEMP SHIFTwith ducted air handler TSMAC36HWDN1MN0 | TEMP SHIFT | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26Xcel | 3 | 212925582 |
| 3256TSMOE30U36HFN1M(GA)TEMP SHIFTwith ductless indoor unit TSMCD136HRFN1M(GA) | TEMP SHIFT | 3 tons36,000 Btu/h · Non-ducted | 1.83 | 103% | 10.5 | 19.4 | Xcel | 1 | 213479383 |
| 3257TSMOE30U55HFN1MTEMP SHIFTwith ducted air handler TSMVC60HWFN1M | TEMP SHIFT | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | Xcel | 3 | 212925597 |
| 3258TSMOE31U36HFN1MTEMP SHIFTwith ducted air handler TSMAC36HWDN1MN0 | TEMP SHIFT | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26Xcel | 3 | 212925583 |
| 3259TSMOX23009HFN1MW5WTEMP SHIFTwith ductless indoor unit TSMSAG11A06HRFN1MU0W | TEMP SHIFT | 0.5 tons6,000 Btu/h · Non-ducted | 1.84 | 101% | 12.0 | 23.5 | CEE 25CEE 26Xcel | 1 | 216014855 |
| 3260TSMOX33009HFN1MY5WTEMP SHIFTwith ducted air handler TSMTIU09HWFN1M | TEMP SHIFT | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.90 | 108% | 12.0 | 20.2 | CEE 25CEE 26Xcel | 3 | 213479385 |
| 3261TSMOX33012HFN1MW5WTEMP SHIFTwith ducted air handler TSMTIU12HWFN1M | TEMP SHIFT | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.96 | 97% | 10.0 | 19.5 | CEE 25CEE 26Xcel | 3 | 213479386 |
| 3262TSMOX43017HFN1MT0WTEMP SHIFTwith ductless indoor unit TSMSAG11D18HRFN1MT8W | TEMP SHIFT | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 1.89 | 96% | 10.6 | 22.0 | CEE 25CEE 26Xcel | 3 | 216014858 |
| 3263TSMOX430U18HFN1MTEMP SHIFTwith ducted air handler TSMAC24HWDN1MN0 | TEMP SHIFT | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26Xcel | 2 | 212925580 |
| 3264TSMOX430U24HFN1MR0TEMP SHIFTwith ducted air handler TSMAC24HWDN1MN0 | TEMP SHIFT | 2 tons24,000 Btu/h · Ducted | 2.20 | 72% | 9.8 | 15.7 | CEE 25CEE 26Xcel | 2 | 212925575 |
| 3265TSMOX63036HFN1M3XTEMP SHIFTwith ducted air handler TSMVB36B24T4N1 | TEMP SHIFT | 3 tons35,000 Btu/h · Ducted | 1.80 | 83% | 8.5 | 15.2 | CEE 25CEE 26Xcel | 3 | 213479377 |
| 3266TEXAN018HHCU1TEXANAIRwith ducted air handler TEXANWM18A1 | TEXANAIR | 1.5 tons18,000 Btu/h · Ducted | 2.30 | 99% | 10.8 | 19.3 | CEE 25CEE 26Xcel | 3 | 214648704 |
| 3267TEXAN024HHCU1TEXANAIRwith ducted air handler TEXANDF24B1 | TEXANAIR | 1.5 tons20,000 Btu/h · Ducted | 2.00 | 80% | 10.2 | 16.3 | CEE 25CEE 26Xcel | 4 | 214648691 |
| 3268TEXAN024STCU1TEXANAIRwith ducted air handler TEXANWM24A1 | TEXANAIR | 2 tons24,000 Btu/h · Ducted | 2.33 | 75% | 10.2 | 17.0 | CEE 25CEE 26Xcel | 4 | 214648701 |
| 3269TEXAN030HHCU1TEXANAIRwith ducted air handler TEXANDF36A1 | TEXANAIR | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26Xcel | 4 | 214648694 |
| 3270TEXAN036HHCU1TEXANAIRwith ducted air handler TEXANDF36A1 | TEXANAIR | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26Xcel | 4 | 214648696 |
| 3271TEXAN036HHCU2TEXANAIRwith ducted air handler TEXAN036AHU1 | TEXANAIR | 3 tons35,000 Btu/h · Ducted | 1.80 | 97% | 9.5 | 16.3 | CEE 25CEE 26Xcel | 3 | 214648678 |
| 3272TEXAN060HHCU1TEXANAIRwith ducted air handler TEXAN060AHU1 | TEXANAIR | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | Xcel | 2 | 214648680 |
| 3273GRHART36AS3TGMwith ductless indoor unit GWHART36S3 | TGM | 3 tons33,600 Btu/h · Non-ducted | 1.85 | 71% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 210605768 |
| 3274GTS18HN036ATGM · Flexxwith ducted air handler GTA18H024A | TGM | 2 tons24,000 Btu/h · Ducted | 1.80 | 92% | 9.0 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 210627720 |