Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 45 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1101MOX430-17HFN1-MT0WECO-AIR · MOX Serieswith ducted air handler MVC-18HWFN1-MW(GA)ECO-AIR1.5 tons18,000 Btu/h · Ducted and non-ducted2.0089%9.617.6CEE 25CEE 26XcelES CC5211644112
1102MOX430-18HFN1-MU0WECO-AIR · MOX Serieswith ducted air handler MTIU-18HWFN1-MECO-AIR1.5 tons17,000 Btu/h · Ducted and non-ducted2.4065%10.620.0CEE 25CEE 26XcelES CC4211644051
1103MOX430U-18HFN1-MECO-AIR · MOX Serieswith ducted air handler MVBE-18HWFN1-MM3EECO-AIR1.5 tons18,000 Btu/h · Ducted2.3099%10.819.3CEE 25CEE 26CEE AdvXcelDOEES CC4213307908
1104MOX430U-24HFN1-MR0ECO-AIR · MOX Serieswith ducted air handler MAC-24HWDN1-MN0ECO-AIR2 tons24,000 Btu/h · Ducted2.2072%9.815.7CEE 25CEE 26XcelES CC4209270314
1105MOX630-36HFN1-M3XECO-AIR · MOX Serieswith ducted air handler MVB-36B23T4N1ECO-AIR3 tons35,000 Btu/h · Ducted1.8083%8.515.2CEE 25CEE 26XcelES CC4213386481
1106EODA18H-2436ECOERwith ducted air handler AE(D,N,U)+CM30B24+TDREcoer1.5 tons20,000 Btu/h · Ducted2.8280%8.516.0CEE 25CEE 26Xcel22213885835
1107EODA18H-2436BECOERwith ducted air handler AE(D,N,U)+CM30B24+TDREcoer1.5 tons20,600 Btu/h · Ducted2.6593%9.118.0CEE 25CEE 26Xcel45213885836
1108EODA18H-2436BAAECOER · ESi Decades Extremewith ducted air handler EAHATN-24BAAEcoer2 tons24,000 Btu/h · Ducted2.1082%9.220.0CEE 25CEE 26XcelES CC49214608194
1109EODA18H-4860ECOERwith ducted air handler AE(D,N,U)+CM48A34+TDREcoer3.5 tons40,500 Btu/h · Ducted2.6548%7.915.5CEE 25CEE 26Xcel31213885837
1110EODA18H-4860BECOERwith ducted air handler AE(D,N,U)+CM48A34+TDREcoer3.5 tons40,000 Btu/h · Ducted2.3984%8.317.6CEE 25CEE 26Xcel56213885838
1111EODA18H-4860BAAECOER · ESi Decades Extremewith ducted air handler EAHATN-36BAAEcoer3 tons35,200 Btu/h · Ducted2.1081%9.219.0CEE 25CEE 26Xcel53214608195
1112EODA19H-2436AECOERwith ducted air handler EAHATN-24BEcoer2 tons24,000 Btu/h · Ducted2.1082%9.520.5CEE 25CEE 26Xcel19214303508
1113EODA19H-2436AA*ECOER · TDi Prowith ducted air handler EAHATN-24BAEcoer2 tons24,000 Btu/h · Ducted2.1082%9.520.5CEE 25CEE 26XcelES CC38214660539
1114EODA19H-4860AECOERwith ducted air handler EAHATN-48BEcoer4 tons47,000 Btu/h · Ducted2.1072%9.519.0CEE 25CEE 26Xcel18214303510
1115EODA19H-4860AA*ECOER · TDi Prowith ducted air handler EAHATN-48BAEcoer4 tons47,000 Btu/h · Ducted2.1072%9.519.0CEE 25CEE 26XcelES CC37214660541
1116ERDA19H-60AA*ECOER · RTiEcoer4.5 tons55,000 Btu/h · Ducted1.9070%9.218.5CEE 25CEE 26XcelES CC1214728308
1117ESCA16H-36Ecoer · SDi Decades Extremewith ducted air handler SNC36CPTEcoer3 tons35,000 Btu/h · Ducted2.0082%10.015.2CEE 25CEE 26XcelES CC2213386490
1118ESCA16H-60Ecoer · SDi Decades Extremewith ducted air handler EAHAEC-60Ecoer4.5 tons55,000 Btu/h · Ducted1.9182%9.415.3XcelES CC4211594474
1119EOD30-24HFN1-MWEconaswith ducted air handler EVBM-24A18T3N1Econas2 tons24,000 Btu/h · Ducted2.0080%9.816.1CEE 25CEE 26Xcel2214296068
1120EOD30U-30HFN1-MR0(X)Econaswith ducted air handler EAC-36HWDN1-MN0Econas2.5 tons30,000 Btu/h · Ducted1.8582%9.715.5Xcel2214296071
1121EOE30U-45HFN1-MEconaswith ducted air handler EAC-60HWDN1-MN0Econas4 tons45,000 Btu/h · Ducted1.8085%9.215.2Xcel1214296075
1122EOE31U-36HFN1-MEconaswith ducted air handler EAC-36HWDN1-MN0Econas3 tons35,000 Btu/h · Ducted2.0082%10.015.2Xcel2214296073
1123DE18HOS25230E3AELIOS · DE-serieswith ductless indoor unit DE18HIW23230E3ELIOS1.5 tons17,000 Btu/h · Ducted and non-ducted1.9091%10.019.4CEE 25CEE 26XcelES CC3206401445
1124DE24HOS25230E3AELIOS · DE-serieswith ductless indoor unit DE24HIW23230E3ELIOS2 tons21,600 Btu/h · Ducted and non-ducted2.07100%10.418.9CEE 25CEE 26XcelES CC2206401448
1125DEA06HOS28230E8ELIOS · DE-serieswith ductless indoor unit DEA06HIW25230E8ELIOS0.5 tons6,000 Btu/h · Non-ducted2.09107%13.626.5CEE 25CEE 26XcelES CC1207742428

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter