Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel Energy Colorado cold-climate ASHP (2025): 3,624 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
New to heat pump ratings? The Simple view explains them in plain words →
Xcel EnergyData as of updated · sources
- Share of models
- 37.6%
- Qualifying models
- 3,624
- Qualifying certifications
- 83,159
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 33 |
| 1.40 to under 1.50 | 118 |
| 1.50 to under 1.60 | 83 |
| 1.60 to under 1.70 | 113 |
| 1.70 to under 1.80 | 710 |
| 1.80 to under 1.90 | 2,084 |
| 1.90 to under 2.00 | 1,248 |
| 2.00 to under 2.10 | 1,265 |
| 2.10 to under 2.20 | 597 |
| 2.20 to under 2.30 | 469 |
| 2.30 to under 2.40 | 337 |
| 2.40 to under 2.50 | 165 |
| 2.50 to under 2.60 | 113 |
| 2.60 to under 2.70 | 126 |
| 2.70 to under 2.80 | 98 |
| 2.80 to under 2.90 | 76 |
| 2.90 to under 3.00 | 40 |
| 3.00 to under 3.10 | 37 |
| 3.10 to under 3.20 | 20 |
| 3.20 and above | 23 |
| Baseline: median | 1.93 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 11 |
| 30 to under 35% | 66 |
| 35 to under 40% | 352 |
| 40 to under 45% | 195 |
| 45 to under 50% | 286 |
| 50 to under 55% | 598 |
| 55 to under 60% | 783 |
| 60 to under 65% | 884 |
| 65 to under 70% | 798 |
| 70 to under 75% | 1,046 |
| 75 to under 80% | 472 |
| 80 to under 85% | 529 |
| 85 to under 90% | 414 |
| 90 to under 95% | 387 |
| 95 to under 100% | 270 |
| 100 to under 105% | 385 |
| 105 to under 110% | 74 |
| 110 to under 115% | 81 |
| 115 to under 120% | 27 |
| 120 to under 125% | 45 |
| 125 to under 130% | 13 |
| 130% and above | 31 |
| Baseline: median | 69% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 13.0 | 43 |
| 13.0 to under 13.5 | 658 |
| 13.5 to under 14.0 | 22 |
| 14.0 to under 14.5 | 570 |
| 14.5 to under 15.0 | 317 |
| 15.0 to under 15.5 | 986 |
| 15.5 to under 16.0 | 347 |
| 16.0 to under 16.5 | 714 |
| 16.5 to under 17.0 | 306 |
| 17.0 to under 17.5 | 523 |
| 17.5 to under 18.0 | 319 |
| 18.0 to under 18.5 | 370 |
| 18.5 to under 19.0 | 277 |
| 19.0 to under 19.5 | 590 |
| 19.5 to under 20.0 | 163 |
| 20.0 to under 20.5 | 480 |
| 20.5 to under 21.0 | 259 |
| 21.0 to under 21.5 | 534 |
| 21.5 to under 22.0 | 326 |
| 22.0 to under 22.5 | 337 |
| 22.5 to under 23.0 | 182 |
| 23.0 to under 23.5 | 295 |
| 23.5 to under 24.0 | 167 |
| 24.0 to under 24.5 | 106 |
| 24.5 to under 25.0 | 55 |
| 25.0 to under 25.5 | 33 |
| 25.5 to under 26.0 | 56 |
| 26.0 to under 26.5 | 49 |
| 26.5 to under 27.0 | 37 |
| 27.0 to under 27.5 | 31 |
| 27.5 to under 28.0 | 26 |
| 28.0 to under 28.5 | 48 |
| 28.5 and above | 34 |
| Baseline: median | 17.5 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 244 |
| 8.5 to under 9.0 | 584 |
| 9.0 to under 9.5 | 515 |
| 9.5 to under 10.0 | 387 |
| 10.0 to under 10.5 | 900 |
| 10.5 to under 11.0 | 1,155 |
| 11.0 to under 11.5 | 964 |
| 11.5 to under 12.0 | 1,095 |
| 12.0 to under 12.5 | 908 |
| 12.5 to under 13.0 | 1,265 |
