Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 51 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1251AOU24RGLXFUJITSU · H-Serieswith ductless indoor unit AUU24RGLXNot ranked: cold-weather ratings look inconsistent.Fujitsu2 tons24,000 Btu/h · Ducted and non-ducted2.9797%10.120.8CEE 25CEE 26Xcel3202208444
1252AOU24RLXFWHFUJITSU · H-Serieswith ductless indoor unit ASU24RLFFujitsu2 tons22,000 Btu/h · Non-ducted2.0397%10.519.5CEE 25CEE 26XcelES CC18779046
1253AOU24RLXFZHFUJITSU · H-SeriesFujitsu2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.08107%9.618.9CEE 25CEE 26XcelES CC38063925
1254AOU30RGLXFUJITSUwith ductless indoor unit AUU30RGLXFujitsu2.5 tons30,000 Btu/h · Ducted and non-ducted2.3081%10.418.7CEE 25CEE 26Xcel3202195636
1255AOU30RLXEHFUJITSU · H-Serieswith ductless indoor unit ASU30RLEFujitsu2.5 tons30,000 Btu/h · Non-ducted2.06107%10.018.7CEE 25CEE 26XcelES CC18912454
1256AOU36RGLXFUJITSUwith ductless indoor unit AUU36RGLXFujitsu3 tons36,000 Btu/h · Ducted and non-ducted2.3274%9.718.0CEE 25CEE 26Xcel2202195637
1257AOU36RLAVM4FUJITSUFujitsu3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9882%9.117.4CEE 25CEE 26Xcel3206347301
1258AOU36RLAVS4FUJITSUFujitsu3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0380%8.818.0CEE 25CEE 26Xcel3206347303
1259AOU36RLXFZHFUJITSU · H-SeriesFujitsu3 tons35,200 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.02101%9.520.5CEE 25CEE 26XcelES CC38908615
1260AOU42RGLXFUJITSUwith ductless indoor unit AUU42RGLXFujitsu3.5 tons42,000 Btu/h · Ducted and non-ducted2.2881%9.819.0CEE 25CEE 26Xcel2202195867
1261AOU48RLAVM4FUJITSUFujitsu4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2573%9.118.0CEE 25CEE 26Xcel3206347300
1262AOU9RLFFFUJITSU · H-Serieswith ductless indoor unit AGU9RLFFujitsu1 ton9,000 Btu/h · Non-ducted1.98158%11.826.0CEE 25CEE 26XcelES CC16936995
1263AOU9RLFFHFUJITSU · H-Serieswith ductless indoor unit AGU9RLFFujitsu1 ton9,000 Btu/h · Non-ducted1.85158%11.626.0CEE 25CEE 26XcelES CC16937309
1264AOUG12LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZASFujitsu1 ton12,000 Btu/h · Non-ducted2.16138%12.729.4CEE 25CEE 26CEE AdvXcelDOEES CC2204740069
1265AOUG12LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG12LZASFujitsu1 ton12,000 Btu/h · Non-ducted2.32138%12.929.4CEE 25CEE 26CEE AdvXcelDOEES CC2204740068
1266AOUG15LZAH1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZASFujitsu1 ton14,500 Btu/h · Non-ducted2.12145%12.725.3CEE 25CEE 26CEE AdvXcelDOEES CC2204740071
1267AOUG15LZAS1FUJITSU · H-Serieswith ductless indoor unit ASUG15LZASFujitsu1 ton14,500 Btu/h · Non-ducted2.24145%12.825.3CEE 25CEE 26CEE AdvXcelDOEES CC2204740070
1268AOUG36LMAS1FUJITSU · H-Serieswith ducted air handler AMUG36LMASFujitsu3 tons36,000 Btu/h · Ducted2.0091%8.817.1CEE 25CEE 26XcelES CC1205123809
1269AOUH09LEAS1FUJITSU · H-Serieswith ductless indoor unit ASUH09LMASFujitsu1 ton9,000 Btu/h · Non-ducted1.9690%10.021.3CEE 25CEE 26XcelES CC1207454671
1270AOUH09LMAH1FUJITSU · H-Serieswith ductless indoor unit ASUH09LMASFujitsu1 ton9,000 Btu/h · Non-ducted2.01104%12.326.5CEE 25CEE 26XcelES CC1206263449
1271AOUH09LMAS1FUJITSU · H-Serieswith ductless indoor unit ASUH09LMASFujitsu1 ton9,000 Btu/h · Non-ducted2.35113%12.626.5CEE 25CEE 26CEE AdvXcelDOEES CC1207615688
1272AOUH09LPAS1FUJITSU · H-Serieswith ductless indoor unit ASUH09LPASFujitsu1 ton9,000 Btu/h · Non-ducted2.0774%10.520.0CEE 25CEE 26Xcel1206909902
1273AOUH09LUAS1FUJITSU · H-Serieswith ductless indoor unit ACUH09LUAS1Fujitsu1 ton9,000 Btu/h · Ducted and non-ducted2.23112%11.823.5CEE 25CEE 26CEE AdvXcelDOEES CC2206579743
1274AOUH12LMAH1FUJITSU · H-Serieswith ductless indoor unit ASUH12LMASFujitsu1 ton12,000 Btu/h · Non-ducted2.2789%11.223.0CEE 25CEE 26Xcel1206263450
1275AOUH12LMAS1FUJITSU · H-Serieswith ductless indoor unit ASUH12LMASFujitsu1 ton12,000 Btu/h · Non-ducted2.4589%11.123.0CEE 25CEE 26Xcel1207615689

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy