Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,627 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.6%
Qualifying models
3,627
Qualifying certifications
83,155
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,758 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above33 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4033
1.40 to under 1.50118
1.50 to under 1.6083
1.60 to under 1.70113
1.70 to under 1.80710
1.80 to under 1.902,085
1.90 to under 2.001,249
2.00 to under 2.101,265
2.10 to under 2.20597
2.20 to under 2.30470
2.30 to under 2.40337
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,750 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%352
40 to under 45%195
45 to under 50%286
50 to under 55%598
55 to under 60%783
60 to under 65%884
65 to under 70%798
70 to under 75%1,046
75 to under 80%472
80 to under 85%531
85 to under 90%415
90 to under 95%387
95 to under 100%270
100 to under 105%385
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,263 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5658
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.5987
15.5 to under 16.0347
16.0 to under 16.5716
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5370
18.5 to under 19.0277
19.0 to under 19.5590
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,263 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,156
11.0 to under 11.5964
11.5 to under 12.01,096
12.0 to under 12.5908
12.5 to under 13.01,265
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,694 of 3,130
2 tons46.3% · 666 of 1,437
2.5–3 tons31.3% · 810 of 2,588
3.5–4.5 tons20.1% · 429 of 2,136
5 tons and up8% · 28 of 349

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.5%934 / 4,549
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,299 / 1,855

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Lennox92 of 31329.4%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 6 of 146
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
126SC-30ZGLD-HP230BACIQwith ductless indoor unit SC-30WGLD-HP230BACIQ2.5 tons30,000 Btu/h · Non-ducted1.8177%8.520.0CEE 25CEE 26Xcel1211580579
127SC-36Z-HH-M4ACIQACIQ3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8278%8.616.0Xcel3208674924
128SC-36ZGLD-HP230BACIQwith ductless indoor unit SC-36WGLD-HP230BACIQ3 tons33,600 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel1211580583
129SC-42Z-HH-M5ACIQACIQ3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8274%8.616.0Xcel3208674927
130SC-4860-HPACIQ · Ultra Heat Unitary Condensing Unitwith ducted air handler SC-48-AHACIQ4 tons48,000 Btu/h · Ducted1.8081%9.017.0CEE 25CEE 26XcelES CC2211717287
131UB1MSHQCO09ACiQ · Hi MULTI Xtremewith ductless indoor unit UB1MSHQCW09ACIQ1 ton9,000 Btu/h · Non-ducted2.0981%9.018.5CEE 25CEE 26XcelES CC1208287562
132UB1MSHQCO12ACiQ · HiULTRAwith ductless indoor unit UB1MSHQCW12ACIQ1 ton12,000 Btu/h · Non-ducted1.8681%9.521.7CEE 25CEE 26Xcel1208287565
133UB1MSHQCO18ACiQ · Hi MULTI Xtremewith ductless indoor unit UB1MSHQCW18ACIQ1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26XcelES CC1208287567
134UB1MSHQCO24ACiQ · Hi MULTI Xtremewith ductless indoor unit UB1MSHQCW24ACIQ2 tons23,000 Btu/h · Non-ducted2.1389%8.620.5CEE 25CEE 26XcelES CC1208287568
1354TXD2036A10NU**ADPwith ducted air handler F,PE*E32930ADP2 tons23,000 Btu/h · Ducted2.10107%8.916.0CEE 25CEE 26CEE AdvXcelDOE15212396546
1364TXD2060A10NU**ADPwith ducted air handler F,PE*CC7948ADP4 tons48,000 Btu/h · Ducted1.8290%9.017.0CEE 25CEE 26Xcel19212396557
137AC024BXUPCHADPwith ducted air handler F,PE*BB9931ADP2 tons24,000 Btu/h · Ducted1.80100%8.116.5Xcel1211289593
138AC036BXUPCHADPwith ducted air handler F,PE*CC3937ADP3 tons36,000 Btu/h · Ducted1.80100%8.418.5Xcel1211289595
139AUH4860ZGDA*ADPwith ducted air handler HE49960+TDADP4 tons50,500 Btu/h · Ducted1.8062%8.415.2Xcel18212851779
140AUWR-36U3SA2ADPwith ducted air handler F,PE*TT3937ADP3 tons34,000 Btu/h · Ducted2.0577%9.517.0CEE 25CEE 26Xcel1215350408
141AUWR-48U3SP2ADPwith ducted air handler BV**C1942ADP3.5 tons41,000 Btu/h · Ducted1.9486%8.515.2Xcel3215350413
142BOVA-36HDN1-M20GADPwith indoor coil HE31930 and furnace BGH96M060B3AADP2 tons22,800 Btu/h · Ducted2.1277%8.718.0CEE 25CEE 26Xcel11212361441
143BOVA-60HDN1-M20GADPwith indoor coil HE35948 and furnace BGH96M100D5AADP3.5 tons44,500 Btu/h · Ducted2.5076%9.017.0CEE 25CEE 26Xcel40212361477
144DIRM-18MAGICPRO20-OUADPwith ducted air handler HG21924+TDADP1.5 tons17,700 Btu/h · Ducted2.2083%8.916.0CEE 25CEE 26Xcel2212897468
145DIRM-24MAGICPRO20-OUADPwith ducted air handler HG21924+TDADP2 tons23,000 Btu/h · Ducted1.9583%8.816.0CEE 25CEE 26Xcel2212897472
146DIRM-30MAGICPRO20-OUADPwith ducted air handler HE31930+TDADP2.5 tons28,600 Btu/h · Ducted1.8590%9.115.2Xcel7212897475
147DLCURAH18ABKADPwith ducted air handler H,GE30924+TDADP1.5 tons18,000 Btu/h · Ducted2.2083%9.116.0CEE 25CEE 26Xcel3213613871
148DLCURAH24ABKADPwith ducted air handler H,GE30924+TDADP2 tons24,000 Btu/h · Ducted1.9583%9.116.0CEE 25CEE 26Xcel3213613873
149DLCURAH36ABKADPwith ducted air handler H,GE32936+TDADP3 tons34,800 Btu/h · Ducted1.8588%8.215.2Xcel3213613877
150DMA18HOS20230E7ADPwith ducted air handler HE20918+TDADP1.5 tons17,100 Btu/h · Ducted2.2083%8.716.0CEE 25CEE 26Xcel10212614021

Explore qualifying models by COP at 5°F