Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,653 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.7%
Qualifying models
3,653
Qualifying certifications
83,192
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,806 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50123
1.50 to under 1.6087
1.60 to under 1.70115
1.70 to under 1.80716
1.80 to under 1.902,089
1.90 to under 2.001,247
2.00 to under 2.101,265
2.10 to under 2.20607
2.20 to under 2.30477
2.30 to under 2.40345
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,798 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%366
40 to under 45%200
45 to under 50%286
50 to under 55%599
55 to under 60%783
60 to under 65%885
65 to under 70%799
70 to under 75%1,049
75 to under 80%488
80 to under 85%537
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%387
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,312 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.51,004
15.5 to under 16.0355
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5371
18.5 to under 19.0279
19.0 to under 19.5593
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,312 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,175
11.0 to under 11.5983
11.5 to under 12.01,096
12.0 to under 12.5918
12.5 to under 13.01,266
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,130
2 tons46.4% · 668 of 1,440
2.5–3 tons31.4% · 818 of 2,606
3.5–4.5 tons20.6% · 446 of 2,161
5 tons and up7.8% · 28 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.8%956 / 4,597
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,303 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Lennox121 of 37132.6%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 49 of 147
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1201FPHSR09A3A-AFRIEDRICH · Prowith ductless indoor unit FPHFW09A3BFriedrich1 ton9,000 Btu/h · Non-ducted1.8880%9.022.0CEE 25CEE 26XcelES CC1205142783
1202FPHSR12A1AFRIEDRICH · Prowith ductless indoor unit FPHSW12A1AFriedrich1 ton12,000 Btu/h · Non-ducted1.7570%9.521.7CEE 25CEE 26Xcel1203383868
1203FPHSR12A1A-AFRIEDRICH · Prowith ductless indoor unit FPHSW12A1BFriedrich1 ton12,000 Btu/h · Non-ducted1.7570%9.521.7CEE 25CEE 26Xcel1205142782
1204FPHSR12A3AFRIEDRICH · Prowith ductless indoor unit FPHFW12A3AFriedrich1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel1203383866
1205FPHSR12A3A-AFRIEDRICH · Prowith ductless indoor unit FPHFW12A3BFriedrich1 ton12,000 Btu/h · Non-ducted1.8580%9.521.0CEE 25CEE 26Xcel1205142785
1206FPHSR18A3A-AFRIEDRICH · Prowith ductless indoor unit FPHFW18A3BFriedrich1.5 tons18,000 Btu/h · Non-ducted1.8777%9.222.5CEE 25CEE 26XcelES CC1205142786
1207FPHSR24A3AFRIEDRICH · Prowith ductless indoor unit FPHFW24A3AFriedrich2 tons23,000 Btu/h · Non-ducted1.7578%8.620.5CEE 25CEE 26XcelES CC1203383870
1208FPHSR24A3A-AFRIEDRICH · Prowith ductless indoor unit FPHFW24A3BFriedrich2 tons23,000 Btu/h · Non-ducted1.9189%8.620.5CEE 25CEE 26XcelES CC1205142787
1209FRHSR12A3AFRIEDRICH · Premierwith ductless indoor unit FRHSW12A3AFriedrich1 ton12,000 Btu/h · Non-ducted1.7570%9.823.5CEE 25CEE 26XcelES CC1203383864
1210FRHSR12A3A-AFRIEDRICH · Premierwith ductless indoor unit FRHSW12A3BFriedrich1 ton12,000 Btu/h · Non-ducted1.7570%9.823.5CEE 25CEE 26XcelES CC1205142789
1211FRP18AZ24AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHUFriedrich2 tons22,800 Btu/h · Ducted2.10108%8.520.0CEE 25CEE 26CEE AdvXcelDOEES CC21213829710
1212FRP18AZ36AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHUFriedrich3 tons34,200 Btu/h · Ducted2.20121%8.519.0CEE 25CEE 26CEE AdvXcelDOEES CC23213829722
1213FRP18AZ48AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ6021SEAAM and furnace FR801V1005A21UHUFriedrich3.5 tons44,500 Btu/h · Ducted2.00105%8.119.0CEE 25CEE 26XcelES CC21213829739
1214FRP18AZ60AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ6021SEAAM and furnace FR98MV1005A21UPFriedrich4.5 tons52,500 Btu/h · Ducted2.0095%8.118.0Xcel11214610150
1215MRAD24Y3JFRIEDRICHwith ductless indoor unit MWAD24Y3JFriedrich2 tons22,000 Btu/h · Non-ducted1.7583%8.520.0CEE 25CEE 26Xcel110221178
1216MRH09Y3JAFRIEDRICHwith ductless indoor unit MWH09Y3JAFriedrich1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26Xcel1201763897
1217MRH12Y3JAFRIEDRICHwith ductless indoor unit MWH12Y3JAFriedrich1 ton12,000 Btu/h · Non-ducted1.7570%9.823.5CEE 25CEE 26Xcel1201763898
1218RD17AZ24AJ3NFRIEDRICHwith indoor coil RCFZ2417STANM and furnace FR921V0703A17M4Friedrich2 tons22,400 Btu/h · Ducted2.3039%8.518.0CEE 25CEE 26XcelES CC108214773022
1219RD17AZ36AJ3NFRIEDRICHwith ducted air handler FRB2TZ3621STANMFriedrich2.5 tons32,000 Btu/h · Ducted2.5058%8.116.0CEE 25CEE 26XcelES CC132214100074
1220RD17AZ48AJ3NFRIEDRICHwith indoor coil TCFZ6024STANM and furnace FR801V1255A24DZFriedrich4 tons45,500 Btu/h · Ducted2.4056%8.116.0CEE 25CEE 26XcelES CC144214075605
1221RD17AZ60AJ3NFRIEDRICH · F-SERIES PLUSwith indoor coil TCFZ6021STAAM and furnace FR802V1005A21DZFriedrich4.5 tons52,500 Btu/h · Ducted2.1052%7.514.3XcelES CC52214075269
1222WFPU17Z243CFRIEDRICHwith ducted air handler D(A,C,E)24D34+TDRFriedrich1.5 tons20,800 Btu/h · Ducted2.80100%7.514.3CEE 25CEE 26XcelES CC64214638706
1223WFPU18Z363CFRIEDRICHwith ducted air handler L(E,G)M36F4Friedrich3 tons33,800 Btu/h · Ducted2.6169%9.017.0CEE 25CEE 26XcelES CC55215550848
1224WFPU18Z483CFRIEDRICHwith ducted air handler L(E,G)M60B4Friedrich4 tons46,500 Btu/h · Ducted2.3565%8.217.0CEE 25CEE 26XcelES CC49215550850
1225FES-09H1T*(O)FUJIECOwith ductless indoor unit FES-09H1TK(I)FUJIECO1 ton9,000 Btu/h · Non-ducted1.7570%8.519.0CEE 25CEE 26Xcel1212386851