Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 66 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1626HVHSC-18T2DHAXXAIR · Hi UNIwith ductless indoor unit HAHC-18T2DHAXXAIR1.5 tons18,000 Btu/h · Ducted and non-ducted2.3673%10.020.5CEE 25CEE 26Xcel3205921367
1627HVHSC-24T2DHAXXAIR · Hi UNIwith ductless indoor unit HAH-24T2DHAXXAIR2 tons24,000 Btu/h · Ducted and non-ducted2.2079%10.018.5CEE 25CEE 26Xcel2214855369
1628HVHSC-36T2DHAXXAIRwith ductless indoor unit HAH-36T2DHAXXAIR3 tons36,000 Btu/h · Ducted and non-ducted2.2874%9.818.0CEE 25CEE 26Xcel2214855370
1629DS-2MS0912HC230HEMAwith ductless indoor unit DS-2MS0912HE230HEMA1 ton9,000 Btu/h · Non-ducted1.8074%9.023.0CEE 25CEE 26Xcel1214802065
1630DS-2MS1212HC220HEMAwith ductless indoor unit DS-2MS1212HE220HEMA1 ton12,000 Btu/h · Non-ducted1.8073%9.022.0CEE 25CEE 26Xcel1214802066
1631H12E1Hessairewith ductless indoor unit H12E1Hessaire1 ton12,000 Btu/h · Non-ducted1.7570%9.521.7CEE 25CEE 26Xcel1206913622
1632H18E2Hessaire · ULTRAwith ductless indoor unit H18E2Hessaire1.5 tons18,000 Btu/h · Non-ducted1.8071%8.622.5CEE 25CEE 26XcelES CC1206913623
1633H24E2Hessaire · ULTRAwith ductless indoor unit H24E2Hessaire2 tons23,000 Btu/h · Non-ducted1.7578%8.620.5CEE 25CEE 26XcelES CC1213286799
1634HOC24Hessaire · H SERIESwith ducted air handler HAH24Hessaire2 tons22,000 Btu/h · Ducted2.0577%9.016.5CEE 25CEE 26XcelES CC1212524529
1635HOC36Hessaire · H SERIESwith ducted air handler HAH36Hessaire3 tons34,000 Btu/h · Ducted2.0576%9.518.0CEE 25CEE 26Xcel1212524530
1636AMW2-18U3SFAHISENSE · Hi MULTI XtremeHisense1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%9.419.0CEE 25CEE 26XcelES CC3204816625
1637AMW3-24U3SAAHISENSE · Hi MULTI Xtremewith ductless indoor unit AST-07UW3SVE**00Hisense2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%9.122.0CEE 25CEE 26XcelES CC4202864314
1638AMW4-36U3STAHISENSE · Hi MULTI Xtremewith ductless indoor unit AST-09UW3SVE**00Hisense2.5 tons32,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.84113%9.021.0CEE 25CEE 26XcelES CC4202911535
1639AMW5-42U3STAHISENSE · Hi MULTI XtremeHisense3.5 tons41,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8488%8.818.0CEE 25CEE 26XcelES CC3205123811
1640AS-09UR3SXE00HISENSE · HiULTRAwith ductless indoor unit AS-09UR3SXE**00Hisense1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26XcelES CC610102524
1641AS-09UW1SVE00HISENSE · HiULTRAwith ductless indoor unit AS-09UW1SVE**00Hisense1 ton9,000 Btu/h · Non-ducted2.0981%9.018.5CEE 25CEE 26XcelES CC1203377293
1642AS-09UW1SVE00AHISENSEwith ductless indoor unit AS-09UW1SVE**00AHisense1 ton9,000 Btu/h · Non-ducted1.8070%9.018.5CEE 25CEE 26Xcel1205092754
1643AS-09UW1SVG00HISENSE · HiULTRAwith ductless indoor unit AS-09UW1SVG**00Hisense1 ton9,000 Btu/h · Non-ducted1.8070%9.018.5CEE 25CEE 26XcelES CC1203377559
1644AS-09UW1SVG00AHISENSE · HiULTRAwith ductless indoor unit AS-09UW1SVG**00AHisense1 ton9,000 Btu/h · Non-ducted1.8070%9.018.5CEE 25CEE 26XcelES CC1205092755
1645AS-09UW3SXE00HISENSE · HiULTRAwith ductless indoor unit AS-09UW3SXE**00Hisense1 ton9,000 Btu/h · Non-ducted2.0589%10.527.5CEE 25CEE 26XcelES CC1201981253
1646AS-09UW3SXE00BHISENSEwith ductless indoor unit AS-09UW3SXE**00BHisense1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26Xcel1205092769
1647AS-09UW3SXETG00HISENSE · HiULTRAwith ductless indoor unit AS-09UW3SXETG00Hisense1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26XcelES CC1213803156
1648AS-09UW3SXETG00GHISENSE · HiULTRAwith ductless indoor unit AS-09UW3SXETG00Hisense1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26XcelES CC1213741353
1649AS-09UW3SXETG00PHISENSE · HiULTRAwith ductless indoor unit AS-09UW3SXETG00Hisense1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26XcelES CC1213741354
1650AS-12UR3SXA00HISENSE · HiULTRAwith ductless indoor unit AS-12UR3SXA**00Hisense1 ton12,000 Btu/h · Non-ducted1.7570%9.823.5CEE 25CEE 26XcelES CC610102525

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter