Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel Energy Colorado cold-climate ASHP (2025): 3,627 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
New to heat pump ratings? The Simple view explains them in plain words →
Xcel EnergyData as of updated · sources
- Share of models
- 37.6%
- Qualifying models
- 3,627
- Qualifying certifications
- 83,155
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,085 |
| 1.90 to under 2.00 | 1,249 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 470 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 531 |
| 85 to under 90% | 415 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 658 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 987 |
| 15.5 to under 16.0 | 347 |
| 16.0 to under 16.5 | 716 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 370 |
| 18.5 to under 19.0 | 277 |
| 19.0 to under 19.5 | 590 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 388 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,156 |
| 11.0 to under 11.5 | 964 |
| 11.5 to under 12.0 | 1,096 |
| 12.0 to under 12.5 | 908 |
| 12.5 to under 13.0 | 1,265 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons54.1% · 1,694 of 3,130
- 2 tons46.3% · 666 of 1,437
- 2.5–3 tons31.3% · 810 of 2,588
- 3.5–4.5 tons20.1% · 429 of 2,136
- 5 tons and up8% · 28 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 54.1% · 1,694 of 3,130 |
| 2 tons | 46.3% · 666 of 1,437 |
| 2.5–3 tons | 31.3% · 810 of 2,588 |
| 3.5–4.5 tons | 20.1% · 429 of 2,136 |
| 5 tons and up | 8% · 28 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 20.5% | 934 / 4,549 |
| Non-ducted | 43.1% | 1,394 / 3,236 |
| Ducted and non-ducted | 70% | 1,299 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 223 of 395 | 56.5% |
| Mitsubishi Electric | 200 of 373 | 53.6% |
| Midea | 180 of 402 | 44.8% |
| Carrier | 120 of 701 | 17.1% |
| Rheem | 102 of 291 | 35.1% |
| Hisense | 94 of 159 | 59.1% |
| Lennox | 92 of 313 | 29.4% |
| Trane | 68 of 309 | 22% |
| Fujitsu | 56 of 164 | 34.1% |
| Daikin | 55 of 367 | 15% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 501CDH2018C21CanAir · CDH serieswith ducted air handler MAC-24HWDN1-MN0 | CanAir | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26XcelES CC | 2 | 211644141 |
| 502CDH2024C21CanAir · CDH serieswith ducted air handler MVBM-24A18T3N1 | CanAir | 1.5 tons20,000 Btu/h · Ducted | 2.00 | 80% | 10.2 | 16.3 | CEE 25CEE 26XcelES CC | 4 | 213479417 |
| 503CDH2030C21CanAir · CDH serieswith ducted air handler MAC-36HWFN1-M | CanAir | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26XcelES CC | 2 | 211644140 |
| 504CDH2036C21CanAir · CDH serieswith ducted air handler MAC-36HWFN1-M | CanAir | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26XcelES CC | 3 | 211644138 |
| 505CDH2036C22CanAir · CDH serieswith ducted air handler MVB-36B23T4N1 | CanAir | 3 tons35,000 Btu/h · Ducted | 1.80 | 83% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 3 | 213479414 |
| 506CDH2060C22CanAir · CDH serieswith ducted air handler CDH2060F21 | CanAir | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | XcelES CC | 4 | 210342131 |
| 507MOD30-24HFN1-MWCanAir · MAC serieswith ducted air handler MAC-24HWDN1-MN0 | CanAir | 2 tons24,000 Btu/h · Ducted | 1.95 | 80% | 9.5 | 16.5 | CEE 25CEE 26XcelES CC | 1 | 209550334 |
| 508MOD30U-30HFN1-MR0(X)CanAir · MAC serieswith ducted air handler MAC-36HWFN1-M | CanAir | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | XcelES CC | 1 | 209550335 |
| 509MOE31U-36HFN1-MCanAir · MAC serieswith ducted air handler MAC-36HWFN1-M | CanAir | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | XcelES CC | 1 | 209550336 |
| 510MOX430-24HFN1-MR0CanAir · MAC serieswith ducted air handler MAC-24HWDN1-MN0 | CanAir | 2 tons24,000 Btu/h · Ducted | 2.20 | 72% | 9.8 | 15.7 | XcelES CC | 1 | 209550328 |
| 511MOX430U-18HFN1-MCanAir · MAC serieswith ducted air handler MAC-24HWDN1-MN0 | CanAir | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26XcelES CC | 1 | 209550333 |
| 512(C,H,T)VH825GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716A | Carrier | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 476 | 204456506 |
| 513(C,H,T)VH825GKA3*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X43L21A*+WALLCON and furnace *95CSU0802120A | Carrier | 2 tons24,400 Btu/h · Ducted | 2.24 | 86% | 8.5 | 17.0 | CEE 25CEE 26Xcel | 759 | 210473103 |
| 514(C,H,T)VH837GKA**KENMORE · DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120A | Carrier | 2.5 tons31,800 Btu/h · Ducted | 2.10 | 83% | 7.5 | 17.0 | CEE 25CEE 26Xcel | 581 | 204299603 |
| 515(C,H,T)VH837GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122A | Carrier | 3 tons33,200 Btu/h · Ducted | 2.24 | 86% | 8.5 | 18.0 | CEE 25CEE 26Xcel | 598 | 210470537 |
| 516(C,H,T)VH848GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CSU0802120A | Carrier | 4 tons45,500 Btu/h · Ducted | 2.32 | 71% | 8.5 | 17.0 | CEE 25CEE 26Xcel | 200 | 206997601 |
| 51725SCA524A**30*CARRIERwith indoor coil D(A,C,E)30C44+TDR and furnace 59TP6C100V21**22 | Carrier | 2 tons23,800 Btu/h · Ducted | 3.04 | 75% | 7.6 | 15.5 | Xcel | 1,175 | 213754846 |
| 51825SCA536A**30*CARRIERwith indoor coil D(A,C,E)36C34+TDR and furnace 59TN6B100C21**22 | Carrier | 3 tons33,200 Btu/h · Ducted | 2.77 | 40% | 7.8 | 15.1 | Xcel | 1,568 | 213202227 |
| 51925SPA524A**30*CARRIERwith indoor coil D(A,C,E)30C44+TDR and furnace 58TP*A045V14**12 | Carrier | 2 tons23,200 Btu/h · Ducted | 3.12 | 62% | 7.6 | 15.2 | Xcel | 1,100 | 213202532 |
| 52025VNA424A*031*CARRIERwith indoor coil CAP**3721AL*+UI and furnace 58TN*A090C17**16 | Carrier | 2 tons24,200 Btu/h · Ducted | 2.58 | 74% | 11.0 | 21.5 | CEE 25CEE 26Xcel | 410 | 210533008 |
| 52125VNA436A*031*CARRIER · INFINITY 24 HP with GREENSPEED INTELLIGENCEwith ducted air handler FE4BNBD60L*+UI | Carrier | 3 tons34,800 Btu/h · Ducted | 2.08 | 70% | 9.0 | 21.0 | CEE 25CEE 26Xcel | 646 | 213361587 |
| 52225VNA448A*031*CARRIER · INFINITY 24 HP with GREENSPEED INTELLIGENCEwith ducted air handler FE4BNBD60L*+UI | Carrier | 4 tons46,000 Btu/h · Ducted | 2.48 | 78% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 224 | 213361591 |
| 52325VNA813A*030*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**2517AL*+UI and furnace 59TN6C040C14**10 | Carrier | 1 ton13,000 Btu/h · Ducted | 2.00 | 75% | 8.1 | 15.5 | Xcel | 10 | 213770461 |
| 52425VNA825A*031*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**2517AL*+UI and furnace 58TN*A090C17**16 | Carrier | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 517 | 204451207 |
| 52525VNA825A*032*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**4321AL*+UI and furnace 59CU5A080C21**20 | Carrier | 2 tons24,400 Btu/h · Ducted | 2.24 | 86% | 8.5 | 17.0 | CEE 25CEE 26Xcel | 759 | 210473094 |