Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 138 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
34264TWV8X60A1TRANEwith indoor coil D(A,C,E)60B44+TDR and furnace S9V2C080U5PSC+RPTrane4 tons50,500 Btu/h · Ducted2.10115%7.918.0CEE 25CEE 26XcelES CC132215472309
34274TXD2036A10NU**TRANEwith ducted air handler F,PE*E32930Trane2 tons23,000 Btu/h · Ducted2.10107%8.916.0CEE 25CEE 26CEE AdvXcelDOEES CC65212396546
34284TXD2060A10NU**TRANEwith ducted air handler C(A,C,D,E)48C44+TDRTrane4 tons47,000 Btu/h · Ducted1.8872%8.515.2CEE 25CEE 26XcelES CC34214056972
34294TXK1709A10N0**TRANEwith ductless indoor unit 4MXW1709A10N0Trane1 ton9,000 Btu/h · Non-ducted1.7679%8.417.5Xcel2208130224
34304TXK2509A10N0**TRANEwith ductless indoor unit 4MXD2309A10N0Trane1 ton9,100 Btu/h · Non-ducted1.9362%9.520.4CEE 25CEE 26Xcel6212292414
34314TXK2512A10N0**TRANE · 25 Serieswith ductless indoor unit 4MXW2512A10N0Trane1 ton12,000 Btu/h · Non-ducted1.9377%9.025.0CEE 25CEE 26Xcel6207629149
34324TXK2518A10N0**TRANEwith ductless indoor unit 4MXW2518A10N0Trane1.5 tons18,000 Btu/h · Ducted and non-ducted1.7980%8.523.0CEE 25CEE 26Xcel6207642981
34334TXK2524A10N0**AMERICAN STANDARDwith ductless indoor unit 4MXD2324A10N0Trane2 tons22,000 Btu/h · Non-ducted1.9079%9.020.0CEE 25CEE 26XcelES CC8211727035
34344TXK3809B10NU**TRANE · 38 Serieswith ductless indoor unit 4MXW3809B10NUTrane1 ton9,000 Btu/h · Non-ducted1.91144%11.027.0CEE 25CEE 26XcelES CC2204340354
34354TXK3812A10NU**TRANE · 38 Serieswith ductless indoor unit 4MXW3812A10NUTrane1 ton12,000 Btu/h · Non-ducted1.9198%8.524.0CEE 25CEE 26XcelES CC29150123
34364TXK3818A10NU**TRANE · 38 Serieswith ductless indoor unit 4MXW3818A10NUTrane1.5 tons18,000 Btu/h · Non-ducted1.80111%10.022.0CEE 25CEE 26XcelES CC29150125
34374TXM2118A12N0**TRANE · M-SeriesTrane1.5 tons17,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2176%10.021.0CEE 25CEE 26XcelES CC6210435405
34384TXM2124A13N0**TRANE · M-SeriesTrane2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.0CEE 25CEE 26XcelES CC6210435406
34394TXM2130A14N0**TRANE · M-SeriesTrane2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8476%10.021.0CEE 25CEE 26XcelES CC6210435407
34404TXM2136A14N0**TRANE · M-SeriesTrane3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8290%10.021.0CEE 25CEE 26XcelES CC6210435408
34414TXM2142A15N0**TRANE · M-SeriesTrane3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9281%10.021.0CEE 25CEE 26XcelES CC6210435409
34424TXM2318A12NU**TRANE · 23 MZ SeriesTrane1.5 tons18,000 Btu/h · Non-ducted1.81104%10.020.0CEE 25CEE 26XcelES CC2204340534
34434TXM2324A13NU**TRANE · 23 MZ SeriesTrane2 tons22,000 Btu/h · Non-ducted1.80115%10.020.0CEE 25CEE 26Xcel2204340536
34444TXM2330A14NU**TRANE · 23 MZ SeriesTrane3 tons36,000 Btu/h · Non-ducted and mixed (multi-zone)1.8278%8.616.0XcelES CC4206221558
34454TXM2336A15NU**TRANE · 23 MZ SeriesTrane3.5 tons42,000 Btu/h · Non-ducted and mixed (multi-zone)1.8274%8.616.0XcelES CC4206319651
3446A4HP4018D1AMERISTARwith ducted air handler L(E,G)M36L4Trane1.5 tons17,200 Btu/h · Ducted2.7974%7.514.3Xcel509214331620
3447A4HP5018D1RUNTRUwith ducted air handler PE(S,T)344Trane1.5 tons18,000 Btu/h · Ducted2.7280%7.514.3Xcel489212619898
3448E4HL5030A1000ARUNTRUwith ducted air handler A4AH5V30A1B3 + DFTrane2.5 tons28,000 Btu/h · Ducted1.9075%8.515.2XcelES CC44213894041
3449E4HL5036A1000ATRANEwith ducted air handler E4AH5E24A1J30ATrane2 tons24,000 Btu/h · Ducted1.9075%8.515.2XcelES CC102214608245
3450E4HL5042A1000ARUNTRU · E4HL5with ducted air handler E4AH5E36A1J30ATrane3 tons36,000 Btu/h · Ducted1.8092%8.515.2Xcel31212617024

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy