Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,653 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.7%
Qualifying models
3,653
Qualifying certifications
83,192
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,806 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50123
1.50 to under 1.6087
1.60 to under 1.70115
1.70 to under 1.80716
1.80 to under 1.902,089
1.90 to under 2.001,247
2.00 to under 2.101,265
2.10 to under 2.20607
2.20 to under 2.30477
2.30 to under 2.40345
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,798 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%366
40 to under 45%200
45 to under 50%286
50 to under 55%599
55 to under 60%783
60 to under 65%885
65 to under 70%799
70 to under 75%1,049
75 to under 80%488
80 to under 85%537
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%387
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,312 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.51,004
15.5 to under 16.0355
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5371
18.5 to under 19.0279
19.0 to under 19.5593
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,312 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,175
11.0 to under 11.5983
11.5 to under 12.01,096
12.0 to under 12.5918
12.5 to under 13.01,266
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,130
2 tons46.4% · 668 of 1,440
2.5–3 tons31.4% · 818 of 2,606
3.5–4.5 tons20.6% · 446 of 2,161
5 tons and up7.8% · 28 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.8%956 / 4,597
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,303 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Lennox121 of 37132.6%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 88 of 147
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2176L01-12K1V-19S-P-OLUORISEwith ductless indoor unit L01-12K1V-19S-WC-ILUORISE1 ton12,000 Btu/h · Non-ducted1.8070%8.519.0CEE 25CEE 26Xcel1214390714
2177L01-12K2V-19S-OLUORISEwith ductless indoor unit L01-12K2V-19S-WC-ILUORISE1 ton12,000 Btu/h · Non-ducted1.8070%8.519.0CEE 25CEE 26Xcel1214390719
2178L01-12K2V-19S-P-OLUORISEwith ductless indoor unit L01-12K2V-19S-WC-ILUORISE1 ton12,000 Btu/h · Non-ducted1.8070%8.519.0CEE 25CEE 26Xcel1214390718
2179DHX24CSB21SLUXAIRE BY JOHNSON CONTROLS · X serieswith ductless indoor unit DHX24NWB21SLUXAIRE BY JOHNSON CONTROLS2 tons22,000 Btu/h · Non-ducted1.7583%8.520.0CEE 25CEE 26Xcel18578583
2180TSA12MAQU1J0X24-OMaestralewith ductless indoor unit TSA12MAQU1J0X24-IMaestrale1 ton12,000 Btu/h · Non-ducted2.0570%9.523.5CEE 25CEE 26Xcel1216621477
2181TSA18MAQU1J0X24-OMaestralewith ductless indoor unit TSA18MAQU1J0X24-IMaestrale1.5 tons18,000 Btu/h · Non-ducted1.8670%9.520.5CEE 25CEE 26Xcel1216621478
2182TSB24MBOR3J0X24MaestraleMaestrale2 tons24,000 Btu/h · Non-ducted1.84100%9.122.0CEE 25CEE 26Xcel1217184744
2183TSB36MBOR4J0X24MaestraleMaestrale2.5 tons32,000 Btu/h · Non-ducted1.84100%9.021.0CEE 25CEE 26Xcel1217184745
2184MA-12CA22EXTMAESTROwith ductless indoor unit MA-12CA22INTMAESTRO1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel210277944
2185MA-12CA22SEXTMAESTROwith ductless indoor unit MA-12CA22SINTMAESTRO1 ton12,000 Btu/h · Non-ducted1.8580%9.521.0CEE 25CEE 26Xcel1205138202
2186MA-18CA22SEXTMAESTROwith ductless indoor unit MA-18CA22SINTMAESTRO1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26Xcel1205138203
2187GXH24-36MSK4DHMAMMOTH · Ultra Side Dischargewith ducted air handler GMH24-**MSK4DH1MAMMOTH2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26XcelES CC2206724412
2188GXH48-60MSK4DHMAMMOTH · Ultra Side Dischargewith ducted air handler GMH48-**MSK4DH1MAMMOTH4 tons48,000 Btu/h · Ducted1.8081%9.017.0CEE 25CEE 26XcelES CC2206724414
2189AS-09UR3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-09UR3SXEDJ(I)MANUFLOW1 ton9,000 Btu/h · Non-ducted2.1078%10.527.5CEE 25CEE 26Xcel110277956
2190AS-09UW3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-09UW3SXEDJ(I)MANUFLOW1 ton9,000 Btu/h · Non-ducted2.0589%10.527.5CEE 25CEE 26Xcel1202021915
2191AS-12UR3SXADJ(O)MANUFLOWwith ductless indoor unit AS-12UR3SXADJ(I)MANUFLOW1 ton12,000 Btu/h · Non-ducted1.7570%9.823.5CEE 25CEE 26Xcel110277957
2192AS-12UR3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-12UR3SXEDJ(I)MANUFLOW1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel110277943
2193AS-12UW3SXADJ(O)MANUFLOWwith ductless indoor unit AS-12UW3SXADJ(I)MANUFLOW1 ton12,000 Btu/h · Non-ducted1.9581%9.823.5CEE 25CEE 26Xcel1202021916
2194AST-09UW3SVGDJ01(I)MANUFLOWwith ductless indoor unit AST-09UW3SVGDJ01(O)MANUFLOW1 ton9,000 Btu/h · Non-ducted1.8070%9.022.0CEE 25CEE 26Xcel1203742098
2195AST-09UW3SVGDJ01(O)MANUFLOWwith ductless indoor unit AST-09UW3SVGDJ01(I)MANUFLOW1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel1203446796
2196AST-12UW3SXEDJ01(O)MANUFLOWwith ductless indoor unit AST-12UW3SXEDJ01(I)MANUFLOW1 ton12,000 Btu/h · Non-ducted1.7570%9.521.0CEE 25CEE 26Xcel1203446805
2197AST-18UW3SBBDJ00(O)MANUFLOWwith ductless indoor unit AST-18UW3SBBDJ00(I)MANUFLOW1.5 tons18,000 Btu/h · Non-ducted1.8777%8.622.5CEE 25CEE 26Xcel1203446797
2198AST-24UW3SDBDJ01(O)MANUFLOWwith ductless indoor unit AST-24UW3SDBDJ01(I)MANUFLOW2 tons23,000 Btu/h · Non-ducted2.1389%8.620.5CEE 25CEE 26Xcel1203446798
2199NE-T52-MHEAT3012EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3012IMAPLE HEAT1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC2215402352
2200NE-T52-MHEAT3018EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3018IMAPLE HEAT1.5 tons18,000 Btu/h · Non-ducted1.80100%11.321.5CEE 25CEE 26XcelES CC2215402351

Explore qualifying models by COP at 5°F