Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,739 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
38.1%
Qualifying models
3,739
Qualifying certifications
83,510
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F8,167 rated models · median 1.91At least 84% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50124
1.50 to under 1.6087
1.60 to under 1.70118
1.70 to under 1.80916
1.80 to under 1.902,176
1.90 to under 2.001,272
2.00 to under 2.101,285
2.10 to under 2.20613
2.20 to under 2.30484
2.30 to under 2.40356
2.40 to under 2.50165
2.50 to under 2.60114
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.91
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F8,157 rated models · median 69%48% of rated models reach 70% on this rating alone.
+32 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%68
35 to under 40%378
40 to under 45%216
45 to under 50%320
50 to under 55%640
55 to under 60%790
60 to under 65%964
65 to under 70%885
70 to under 75%1,102
75 to under 80%505
80 to under 85%543
85 to under 90%414
90 to under 95%386
95 to under 100%274
100 to under 105%389
105 to under 110%73
110 to under 115%81
115 to under 120%28
120 to under 125%46
125 to under 130%12
130% and above32
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,430 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5574
14.5 to under 15.0326
15.0 to under 15.5991
15.5 to under 16.0357
16.0 to under 16.5727
16.5 to under 17.0303
17.0 to under 17.5525
17.5 to under 18.0332
18.0 to under 18.5382
18.5 to under 19.0284
19.0 to under 19.5609
19.5 to under 20.0172
20.0 to under 20.5494
20.5 to under 21.0260
21.0 to under 21.5544
21.5 to under 22.0330
22.0 to under 22.5342
22.5 to under 23.0183
23.0 to under 23.5302
23.5 to under 24.0168
24.0 to under 24.5111
24.5 to under 25.056
25.0 to under 25.533
25.5 to under 26.055
26.0 to under 26.550
26.5 to under 27.037
27.0 to under 27.532
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,430 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+34 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5247
8.5 to under 9.0608
9.0 to under 9.5525
9.5 to under 10.0392
10.0 to under 10.5896
10.5 to under 11.01,192
11.0 to under 11.5995
11.5 to under 12.01,102
12.0 to under 12.5944
12.5 to under 13.01,269
13.0 to under 13.5576
13.5 to under 14.0231
14.0 to under 14.5128
14.5 to under 15.044
15.0 to under 15.597
15.5 to under 16.078
16.0 to under 16.568
16.5 and above34
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.6% · 1,748 of 3,201
2 tons46.9% · 682 of 1,454
2.5 to 3 tons31.5% · 830 of 2,633
3.5 to 4.5 tons20.7% · 449 of 2,174
5 tons and up8.3% · 30 of 362

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted21.1%970 / 4,608
Non-ducted43.5%1,444 / 3,317
Ducted and non-ducted69.8%1,325 / 1,899