| 13.0 to under 13.5 | 568 |
| 13.5 to under 14.0 | 228 |
| 14.0 to under 14.5 | 126 |
| 14.5 to under 15.0 | 44 |
| 15.0 to under 15.5 | 95 |
| 15.5 to under 16.0 | 77 |
| 16.0 to under 16.5 | 68 |
| 16.5 and above | 33 |
| Baseline: median | 11.3 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons54.1% · 1,693 of 3,129
- 2 tons46.3% · 665 of 1,436
- 2.5–3 tons31.3% · 809 of 2,587
- 3.5–4.5 tons20.1% · 429 of 2,136
- 5 tons and up8% · 28 of 349
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 54.1% · 1,693 of 3,129 |
| 2 tons | 46.3% · 665 of 1,436 |
| 2.5–3 tons | 31.3% · 809 of 2,587 |
| 3.5–4.5 tons | 20.1% · 429 of 2,136 |
| 5 tons and up | 8% · 28 of 349 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 20.5% | 931 / 4,546 |
| Non-ducted | 43.1% | 1,394 / 3,236 |
| Ducted and non-ducted | 70% | 1,299 / 1,855 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 223 of 395 | 56.5% |
| Mitsubishi Electric | 200 of 373 | 53.6% |
| Midea | 180 of 402 | 44.8% |
| Carrier | 120 of 701 | 17.1% |
| Rheem | 102 of 291 | 35.1% |
| Hisense | 94 of 159 | 59.1% |
| Lennox | 92 of 313 | 29.4% |
| Trane | 68 of 309 | 22% |
| Fujitsu | 56 of 164 | 34.1% |
| Daikin | 55 of 367 | 15% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 601HVH837GKA**HEILwith ducted air handler AE(D,N,U)+CM36B34+TDR | Carrier | 2.5 tons29,600 Btu/h · Ducted | 2.86 | 98% | 7.8 | 17.9 | CEE 25CEE 26Xcel | 1,746 | 213885813 |
| 602HVH837GKA2*HEILwith ducted air handler AE(D,N,U)+CM36B34+TDR | Carrier | 2.5 tons32,200 Btu/h · Ducted | 2.95 | 99% | 8.5 | 18.5 | CEE 25CEE 26Xcel | 1,797 | 213885816 |
| 603HVH848GKA**HEILwith ducted air handler AE(D,N,U)+CM60B34+TDR | Carrier | 3.5 tons43,500 Btu/h · Ducted | 2.79 | 78% | 8.0 | 18.0 | CEE 25Xcel | 542 | 213885819 |
| 604HVH848GKA2*HEILwith ducted air handler AE(D,N,U)+CM60B34+TDR | Carrier | 3.5 tons43,500 Btu/h · Ducted | 2.79 | 78% | 8.4 | 18.0 | CEE 25CEE 26Xcel | 610 | 213885823 |
| 605MCY-MAP0367HS-ULTOSHIBA CARRIER · MCY-MAP0367HS-UL | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted | 3.05 | 76% | 10.9 | 20.1 | CEE 25CEE 26Xcel | 2 | 10049878 |
| 606MCY-MAP0367HS-UL*TOSHIBA CARRIER · MCY-MAP0367HS-UL* | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.70 | 79% | 10.0 | 22.8 | CEE 25CEE 26XcelES CC | 3 | 213350249 |
| 607MCY-MAP0487HS-UL*TOSHIBA CARRIER · MCY-MAP0487HS-UL* | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.60 | 79% | 10.3 | 22.6 | CEE 25CEE 26Xcel | 3 | 213350250 |
| 608MCY-MAP0607HS-UL*TOSHIBA CARRIER · MCY-MAP0607HS-UL* | Carrier | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.40 | 78% | 10.6 | 23.1 | CEE 25CEE 26Xcel | 3 | 213350252 |
| 609N4H5S24*K*AAA*TEMPSTARwith indoor coil D(A,C,E)30C44+TDR and furnace *92MSN1002120A | Carrier | 2 tons23,800 Btu/h · Ducted | 3.02 | 75% | 7.6 | 15.5 | Xcel | 4,884 | 213822140 |
| 610R4H5S24*K*AAA*COMFORTMAKERwith indoor coil D(A,C,E)24B34+TDR and furnace *80ESU0401712A | Carrier | 2 tons22,000 Btu/h · Ducted | 2.70 | 62% | 7.6 | 14.9 | Xcel | 4,721 | 214825859 |
| 611RAV-SP122AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM122KRTP-UL | Carrier | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.48 | 71% | 11.1 | 25.2 | CEE 25CEE 26Xcel | 2 | 208429503 |
| 612RAV-SP182AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM182UTP-UL | Carrier | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.45 | 71% | 11.3 | 25.5 | CEE 25CEE 26Xcel | 4 | 208447319 |
| 613RAV-SP242AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM242CTP-UL | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.30 | 71% | 10.4 | 23.2 | CEE 25CEE 26Xcel | 4 | 208447322 |
| 614RAV-SP302AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM302UTP-UL | Carrier | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.50 | 71% | 11.2 | 23.7 | CEE 25CEE 26Xcel | 4 | 208447324 |
| 615RAV-SP362AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM362UTP-UL | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.47 | 70% | 11.1 | 24.3 | CEE 25CEE 26Xcel | 4 | 208447327 |
| 616RAV-SP422AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM422CTP-UL | Carrier | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 2.15 | 71% | 10.7 | 19.6 | CEE 25CEE 26Xcel | 3 | 208447330 |
| 617RAV-SP482AT2P-ULTOSHIBA CARRIERwith ductless indoor unit RAV-SM482UTP-UL | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.02 | 71% | 9.8 | 22.4 | CEE 25CEE 26Xcel | 3 | 208429509 |
| 618T4H5S24*K*AAA*TEMPSTARwith indoor coil D(A,C,E)30C44+TDR and furnace *80CTL0901716A | Carrier | 2 tons23,800 Btu/h · Ducted | 2.84 | 54% | 7.9 | 16.0 | Xcel | 550 | 213199863 |
| 619TVH825GKA2*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716A | Carrier | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 505 | 204456507 |
| 620TVH825GKA3*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X37L21A*+WALLCON and furnace *80CTL0901716A | Carrier | 2 tons24,600 Btu/h · Ducted | 2.24 | 86% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 759 | 206766040 |
| 621TVH837GKA**TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120A | Carrier | 2.5 tons31,800 Btu/h · Ducted | 2.10 | 83% | 7.5 | 17.0 | CEE 25CEE 26Xcel | 581 | 204299604 |
| 622TVH837GKA2*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122A | Carrier | 3 tons33,200 Btu/h · Ducted | 2.24 | 86% | 8.5 | 18.0 | CEE 25CEE 26Xcel | 598 | 210470538 |
| 623TVH848GKA2*TEMPSTAR · SMARTCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CSU0802120A | Carrier | 4 tons45,500 Btu/h · Ducted | 2.32 | 71% | 8.5 | 17.0 | CEE 25CEE 26Xcel | 201 | 206774828 |
| 624W4H5S24*K*AAA*GRANDAIREwith ducted air handler AE*S+CM24C34+TDR | Carrier | 2 tons22,600 Btu/h · Ducted | 2.57 | 59% | 7.5 | 15.2 | Xcel | 631 | 215853231 |
| 625WDLCURAH18ABKGRANDAIREwith ducted air handler FMA4X18**AL | Carrier | 1.5 tons17,400 Btu/h · Ducted | 2.44 | 108% | 8.5 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 286 | 211264940 |