Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,624 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.6%
Qualifying models
3,624
Qualifying certifications
83,159
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,755 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,084
1.90 to under 2.001,248
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30469
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,747 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%529
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,260 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5986
15.5 to under 16.0347
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,260 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0387
10.0 to under 10.5900
10.5 to under 11.01,155
11.0 to under 11.5964
11.5 to under 12.01,095
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,129
2 tons46.3% · 665 of 1,436
2.5–3 tons31.3% · 809 of 2,587
3.5–4.5 tons20.1% · 429 of 2,136
5 tons and up8% · 28 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.5%931 / 4,546
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,299 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Lennox92 of 31329.4%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 22 of 145
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
52625VNA837A*030*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CNPV*4221AL*+UI and furnace 58TN*A090C21**20Carrier2.5 tons31,800 Btu/h · Ducted2.1083%7.517.0CEE 25CEE 26Xcel591204299595
52725VNA837A*031*CARRIER · INFINITY 18VS HEAT PUMPwith indoor coil CAP**6124AL*+UI and furnace 59CU5A100C21**22Carrier3 tons33,200 Btu/h · Ducted2.0278%8.518.0CEE 25CEE 26Xcel608210470528
528284ANV024*0**B*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**3721AL*+UI and furnace 88*TA48090C17Carrier2 tons24,200 Btu/h · Ducted2.5874%11.021.5CEE 25CEE 26Xcel410210533009
529284ANV036*0**B*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION Extreme 24 HPwith ducted air handler FE4ANB006L+UICarrier3 tons34,800 Btu/h · Ducted2.0670%9.520.5CEE 25CEE 26XcelES CC613206790264
530284ANV048*0**B*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION Extreme 24 HPwith ducted air handler FE4BNBD60L*+UICarrier4 tons46,000 Btu/h · Ducted2.4878%9.522.0CEE 25CEE 26XcelES CC217213361592
531288BNV013*0**A*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION V Heat Pumpwith indoor coil CAP**2517AL*+UI and furnace 986TD30040C14Carrier1 ton13,000 Btu/h · Ducted2.0075%8.115.5Xcel9213892585
532288BNV025*0**B*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**2517AL*+UI and furnace 88*TA48090C17Carrier2 tons24,400 Btu/h · Ducted2.0478%8.517.5CEE 25CEE 26Xcel485204456499
533288BNV025*0**C*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**2517AL*+UI and furnace 88*TA48090C17Carrier2 tons24,400 Btu/h · Ducted2.0478%8.517.5CEE 25CEE 26Xcel772206765555
534288BNV037*0**A*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CAP**6124AL*+UI and furnace 88*TA66135C24Carrier3 tons33,200 Btu/h · Ducted2.0278%8.518.0CEE 25CEE 26Xcel588210596553
535288BNV037*0**B*BRYANT HEATING AND COOLING SYSTEMS · EVOLUTION V Heat Pumpwith indoor coil CSPH*6012AL*+UI and furnace 88*TB60110C21Carrier3 tons33,000 Btu/h · Ducted2.0479%8.116.5CEE 25CEE 26Xcel606213782256
53638MARBQ06AA3PAYNE · 38MAR-serieswith ductless indoor unit DHMAHBQ06XA3Carrier0.5 tons6,000 Btu/h · Non-ducted2.09107%13.626.5CEE 25CEE 26XcelES CC8207188935
53738MARBQ09AA3CARRIER · 38MAR-serieswith ductless indoor unit 40MAHBQ09XA3Carrier1 ton9,000 Btu/h · Ducted and non-ducted1.9788%11.528.1CEE 25CEE 26XcelES CC24206348135
53838MARBQ12AA3CARRIER · 38MAR-serieswith ductless indoor unit 40MBFAQ12XA3Carrier1 ton12,000 Btu/h · Ducted and non-ducted1.9999%10.724.2CEE 25CEE 26XcelES CC32209948186
53938MARBQ18AA3CARRIER · 38MAR-serieswith ducted air handler 40MBDAQ18XH3Carrier1.5 tons17,500 Btu/h · Ducted and non-ducted2.2095%10.818.0CEE 25CEE 26XcelES CC74211132918
54038MARBQ24AA3CARRIER · 38MAR-serieswith ductless indoor unit 40MAHBQ24XA3Carrier2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC28206348138
54138MBRCQ48AA3CARRIER · 38MB-serieswith ductless indoor unit 40MBCAQ48XA3Carrier4 tons48,000 Btu/h · Ducted and non-ducted1.9869%9.818.5XcelES CC20207683289
54238MBRQ48A--3CARRIERwith ducted air handler 40MBDQ48---3Carrier4 tons48,000 Btu/h · Ducted and non-ducted2.0377%9.315.1Xcel12200059149
54338MGHBQ24CA3CARRIER · 38MG-seriesCarrier2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9074%10.024.6CEE 25CEE 26XcelES CC12207642879
54438MGHBQ30DA3CARRIER · 38MG-seriesCarrier2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8084%9.826.0CEE 25CEE 26XcelES CC12207642882
54538MGHBQ36DA3CARRIER · 38MG-seriesCarrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%10.322.2CEE 25CEE 26XcelES CC12207642891
54638MGHBQ48EA3CARRIER · 38MG-seriesCarrier4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%9.821.8CEE 25CEE 26XcelES CC12207642888
54738MGRBQ18BA3CARRIER · 38MG-seriesCarrier1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.522.9CEE 25CEE 26XcelES CC12207642876
54838MHRCQ09AA1CARRIER · 38MH-serieswith ductless indoor unit 40MHHAQ09XA1Carrier1 ton9,000 Btu/h · Non-ducted2.1670%9.121.5CEE 25CEE 26XcelES CC4208447844
54938MHRCQ09AA3CARRIER · 38MH-serieswith ductless indoor unit 40MHHAQ09XA3Carrier1 ton9,000 Btu/h · Non-ducted1.9970%9.421.7CEE 25CEE 26XcelES CC4208447845
55038MPRBQ09AA3CARRIER · 38MP-serieswith ductless indoor unit 40MPHBQ09XA3Carrier1 ton9,000 Btu/h · Non-ducted1.85114%12.028.5CEE 25CEE 26XcelES CC10207614949

Explore qualifying models by COP at 5°F