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree242 of 40360%
Mitsubishi Electric206 of 40051.5%
Midea184 of 40845.1%
Lennox124 of 37533.1%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense101 of 16063.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 37114.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 79 of 150
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1951KSIE009-H221-O-2KLIMAIRE · KSI Serieswith ductless indoor unit KSIE009-H221-IW-2KLIMAIRE1 ton9,000 Btu/h · Ducted and non-ducted2.1180%11.424.0CEE 25CEE 26Xcel3209862149
1952KSIE012-H220-O-2KLIMAIRE · KSI Serieswith ductless indoor unit KTIR12-H2KLIMAIRE1 ton12,000 Btu/h · Ducted and non-ducted2.2867%10.022.7CEE 25CEE 26Xcel3209862158
1953KSIE018-H220-O-2KLIMAIRE · KSI Serieswith ducted air handler KDIP18-H2KLIMAIRE1.5 tons17,000 Btu/h · Ducted and non-ducted2.4065%10.620.0CEE 25CEE 26Xcel4209862162
1954KSIE024-H220-O-2KLIMAIRE · KSI Serieswith ducted air handler KDIP24-H2KLIMAIRE2 tons23,000 Btu/h · Ducted and non-ducted2.3080%11.219.0CEE 25CEE 26Xcel4209862163
1955KSIH009-H225-O-2KLIMAIRE · KSI Serieswith ductless indoor unit KSIH009-H225-IW-2KLIMAIRE1 ton9,000 Btu/h · Ducted and non-ducted1.9094%11.626.4CEE 25CEE 26Xcel3209862153
1956KSIH012-H222-O-2KLIMAIRE · KSI Serieswith ducted air handler KDIP12-H2KLIMAIRE1 ton12,000 Btu/h · Ducted and non-ducted1.9697%10.019.5CEE 25CEE 26Xcel3209862171
1957KSIH018-H220-O-2KLIMAIRE · KSI Serieswith ductless indoor unit KSIH018-H220-IW-2KLIMAIRE1.5 tons18,000 Btu/h · Ducted and non-ducted1.8996%10.622.0CEE 25CEE 26Xcel4209862155
1958KSIH024-H220-O-2KLIMAIRE · KSI Serieswith ductless indoor unit KUIR24-H2KLIMAIRE2 tons24,000 Btu/h · Ducted and non-ducted2.10100%11.020.5CEE 25CEE 26CEE AdvXcelDOE4209862174
1959KSIR048-H218-2KLIMAIRE · KSI Serieswith ductless indoor unit KTIS48-H2KLIMAIRE4 tons48,000 Btu/h · Ducted and non-ducted1.9869%9.818.5Xcel3212316047
1960LBH12AWOLBG Productswith ductless indoor unit LBH12AWILBG Products1 ton12,100 Btu/h · Non-ducted1.8474%9.025.0CEE 25CEE 26Xcel1206726729
1961LBH24DWOLBG Productswith ductless indoor unit LBH24DWILBG Products2 tons22,000 Btu/h · Non-ducted1.7583%8.520.0CEE 25CEE 26Xcel1206853247
1962LBHB06DVWOLBG Products · LBH serieswith ductless indoor unit LBHB06DVWILBG Products0.5 tons6,000 Btu/h · Non-ducted1.84101%12.023.5CEE 25CEE 26XcelES CC1208130826
1963LBHB09DROLBG Products · LBH serieswith ductless indoor unit LBHB09DRILBG Products1 ton9,000 Btu/h · Non-ducted2.1071%8.818.5CEE 25CEE 26XcelES CC1213614235
1964LBHB09DUWOLBG Products · LBH serieswith ductless indoor unit LBHB09DUWILBG Products1 ton9,000 Btu/h · Ducted and non-ducted2.2286%11.624.0CEE 25CEE 26XcelES CC3208130803
1965LBHB09DVWOLBG Products · LBH serieswith ductless indoor unit LBHB09DUWILBG Products1 ton9,000 Btu/h · Ducted and non-ducted1.9094%11.626.4CEE 25CEE 26XcelES CC3208130827
1966LBHB09DYWOLBG Products · LBH serieswith ductless indoor unit LBHB09DYWILBG Products1 ton9,000 Btu/h · Non-ducted1.86113%14.029.0CEE 25CEE 26XcelES CC1207629153
1967LBHB12DUWOLBG Products · LBH serieswith ductless indoor unit LMHB12DSILBG Products1 ton12,000 Btu/h · Ducted and non-ducted2.2767%10.022.7CEE 25CEE 26XcelES CC4208130808
1968LBHB12DVWOLBG Products · LBH serieswith ducted air handler LMHB12DFILBG Products1 ton12,000 Btu/h · Ducted and non-ducted1.96101%10.019.5CEE 25CEE 26XcelES CC4208130838
1969LBHB12DYWOLBG Products · LBH serieswith ductless indoor unit LBHB12DYWILBG Products1 ton12,000 Btu/h · Non-ducted1.86113%14.527.5CEE 25CEE 26XcelES CC1207629154
1970LBHB18DUWOLBG Products · LBH serieswith ducted air handler LMHB18DFILBG Products1.5 tons17,000 Btu/h · Ducted and non-ducted2.4065%10.620.0CEE 25CEE 26XcelES CC4208130815
1971LBHB18DVWOLBG Products · LBH serieswith ducted air handler LMHB18DFILBG Products1.5 tons17,000 Btu/h · Ducted and non-ducted1.8593%9.518.0CEE 25CEE 26XcelES CC4208130839
1972LBHB18DYWOLBG Products · LBH serieswith ductless indoor unit LBHB18DYWILBG Products2 tons24,000 Btu/h · Non-ducted1.8188%11.421.5CEE 25CEE 26XcelES CC1207629155
1973LBHB24DUWOLBG Products · LBH serieswith ducted air handler LMHB24DFILBG Products2 tons23,000 Btu/h · Ducted and non-ducted2.3081%11.219.0CEE 25CEE 26XcelES CC4208130816
1974LBHB24DVWOLBG Products · LBH serieswith ductless indoor unit LMHB24DZDILBG Products2 tons24,000 Btu/h · Ducted and non-ducted2.10102%11.020.5CEE 25CEE 26CEE AdvXcelDOEES CC4208130845
1975LCH24036DOLBG Productswith ducted air handler LCH24DGHNILBG Products2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26Xcel2206726718

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter