Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,653 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.7%
Qualifying models
3,653
Qualifying certifications
83,192
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,806 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50123
1.50 to under 1.6087
1.60 to under 1.70115
1.70 to under 1.80716
1.80 to under 1.902,089
1.90 to under 2.001,247
2.00 to under 2.101,265
2.10 to under 2.20607
2.20 to under 2.30477
2.30 to under 2.40345
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,798 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%366
40 to under 45%200
45 to under 50%286
50 to under 55%599
55 to under 60%783
60 to under 65%885
65 to under 70%799
70 to under 75%1,049
75 to under 80%488
80 to under 85%537
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%387
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,312 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.51,004
15.5 to under 16.0355
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5371
18.5 to under 19.0279
19.0 to under 19.5593
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,312 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,175
11.0 to under 11.5983
11.5 to under 12.01,096
12.0 to under 12.5918
12.5 to under 13.01,266
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,130
2 tons46.4% · 668 of 1,440
2.5–3 tons31.4% · 818 of 2,606
3.5–4.5 tons20.6% · 446 of 2,161
5 tons and up7.8% · 28 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.8%956 / 4,597
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,303 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Lennox121 of 37132.6%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 83 of 147
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2051LIZ036HO-210P432-1LENNOXLennox3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8290%10.021.0CEE 25CEE 26Xcel3209179150
2052LIZ042HO-210P432-1LENNOXLennox3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9281%10.021.0CEE 25CEE 26Xcel3209179153
2053MHB009S4S-1LLENNOX · M serieswith ductless indoor unit MWHB009S4-1LLennox1 ton9,000 Btu/h · Non-ducted2.1670%9.121.5CEE 25CEE 26XcelES CC3208106641
2054MHB009S4S-1PLENNOX · M serieswith ductless indoor unit MWHB009S4-1PLennox1 ton9,000 Btu/h · Non-ducted1.9970%9.421.7CEE 25CEE 26XcelES CC3208106643
2055ML17XP1-018-230A**LENNOXwith ducted air handler LEM264Lennox1.5 tons17,300 Btu/h · Ducted2.6758%8.215.0CEE 25CEE 26Xcel1,486211207052
2056ML17XP1-036-230A**LENNOXwith indoor coil CH48B34+TDR and furnace EL196DF090XE48CLennox2.5 tons32,800 Btu/h · Ducted2.7367%8.315.9CEE 25CEE 26Xcel2,349215038745
2057ML17XP1-048-230A**LENNOXwith ducted air handler LEM494Lennox3.5 tons44,000 Btu/h · Ducted2.8368%8.315.4CEE 25CEE 26Xcel1,927211207061
2058MLB009S4S-1PLENNOX · M serieswith ductless indoor unit MWMC009S4Lennox1 ton9,000 Btu/h · Ducted and non-ducted2.0088%11.528.1CEE 25CEE 26XcelES CC9210665627
2059MLB012S4S-1PLENNOX · M serieswith ducted air handler MMDB012S4Lennox1 ton11,800 Btu/h · Ducted and non-ducted1.9697%10.019.5CEE 25CEE 26XcelES CC12210665632
2060MLB018S4M-1PLENNOX · M seriesLennox1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9599%9.821.7CEE 25CEE 26XcelES CC3207768727
2061MLB018S4S-1PLENNOX · MMA serieswith ducted air handler MMA018SM4-*PLennox1.5 tons18,000 Btu/h · Ducted and non-ducted2.0096%9.617.6CEE 25CEE 26XcelES CC13212348049
2062MLB024S4S-1PLENNOX · M serieswith ductless indoor unit MWMC024S4-1PLennox2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC14207683523
2063MLB030S4M-1PLENNOX · M seriesLennox2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%10.623.0CEE 25CEE 26XcelES CC3207768730
2064MLB036S4M-1PLENNOX · M seriesLennox3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8199%10.322.2CEE 25CEE 26XcelES CC3207699104
2065MLB036S4S-2PLENNOXwith ducted air handler MMDB036S4-2PLennox3 tons36,000 Btu/h · Ducted and non-ducted2.12108%——XcelES CC10207699095
2066MLB048S4M-2PLENNOX · M seriesLennox4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%9.821.8CEE 25CEE 26XcelES CC3207699107
2067MPC009S4S-1PLENNOX · M serieswith ducted air handler MMDB009S4-*PLennox1 ton9,000 Btu/h · Ducted and non-ducted2.4085%10.019.2CEE 25CEE 26CEE AdvXcelDOEES CC11211034423
2068MPC012S4S-1PLENNOX · M serieswith ductless indoor unit MWMC012S4-1PLennox1 ton12,000 Btu/h · Ducted and non-ducted2.3967%10.724.6CEE 25CEE 26XcelES CC12207683498
2069MPC018S4M-1PLENNOX · M seriesLennox1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0370%9.819.0CEE 25CEE 26XcelES CC3207768722
2070MPC024S4M-1PLENNOX · M seriesLennox2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9984%8.616.0CEE 25CEE 26XcelES CC3207699117
2071MPC024S4S-1PLENNOX · M serieswith ducted air handler MMDB024S4-2PLennox2 tons23,000 Btu/h · Ducted and non-ducted2.3080%11.019.0CEE 25CEE 26XcelES CC13207683506
2072MPC048S4M-1PLENNOX · M seriesLennox4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8075%8.723.4CEE 25CEE 26Xcel3207699101
2073MPC048S4S-1PLENNOX · M serieswith ductless indoor unit M33C048S4-1PLennox4 tons47,000 Btu/h · Ducted and non-ducted1.9869%9.818.5XcelES CC9207683519
2074SL25XPV-024-230A**LENNOX · DAVE LENNOX SIGNATURE SL25XPV SERIESwith indoor coil CH35-42B+TDR+TXV and furnace SL280UH090V36BLennox2 tons22,800 Btu/h · Ducted1.9893%9.723.2CEE 25CEE 26XcelES CC145207436171
2075SL25XPV-036-230A**LENNOX · DAVE LENNOX SIGNATURE SL25XPV SERIESwith ducted air handler CBA38MV-036-230*+TDRLennox3 tons33,400 Btu/h · Ducted1.9274%9.122.0CEE 25CEE 26Xcel441207436328

Explore qualifying models by COP at 5°F