Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 53 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1301ASH109PRDB**GE Appliances · Altitudewith ductless indoor unit ASYW09PRDBGE Appliances1 ton9,000 Btu/h · Non-ducted1.8185%9.623.5CEE 25CEE 26XcelES CC1211709322
1302ASH109URDE**GE Appliances · Endurewith ductless indoor unit ASYW09URDENot ranked: cold-weather ratings look inconsistent.GE Appliances1 ton9,000 Btu/h · Ducted and non-ducted1.89106%14.030.0CEE 25CEE 26XcelES CC4212409456
1303ASH112CRDD**GE Applianceswith ductless indoor unit ASYW12CRDDGE Appliances1 ton12,000 Btu/h · Non-ducted1.8070%9.219.0CEE 25CEE 26Xcel1210715478
1304ASH112PRDB**GE Appliances · Altitudewith ductless indoor unit ASYW12PRDBGE Appliances1 ton12,000 Btu/h · Non-ducted1.8080%10.523.0CEE 25CEE 26XcelES CC1211709323
1305ASH112PRDWAGE Appliances · Altitudewith ductless indoor unit ASYW12PRDWBGE Appliances1 ton12,000 Btu/h · Non-ducted1.8072%10.223.0CEE 25CEE 26Xcel1202588311
1306ASH112URDE**GE Appliances · Endurewith ductless indoor unit ASYW12URDEGE Appliances1 ton12,000 Btu/h · Ducted and non-ducted2.31117%12.527.5CEE 25CEE 26CEE AdvXcelDOEES CC4212409457
1307ASH115PRDB**GE Appliances · Altitudewith ductless indoor unit ASYW15PRDBGE Appliances1.5 tons15,000 Btu/h · Non-ducted1.8089%9.621.5CEE 25CEE 26XcelES CC1211709324
1308ASH115PRDWAGE Appliances · Altitudewith ductless indoor unit ASYW15PRDWBGE Appliances1.5 tons15,000 Btu/h · Non-ducted1.8073%9.621.5CEE 25CEE 26Xcel1202588312
1309ASH118PRDB**GE Appliances · Altitudewith ductless indoor unit ASYW18PRDBGE Appliances1.5 tons17,000 Btu/h · Non-ducted1.8075%9.621.0CEE 25CEE 26XcelES CC1211709325
1310ASH118URDE**GE Appliances · Endurewith ductless indoor unit ASYW18URDEGE Appliances1.5 tons17,800 Btu/h · Ducted and non-ducted2.34100%12.023.0CEE 25CEE 26CEE AdvXcelDOEES CC4212409458
1311ASH124PRDB**GE Appliances · Altitudewith ductless indoor unit ASYW24PRDBGE Appliances2 tons22,000 Btu/h · Non-ducted1.8072%9.620.0CEE 25CEE 26XcelES CC1211709326
1312ASH124PRDWAGE Appliances · Altitudewith ductless indoor unit ASYW24PRDWBGE Appliances2 tons22,000 Btu/h · Non-ducted1.8072%9.520.0CEE 25CEE 26Xcel1202588314
1313ASH124TRDF**GE Appliances · ASH124TRDF**with ductless indoor unit ASYW24TRDFGE Appliances2 tons23,000 Btu/h · Non-ducted1.7584%9.520.0CEE 25CEE 26XcelES CC1207769100
1314ASH124UCDD**GE Appliances · Endure PROwith ducted air handler USYM24UCDDGE Appliances2 tons24,000 Btu/h · Ducted and non-ducted1.8077%8.116.5CEE 25CEE 26XcelES CC3211727011
1315ASH220NCDD**GE Appliances · EndureGE Appliances1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0084%10.218.0CEE 25CEE 26XcelES CC3210154187
1316ASH3036TRDF**GE Appliances · ASH3036TRDF**with ductless indoor unit ASYW30TRDFGE Appliances2.5 tons30,000 Btu/h · Non-ducted1.7570%9.018.0XcelES CC2207769101
1317ASH3036UCDD**GE Appliances · Endure PROwith ducted air handler USYM30UCDDGE Appliances2.5 tons30,000 Btu/h · Ducted and non-ducted1.8074%9.015.2CEE 25CEE 26XcelES CC6211727012
1318ASH324NCDD**GE Appliances · EndureGE Appliances2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9073%10.219.5CEE 25CEE 26XcelES CC3210154192
1319ASH436NCDD**GE Appliances · EndureGE Appliances3 tons33,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0072%9.519.0XcelES CC3210154196
1320AUH2436ZGDA*GE Applianceswith ducted air handler F,PE*G33936GE Appliances3 tons33,200 Btu/h · Ducted2.2570%8.815.5CEE 25CEE 26XcelES CC72207764670
1321AUH4860ZGDA*GEwith ducted air handler D(A,C,E)60C44+TDRGE Appliances4 tons47,000 Btu/h · Ducted1.9172%8.515.2CEE 25CEE 26XcelES CC37212924883
1322NS17H48SA4-**AGEwith indoor coil D(A,C,E)48D44+TDR and furnace NF80D090S4B-GE Appliances4 tons46,500 Btu/h · Ducted2.9969%9.015.0CEE 25CEE 26Xcel884213884844
1323NS22H24MA4-**AGEwith ducted air handler L(E,F)W30F4GE Appliances2 tons21,800 Btu/h · Ducted2.8065%8.520.0CEE 25CEE 26Xcel257214839592
1324GNS-12HCH22TO1GENERALLUX STAR · E-starwith ductless indoor unit GNS-12HCH22TI1GENERALLUX STAR1 ton12,000 Btu/h · Non-ducted1.8580%9.521.0CEE 25CEE 26Xcel1213617766
1325GNS-12HCH23TO2GENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS-12HCH23TI2GENERALLUX STAR1 ton12,000 Btu/h · Non-ducted1.8983%9.523.5CEE 25CEE 26Xcel1213617768

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter