Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 144 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
3576WMCA-18HFMOWells · WSA SeriesWells1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.5CEE 25CEE 26XcelES CC3213286775
3577WMCA-27HFMOWells · WMA SeriesWells2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.90101%10.019.0CEE 25CEE 26XcelES CC3213286779
3578WMCA-36HFMOWells · WSA SeriesWells3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95100%10.921.0CEE 25CEE 26XcelES CC3213307896
3579WMCA-48HFMOWells · VMC SeriesWells4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%10.021.2CEE 25CEE 26XcelES CC3213286781
3580WMCA-55HFMOWells · WSA SeriesWells4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.520.0CEE 25CEE 26XcelES CC3213286784
3581WMMA-18HFMOWells · WSA SeriesWells1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.221.0CEE 25CEE 26XcelES CC3213286760
3582WMMA-27HFMOWells · WSA SeriesWells2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.223.5CEE 25CEE 26Xcel3213286763
3583WRPA-36HDM/TCWELLS · RooftopWells3 tons34,400 Btu/h · Ducted1.7572%8.817.8CEE 25CEE 26Xcel1214432067
3584WRPA-60HDM/TCWELLS · RooftopWells4.5 tons56,000 Btu/h · Ducted1.8079%8.317.0XcelES CC1214432066
3585WSA-06HFMOWells · WSA Serieswith ductless indoor unit WSA-06HFMIWells0.5 tons6,000 Btu/h · Non-ducted1.84101%12.023.5CEE 25CEE 26XcelES CC1214421468
3586WSA-09HFMOWells · WSA Serieswith ductless indoor unit WSA-09HFMIWells1 ton9,000 Btu/h · Non-ducted1.9094%11.626.4CEE 25CEE 26XcelES CC1214421469
3587WSA-12HFMOWells · WSA Serieswith ductless indoor unit WSA-12HFMIWells1 ton12,000 Btu/h · Non-ducted1.8992%10.523.1CEE 25CEE 26XcelES CC1214421470
3588WSA-18HFMOWells · WSA Serieswith ductless indoor unit WSA-18HFMIWells1.5 tons18,000 Btu/h · Non-ducted1.8996%10.622.0CEE 25CEE 26XcelES CC1214421471
3589WSA-24HFMOWells · WSA Serieswith ductless indoor unit WSA-24HFMIWells2 tons23,000 Btu/h · Non-ducted1.8088%10.322.3CEE 25CEE 26XcelES CC1214421472
3590WSA-33HFMOWells · WSA Serieswith ductless indoor unit WSA-33HFMIWells3 tons33,000 Btu/h · Non-ducted1.8099%10.020.0CEE 25CEE 26XcelES CC1214421473
3591WSB-09HFBOWells · WSB Serieswith ductless indoor unit WSB-09HFBIWells1 ton9,000 Btu/h · Non-ducted2.1670%9.121.5CEE 25CEE 26XcelES CC1214421460
3592WSB-09HFMOWells · WSB Serieswith ductless indoor unit WSB-09HFMIWells1 ton9,000 Btu/h · Non-ducted1.9970%9.421.7CEE 25CEE 26XcelES CC1214421462
3593WUCA-24HFMOWells · WUA Serieswith ducted air handler WUA-24AHFMWells2 tons24,000 Btu/h · Ducted2.0080%9.816.1CEE 25CEE 26XcelES CC2213363381
3594WUCA-30HFMOWells · WUA Serieswith ducted air handler WUA-36CHFMWells2.5 tons30,000 Btu/h · Ducted1.8582%9.715.5CEE 25CEE 26XcelES CC5214489061
3595WUCA-36HFMOWells · WUA Serieswith ducted air handler WUA-36CHFMWells3 tons35,000 Btu/h · Ducted2.0082%10.015.2CEE 25CEE 26XcelES CC5214489062
3596WUCB-36HFMOWells · WUA Serieswith ducted air handler WUA-36HFMAHWells3 tons35,000 Btu/h · Ducted1.8097%9.516.3CEE 25CEE 26XcelES CC5213927635
3597CHW09KCH20S2-OWILLISwith ductless indoor unit CHW09KCH20S2-IWILLIS1 ton9,100 Btu/h · Non-ducted1.7775%8.819.5CEE 25CEE 26Xcel1214609734
3598FLEX24/36KUHWillis · FLEXX High-efficiency Serieswith ducted air handler FLEXAH24/36KWILLIS3 tons34,000 Btu/h · Ducted1.8080%9.016.0CEE 25CEE 26XcelES CC3214137765
3599FLEX48/60KUHWillis · FLEXX High-efficiency Serieswith ducted air handler FLEXAH48/60KWILLIS4.5 tons54,000 Btu/h · Ducted1.8076%9.016.0CEE 25CEE 26XcelES CC3214797686
3600HW12KUHR410A-OWilliswith ductless indoor unit HW12KUHR410A-IWILLIS1 ton12,000 Btu/h · Non-ducted2.0570%9.523.5CEE 25CEE 26Xcel1216772615

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter