Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 3,653 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
37.7%
Qualifying models
3,653
Qualifying certifications
83,192
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F7,806 rated models · median 1.93At least 86% of rated models reach 1.75 on this rating alone.
+23 above37 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4037
1.40 to under 1.50123
1.50 to under 1.6087
1.60 to under 1.70115
1.70 to under 1.80716
1.80 to under 1.902,089
1.90 to under 2.001,247
2.00 to under 2.101,265
2.10 to under 2.20607
2.20 to under 2.30477
2.30 to under 2.40345
2.40 to under 2.50165
2.50 to under 2.60113
2.60 to under 2.70126
2.70 to under 2.8098
2.80 to under 2.9076
2.90 to under 3.0040
3.00 to under 3.1037
3.10 to under 3.2020
3.20 and above23
Baseline: median1.93
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F7,798 rated models · median 69%49% of rated models reach 70% on this rating alone.
+31 above11 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%11
30 to under 35%66
35 to under 40%366
40 to under 45%200
45 to under 50%286
50 to under 55%599
55 to under 60%783
60 to under 65%885
65 to under 70%799
70 to under 75%1,049
75 to under 80%488
80 to under 85%537
85 to under 90%414
90 to under 95%387
95 to under 100%270
100 to under 105%387
105 to under 110%74
110 to under 115%81
115 to under 120%27
120 to under 125%45
125 to under 130%13
130% and above31
Baseline: median69%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER29,312 rated models · median 17.5At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+34 above43 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 13.043
13.0 to under 13.5678
13.5 to under 14.022
14.0 to under 14.5570
14.5 to under 15.0317
15.0 to under 15.51,004
15.5 to under 16.0355
16.0 to under 16.5714
16.5 to under 17.0306
17.0 to under 17.5523
17.5 to under 18.0319
18.0 to under 18.5371
18.5 to under 19.0279
19.0 to under 19.5593
19.5 to under 20.0163
20.0 to under 20.5480
20.5 to under 21.0259
21.0 to under 21.5534
21.5 to under 22.0326
22.0 to under 22.5337
22.5 to under 23.0182
23.0 to under 23.5295
23.5 to under 24.0167
24.0 to under 24.5106
24.5 to under 25.055
25.0 to under 25.533
25.5 to under 26.056
26.0 to under 26.549
26.5 to under 27.037
27.0 to under 27.531
27.5 to under 28.026
28.0 to under 28.548
28.5 and above34
Baseline: median17.5
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER29,312 rated models · median 11.391% of rated models reach 9 (the lowest path) on this rating alone.
+33 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5244
8.5 to under 9.0584
9.0 to under 9.5515
9.5 to under 10.0388
10.0 to under 10.5900
10.5 to under 11.01,175
11.0 to under 11.5983
11.5 to under 12.01,096
12.0 to under 12.5918
12.5 to under 13.01,266
13.0 to under 13.5568
13.5 to under 14.0228
14.0 to under 14.5126
14.5 to under 15.044
15.0 to under 15.595
15.5 to under 16.077
16.0 to under 16.568
16.5 and above33
Baseline: median11.3
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons54.1% · 1,693 of 3,130
2 tons46.4% · 668 of 1,440
2.5–3 tons31.4% · 818 of 2,606
3.5–4.5 tons20.6% · 446 of 2,161
5 tons and up7.8% · 28 of 358

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted20.8%956 / 4,597
Non-ducted43.1%1,394 / 3,236
Ducted and non-ducted70%1,303 / 1,862

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree223 of 39556.5%
Mitsubishi Electric200 of 37353.6%
Midea180 of 40244.8%
Lennox121 of 37132.6%
Carrier120 of 70117.1%
Rheem102 of 29135.1%
Hisense94 of 15959.1%
Trane68 of 30922%
Fujitsu56 of 16434.1%
Daikin55 of 36715%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 89 of 147
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2201COU-D30HNR1-D01-J0MAXI AIRwith ducted air handler F45-SPLTAH36MAXI AIR2.5 tons30,000 Btu/h · Ducted1.8876%7.817.5Xcel2212940829
2202MAXS-2430MAXI AIRwith ducted air handler NE-F52-MAC36HWDMAXI AIR2.5 tons30,000 Btu/h · Ducted1.8582%9.715.5CEE 25CEE 26XcelES CC4213265613
2203NE-T52-PLA12INTMAXI AIR · NE serieswith ductless indoor unit NE-T52-PLA12EXTMAXI AIR1 ton12,000 Btu/h · Non-ducted2.0970%9.323.1CEE 25CEE 26Xcel2212348361
2204NE-T52-PLA18INTMAXI AIR · NE serieswith ductless indoor unit NE-T52-PLA18EXTMAXI AIR1.5 tons18,000 Btu/h · Non-ducted2.3870%10.323.7CEE 25CEE 26XcelES CC2212348364
2205NE-T52-SUPAE12EMAXI AIR · NE serieswith ductless indoor unit NE-T52-SUPAE12IMAXI AIR1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC2212348360
2206NE-T52-SUPAE18EMAXI AIR · NE serieswith ductless indoor unit NE-T52-SUPAE18IMAXI AIR1.5 tons18,000 Btu/h · Non-ducted1.80100%11.321.5CEE 25CEE 26XcelES CC2212348362
2207NE-T53-AEG12EXTMAXI AIR · NE serieswith ductless indoor unit NE-T53-AEG12INTMAXI AIR1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC2213927611
2208NE-T53-AEG18EXTMAXI AIR · NE serieswith ductless indoor unit NE-T53-AEG18INTMAXI AIR1.5 tons18,000 Btu/h · Non-ducted1.80100%11.321.5CEE 25CEE 26XcelES CC2213927612
2209NE-T53-MULTI28EMAXI AIR · NE seriesMAXI AIR2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%10.623.0CEE 25CEE 26Xcel3213927619
2210NE-T53-MULTI28E*MAXI AIR · NE seriesMAXI AIR2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%10.623.0CEE 25CEE 26XcelES CC3217754293
2211NE-T53-MULTI36EMAXI AIR · NE seriesMAXI AIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%10.322.2CEE 25CEE 26Xcel3213927622
2212NE-T53-MULTI36E*MAXI AIR · NE seriesMAXI AIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%10.322.2CEE 25CEE 26XcelES CC3217754296
2213YS21F-12HRDN1MAXI AIR · YS serieswith ductless indoor unit YS21F-12HRDN1MAXI AIR1 ton12,000 Btu/h · Non-ducted2.0970%9.323.1CEE 25CEE 26Xcel2203238009
2214YS21F-18HRDN1MAXI AIR · YS serieswith ductless indoor unit YS21F-18HRDN1MAXI AIR1.5 tons18,000 Btu/h · Non-ducted2.3870%10.323.7CEE 25CEE 26XcelES CC2203238010
2215CLASS24CCMAXI AIR CENTRALwith ducted air handler AHAN2410MAXI AIR CENTRAL2 tons22,000 Btu/h · Ducted1.8370%8.517.8CEE 25CEE 26Xcel2206799638
2216CLASS30CCMAXI AIR CENTRALwith ducted air handler AHAN3615MAXI AIR CENTRAL2.5 tons30,000 Btu/h · Ducted1.8876%7.817.5Xcel3210372390
221738MARBQ06AA3MIDEA · 38MAR-serieswith ductless indoor unit DHMAHBQ06XA3Midea0.5 tons6,000 Btu/h · Non-ducted2.09107%13.626.5CEE 25CEE 26XcelES CC2207188936
221838MARBQ09AA3MIDEA · 38MAR-serieswith ductless indoor unit DHMAHBQ09XA3Midea1 ton9,000 Btu/h · Ducted and non-ducted1.9788%11.528.1CEE 25CEE 26XcelES CC6206350318
221938MARBQ12AA3MIDEA · 38MAR-serieswith ductless indoor unit 40MBFAQ12XA3Midea1 ton12,000 Btu/h · Ducted and non-ducted1.9999%10.724.2CEE 25CEE 26XcelES CC8209948190
222038MARBQ18AA3MIDEA · 38MAR-serieswith ducted air handler 40MBDAQ18XH3Midea1.5 tons17,500 Btu/h · Ducted and non-ducted2.2095%10.818.0CEE 25CEE 26XcelES CC9211132964
222138MARBQ24AA3MIDEA · 38MAR-serieswith ductless indoor unit DHMAHBQ24XA3Midea2 tons24,000 Btu/h · Ducted and non-ducted2.2186%11.421.5CEE 25CEE 26CEE AdvXcelDOEES CC7206350321
222238MBRCQ48AA3MIDEA · 38MB-serieswith ductless indoor unit 40MBCAQ48XA3Midea4 tons48,000 Btu/h · Ducted and non-ducted1.9869%9.818.5XcelES CC5207683317
222338MBRQ48A--3MIDEAwith ductless indoor unit 40MBCQ48---3Midea4 tons48,000 Btu/h · Ducted and non-ducted2.0376%9.016.8Xcel3201847058
222438MGHBQ24CA3MIDEA · 38MG-seriesMidea2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9074%10.024.6CEE 25CEE 26XcelES CC3207642963
222538MGHBQ30DA3MIDEA · 38MG-seriesMidea2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8084%9.826.0CEE 25CEE 26XcelES CC3207642966

Explore qualifying models by COP at 5°F